Negative Sequence Current is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Check FAQs
I2=3V2Zd
I2 - Negative Sequence Current?V2 - Negative Sequence Voltage?Zd - Delta Impedance?

Negative Phase Current for Delta Connected Load Example

With values
With units
Only example

Here is how the Negative Phase Current for Delta Connected Load equation looks like with Values.

Here is how the Negative Phase Current for Delta Connected Load equation looks like with Units.

Here is how the Negative Phase Current for Delta Connected Load equation looks like.

-0.4667Edit=3-1.4Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Negative Phase Current for Delta Connected Load

Negative Phase Current for Delta Connected Load Solution

Follow our step by step solution on how to calculate Negative Phase Current for Delta Connected Load?

FIRST Step Consider the formula
I2=3V2Zd
Next Step Substitute values of Variables
I2=3-1.4V9Ω
Next Step Prepare to Evaluate
I2=3-1.49
Next Step Evaluate
I2=-0.466666666666667A
LAST Step Rounding Answer
I2=-0.4667A

Negative Phase Current for Delta Connected Load Formula Elements

Variables
Negative Sequence Current
Negative Sequence Current is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: I2
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Negative Sequence Voltage
Negative Sequence Voltage is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: V2
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Delta Impedance
Delta Impedance is defined as the impedance of delta connected network.
Symbol: Zd
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Negative Sequence Current

​Go Negative Sequence Current for Star Connected Load
I2=V2Zy

Other formulas in Sequence Current and Voltage category

​Go Negative Sequence Voltage for Star Connected Load
V2=I2Zy
​Go Zero Sequence Voltage for Star Connected Load
V0=(Zy+3Zf)I0
​Go Positive Sequence Voltage for Delta Connected Load
V1=ZdI13
​Go Positive Sequence Voltage for Star Connected Load
V1=ZyI1

How to Evaluate Negative Phase Current for Delta Connected Load?

Negative Phase Current for Delta Connected Load evaluator uses Negative Sequence Current = (3*Negative Sequence Voltage)/Delta Impedance to evaluate the Negative Sequence Current, The Negative Phase Current for Delta Connected Load formula is defined as The negative sequence consisting of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Negative Sequence Current is denoted by I2 symbol.

How to evaluate Negative Phase Current for Delta Connected Load using this online evaluator? To use this online evaluator for Negative Phase Current for Delta Connected Load, enter Negative Sequence Voltage (V2) & Delta Impedance (Zd) and hit the calculate button.

FAQs on Negative Phase Current for Delta Connected Load

What is the formula to find Negative Phase Current for Delta Connected Load?
The formula of Negative Phase Current for Delta Connected Load is expressed as Negative Sequence Current = (3*Negative Sequence Voltage)/Delta Impedance. Here is an example- -0.466667 = (3*(-1.4))/9.
How to calculate Negative Phase Current for Delta Connected Load?
With Negative Sequence Voltage (V2) & Delta Impedance (Zd) we can find Negative Phase Current for Delta Connected Load using the formula - Negative Sequence Current = (3*Negative Sequence Voltage)/Delta Impedance.
What are the other ways to Calculate Negative Sequence Current?
Here are the different ways to Calculate Negative Sequence Current-
  • Negative Sequence Current=Negative Sequence Voltage/Star ImpedanceOpenImg
Can the Negative Phase Current for Delta Connected Load be negative?
Yes, the Negative Phase Current for Delta Connected Load, measured in Electric Current can be negative.
Which unit is used to measure Negative Phase Current for Delta Connected Load?
Negative Phase Current for Delta Connected Load is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Negative Phase Current for Delta Connected Load can be measured.
Copied!