Fx Copy
LaTeX Copy
Saturation Voltage is a condition where the output of the trigger remains low even when the input voltage is above the lower threshold voltage. Check FAQs
Vsat=-Vee+Vdrop
Vsat - Saturation Voltage?Vee - Emitter Voltage?Vdrop - Small Voltage Drop?

Negative Saturation Voltage of Srchmitt Trigger Example

With values
With units
Only example

Here is how the Negative Saturation Voltage of Srchmitt Trigger equation looks like with Values.

Here is how the Negative Saturation Voltage of Srchmitt Trigger equation looks like with Units.

Here is how the Negative Saturation Voltage of Srchmitt Trigger equation looks like.

1.2Edit=-0.7Edit+1.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Integrated Circuits (IC) » fx Negative Saturation Voltage of Srchmitt Trigger

Negative Saturation Voltage of Srchmitt Trigger Solution

Follow our step by step solution on how to calculate Negative Saturation Voltage of Srchmitt Trigger?

FIRST Step Consider the formula
Vsat=-Vee+Vdrop
Next Step Substitute values of Variables
Vsat=-0.7V+1.9V
Next Step Prepare to Evaluate
Vsat=-0.7+1.9
LAST Step Evaluate
Vsat=1.2V

Negative Saturation Voltage of Srchmitt Trigger Formula Elements

Variables
Saturation Voltage
Saturation Voltage is a condition where the output of the trigger remains low even when the input voltage is above the lower threshold voltage.
Symbol: Vsat
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Emitter Voltage
Emitter Voltage is one of the three terminals of a BJT, along with the base and collector. When the emitter is forward biased.
Symbol: Vee
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Small Voltage Drop
A Small Voltage Drop is an operational amplifier that has a very small voltage drop between its input and output terminals.
Symbol: Vdrop
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Saturation Voltage

​Go Positive Saturation Voltage of Schmitt Trigger
Vsat=+Vcc-Vdrop

Other formulas in Schmitt Trigger category

​Go Input Current of Schmitt Trigger
in=VinRin
​Go Lower Threshold Voltage of Inverting Schmitt Trigger
Vf=-Vsat(R2R1+R2)
​Go Open Loop Gain of Schmitt Trigger
Av=VfiV+-V-
​Go Lower Threshold Voltage of Non Inverting Schmitt Trigger
Vlt=-Vsat(R2R1)

How to Evaluate Negative Saturation Voltage of Srchmitt Trigger?

Negative Saturation Voltage of Srchmitt Trigger evaluator uses Saturation Voltage = -Emitter Voltage+Small Voltage Drop to evaluate the Saturation Voltage, The Negative Saturation Voltage of Srchmitt Trigger is limited by the internal circuitry of the op-amp. When the op-amp tries to output a voltage lower than its negative saturation voltage, it cannot provide enough current to drive the output stage. Saturation Voltage is denoted by Vsat symbol.

How to evaluate Negative Saturation Voltage of Srchmitt Trigger using this online evaluator? To use this online evaluator for Negative Saturation Voltage of Srchmitt Trigger, enter Emitter Voltage (Vee) & Small Voltage Drop (Vdrop) and hit the calculate button.

FAQs on Negative Saturation Voltage of Srchmitt Trigger

What is the formula to find Negative Saturation Voltage of Srchmitt Trigger?
The formula of Negative Saturation Voltage of Srchmitt Trigger is expressed as Saturation Voltage = -Emitter Voltage+Small Voltage Drop. Here is an example- 5.9 = -0.7+1.9.
How to calculate Negative Saturation Voltage of Srchmitt Trigger?
With Emitter Voltage (Vee) & Small Voltage Drop (Vdrop) we can find Negative Saturation Voltage of Srchmitt Trigger using the formula - Saturation Voltage = -Emitter Voltage+Small Voltage Drop.
What are the other ways to Calculate Saturation Voltage?
Here are the different ways to Calculate Saturation Voltage-
  • Saturation Voltage=+Supply Voltage of Op Amp-Small Voltage DropOpenImg
Can the Negative Saturation Voltage of Srchmitt Trigger be negative?
No, the Negative Saturation Voltage of Srchmitt Trigger, measured in Electric Potential cannot be negative.
Which unit is used to measure Negative Saturation Voltage of Srchmitt Trigger?
Negative Saturation Voltage of Srchmitt Trigger is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Negative Saturation Voltage of Srchmitt Trigger can be measured.
Copied!