Fx Copy
LaTeX Copy
Murphree Efficiency of Absorption Column is defined for each tray according to the separation achieved on each tray based on either the liquid phase or the vapor phase. Check FAQs
EMG=(A(exp(EOGA100)-1))100
EMG - Murphree Efficiency of Absorption Column?A - Absorption Factor?EOG - Point Efficiency of Absorption Column in Percent?

Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow Example

With values
With units
Only example

Here is how the Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow equation looks like with Values.

Here is how the Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow equation looks like with Units.

Here is how the Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow equation looks like.

90.9983Edit=(2Edit(exp(75Edit2Edit100)-1))100
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow

Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow Solution

Follow our step by step solution on how to calculate Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow?

FIRST Step Consider the formula
EMG=(A(exp(EOGA100)-1))100
Next Step Substitute values of Variables
EMG=(2(exp(752100)-1))100
Next Step Prepare to Evaluate
EMG=(2(exp(752100)-1))100
Next Step Evaluate
EMG=90.9982829236402
LAST Step Rounding Answer
EMG=90.9983

Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow Formula Elements

Variables
Functions
Murphree Efficiency of Absorption Column
Murphree Efficiency of Absorption Column is defined for each tray according to the separation achieved on each tray based on either the liquid phase or the vapor phase.
Symbol: EMG
Measurement: NAUnit: Unitless
Note: Value should be less than 100.
Absorption Factor
The Absorption Factor is the ratio of slopes of operating line of absorption to the equilibrium line. If equilibrium line is a curve then the absorption factor is the average at the two ends.
Symbol: A
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Point Efficiency of Absorption Column in Percent
The Point Efficiency of Absorption Column in percent based on the vapor phase is the gas liquid separation efficiency on each tray for liquid vertically well mixed and gas in plug flow.
Symbol: EOG
Measurement: NAUnit: Unitless
Note: Value should be less than 100.
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other Formulas to find Murphree Efficiency of Absorption Column

​Go Murphree Tray Efficiency of Absorption Operation
EMG=(yn-yn+1yn*-yn+1)100

Other formulas in Gas Absorption and Stripping category

​Go Number of Stripping Stages by Kremser Equation
N=log10((X0(Stripping)-(YN+1(Stripping)α)XN(Stripping)-(YN+1(Stripping)α))(1-(1S))+(1S))log10(S)
​Go Stripping Factor
S=αGs(Stripping)Ls(Stripping)
​Go Stripping Factor given Absorption Factor
S=1A
​Go Absorption Factor
A=LsαGs

How to Evaluate Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow?

Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow evaluator uses Murphree Efficiency of Absorption Column = (Absorption Factor*(exp(Point Efficiency of Absorption Column in Percent/(Absorption Factor*100))-1))*100 to evaluate the Murphree Efficiency of Absorption Column, The Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow formula is defined as tray efficiency of absorption for no axial mixing flow. Murphree Efficiency of Absorption Column is denoted by EMG symbol.

How to evaluate Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow using this online evaluator? To use this online evaluator for Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow, enter Absorption Factor (A) & Point Efficiency of Absorption Column in Percent (EOG) and hit the calculate button.

FAQs on Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow

What is the formula to find Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow?
The formula of Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow is expressed as Murphree Efficiency of Absorption Column = (Absorption Factor*(exp(Point Efficiency of Absorption Column in Percent/(Absorption Factor*100))-1))*100. Here is an example- 90.99828 = (2*(exp(75/(2*100))-1))*100.
How to calculate Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow?
With Absorption Factor (A) & Point Efficiency of Absorption Column in Percent (EOG) we can find Murphree Efficiency of Absorption Operation Based on Point Efficiency for Plug Flow using the formula - Murphree Efficiency of Absorption Column = (Absorption Factor*(exp(Point Efficiency of Absorption Column in Percent/(Absorption Factor*100))-1))*100. This formula also uses Exponential Growth (exp) function(s).
What are the other ways to Calculate Murphree Efficiency of Absorption Column?
Here are the different ways to Calculate Murphree Efficiency of Absorption Column-
  • Murphree Efficiency of Absorption Column=((Average Mole Fraction of Vapour on Nth Plate-Average Mole Fraction of Vapour at N+1 Plate)/(Average Mole Fraction at Equilibrium on Nth Plate-Average Mole Fraction of Vapour at N+1 Plate))*100OpenImg
Copied!