Net Ultimate Bearing Capacity given Net Safe Bearing Capacity Formula

Fx Copy
LaTeX Copy
Net Ultimate Bearing Capacity is the maximum load per unit area that a soil can withstand without failure under the conditions imposed by the presence of groundwater. Check FAQs
qnet'=qnsaFOS
qnet' - Net Ultimate Bearing Capacity?qnsa - Net Safe Bearing Capacity in Soil?FOS - Factor of Safety in Bearing Capacity of Soil?

Net Ultimate Bearing Capacity given Net Safe Bearing Capacity Example

With values
With units
Only example

Here is how the Net Ultimate Bearing Capacity given Net Safe Bearing Capacity equation looks like with Values.

Here is how the Net Ultimate Bearing Capacity given Net Safe Bearing Capacity equation looks like with Units.

Here is how the Net Ultimate Bearing Capacity given Net Safe Bearing Capacity equation looks like.

5.292Edit=1.89Edit2.8Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Net Ultimate Bearing Capacity given Net Safe Bearing Capacity

Net Ultimate Bearing Capacity given Net Safe Bearing Capacity Solution

Follow our step by step solution on how to calculate Net Ultimate Bearing Capacity given Net Safe Bearing Capacity?

FIRST Step Consider the formula
qnet'=qnsaFOS
Next Step Substitute values of Variables
qnet'=1.89kN/m²2.8
Next Step Convert Units
qnet'=1890Pa2.8
Next Step Prepare to Evaluate
qnet'=18902.8
Next Step Evaluate
qnet'=5292Pa
LAST Step Convert to Output's Unit
qnet'=5.292kN/m²

Net Ultimate Bearing Capacity given Net Safe Bearing Capacity Formula Elements

Variables
Net Ultimate Bearing Capacity
Net Ultimate Bearing Capacity is the maximum load per unit area that a soil can withstand without failure under the conditions imposed by the presence of groundwater.
Symbol: qnet'
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Net Safe Bearing Capacity in Soil
Net Safe Bearing Capacity in Soil is the net ultimate bearing capacity divided by factor of safety.
Symbol: qnsa
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Factor of Safety in Bearing Capacity of Soil
Factor of Safety in Bearing Capacity of Soil expresses how much stronger a soil is than it needs to be for an intended load.
Symbol: FOS
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Bearing Capacity of Soils category

​Go Ultimate Bearing Capacity of Soil under Long Footing at Surface of Soil
qf=((Ctan(Φi))+(0.5γdBKP)(KPexp(πtan(Φi))-1))
​Go Effective Surcharge given Depth of Footing
σs=γD
​Go Ultimate Bearing Capacity
qf=qnet+σs
​Go Net Ultimate Bearing Capacity given Ultimate Bearing Capacity
qnet=qf-σs

How to Evaluate Net Ultimate Bearing Capacity given Net Safe Bearing Capacity?

Net Ultimate Bearing Capacity given Net Safe Bearing Capacity evaluator uses Net Ultimate Bearing Capacity = Net Safe Bearing Capacity in Soil*Factor of Safety in Bearing Capacity of Soil to evaluate the Net Ultimate Bearing Capacity, The Net Ultimate Bearing Capacity given Net Safe Bearing Capacity formula is defined as the maximum load that can be applied to the foundation soil without causing failure. This is typically determined through extensive testing and analysis of soil samples under controlled conditions to understand its load-bearing capacity. Net Ultimate Bearing Capacity is denoted by qnet' symbol.

How to evaluate Net Ultimate Bearing Capacity given Net Safe Bearing Capacity using this online evaluator? To use this online evaluator for Net Ultimate Bearing Capacity given Net Safe Bearing Capacity, enter Net Safe Bearing Capacity in Soil (qnsa) & Factor of Safety in Bearing Capacity of Soil (FOS) and hit the calculate button.

FAQs on Net Ultimate Bearing Capacity given Net Safe Bearing Capacity

What is the formula to find Net Ultimate Bearing Capacity given Net Safe Bearing Capacity?
The formula of Net Ultimate Bearing Capacity given Net Safe Bearing Capacity is expressed as Net Ultimate Bearing Capacity = Net Safe Bearing Capacity in Soil*Factor of Safety in Bearing Capacity of Soil. Here is an example- 0.005292 = 1890*2.8.
How to calculate Net Ultimate Bearing Capacity given Net Safe Bearing Capacity?
With Net Safe Bearing Capacity in Soil (qnsa) & Factor of Safety in Bearing Capacity of Soil (FOS) we can find Net Ultimate Bearing Capacity given Net Safe Bearing Capacity using the formula - Net Ultimate Bearing Capacity = Net Safe Bearing Capacity in Soil*Factor of Safety in Bearing Capacity of Soil.
Can the Net Ultimate Bearing Capacity given Net Safe Bearing Capacity be negative?
No, the Net Ultimate Bearing Capacity given Net Safe Bearing Capacity, measured in Pressure cannot be negative.
Which unit is used to measure Net Ultimate Bearing Capacity given Net Safe Bearing Capacity?
Net Ultimate Bearing Capacity given Net Safe Bearing Capacity is usually measured using the Kilonewton per Square Meter[kN/m²] for Pressure. Pascal[kN/m²], Kilopascal[kN/m²], Bar[kN/m²] are the few other units in which Net Ultimate Bearing Capacity given Net Safe Bearing Capacity can be measured.
Copied!