Fx Copy
LaTeX Copy
Negative Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Check FAQs
V2=EaZ2Z1+Z2
V2 - Negative Sequence Voltage?Ea - A Phase EMF?Z2 - Negative Sequence Impedance?Z1 - Positive Sequence Impedance?

Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) Example

With values
With units
Only example

Here is how the Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) equation looks like with Values.

Here is how the Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) equation looks like with Units.

Here is how the Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) equation looks like.

35.7433Edit=29.38Edit-44.6Edit7.94Edit+-44.6Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)

Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) Solution

Follow our step by step solution on how to calculate Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)?

FIRST Step Consider the formula
V2=EaZ2Z1+Z2
Next Step Substitute values of Variables
V2=29.38V-44.6Ω7.94Ω+-44.6Ω
Next Step Prepare to Evaluate
V2=29.38-44.67.94+-44.6
Next Step Evaluate
V2=35.7432624113475V
LAST Step Rounding Answer
V2=35.7433V

Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) Formula Elements

Variables
Negative Sequence Voltage
Negative Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: V2
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
A Phase EMF
A phase EMF is defined as the electromagnetic force of the a-phase in open conductor fault.
Symbol: Ea
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Negative Sequence Impedance
Negative Sequence Impedance consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: Z2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Positive Sequence Impedance
Positive Sequence Impedance consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: Z1
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Negative Sequence Voltage

​Go Negative Sequence Voltage (LLF)
V2=V1-(ZfI1)

Other formulas in Voltage and EMF category

​Go B-Phase Voltage (LLF)
Vb=(ZfIb)+Vc
​Go C-Phase Voltage (LLF)
Vc=Vb-(ZfIb)
​Go C-Phase Voltage using C-Phase Current (LLF)
Vc=Vb+(ZfIc)
​Go B-Phase Voltage using C-Phase Current (LLF)
Vb=Vc-(ZfIc)

How to Evaluate Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)?

Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) evaluator uses Negative Sequence Voltage = (A Phase EMF*Negative Sequence Impedance)/(Positive Sequence Impedance+Negative Sequence Impedance) to evaluate the Negative Sequence Voltage, The Negative Sequence Voltage using A-phase EMF and Sequence Impedances(LLF) formula is defined as the voltage that is present in one phase of a three-phase electrical power system with respect to the negative sequence components of the system. Negative Sequence Voltage is denoted by V2 symbol.

How to evaluate Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) using this online evaluator? To use this online evaluator for Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF), enter A Phase EMF (Ea), Negative Sequence Impedance (Z2) & Positive Sequence Impedance (Z1) and hit the calculate button.

FAQs on Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)

What is the formula to find Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)?
The formula of Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) is expressed as Negative Sequence Voltage = (A Phase EMF*Negative Sequence Impedance)/(Positive Sequence Impedance+Negative Sequence Impedance). Here is an example- 24.94001 = (29.38*(-44.6))/(7.94+(-44.6)).
How to calculate Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)?
With A Phase EMF (Ea), Negative Sequence Impedance (Z2) & Positive Sequence Impedance (Z1) we can find Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) using the formula - Negative Sequence Voltage = (A Phase EMF*Negative Sequence Impedance)/(Positive Sequence Impedance+Negative Sequence Impedance).
What are the other ways to Calculate Negative Sequence Voltage?
Here are the different ways to Calculate Negative Sequence Voltage-
  • Negative Sequence Voltage=Positive Sequence Voltage-(Fault Impedance*Positive Sequence Current)OpenImg
Can the Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) be negative?
Yes, the Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF), measured in Electric Potential can be negative.
Which unit is used to measure Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF)?
Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Negative Sequence Voltage using A-Phase EMF and Sequence Impedances(LLF) can be measured.
Copied!