Fx Copy
LaTeX Copy
Multiplier Resistance is the value of series resistance attached to the pmmc-based voltmeter. Check FAQs
Rs=VrmsSdc-Rh-Rd
Rs - Multiplier Resistance?Vrms - Voltage RMS Value?Sdc - DC Meter Sensitivity?Rh - Half Wave Shunt Meter Resistance?Rd - Diode Resistance?

Multiplier Resistance for DC Operation Half Wave Rectifier Example

With values
With units
Only example

Here is how the Multiplier Resistance for DC Operation Half Wave Rectifier equation looks like with Values.

Here is how the Multiplier Resistance for DC Operation Half Wave Rectifier equation looks like with Units.

Here is how the Multiplier Resistance for DC Operation Half Wave Rectifier equation looks like.

16.535Edit=7.07Edit8.6Edit-43.517Edit-0.75Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Multiplier Resistance for DC Operation Half Wave Rectifier

Multiplier Resistance for DC Operation Half Wave Rectifier Solution

Follow our step by step solution on how to calculate Multiplier Resistance for DC Operation Half Wave Rectifier?

FIRST Step Consider the formula
Rs=VrmsSdc-Rh-Rd
Next Step Substitute values of Variables
Rs=7.07V8.6Ω/V-43.517Ω-0.75Ω
Next Step Prepare to Evaluate
Rs=7.078.6-43.517-0.75
LAST Step Evaluate
Rs=16.535Ω

Multiplier Resistance for DC Operation Half Wave Rectifier Formula Elements

Variables
Multiplier Resistance
Multiplier Resistance is the value of series resistance attached to the pmmc-based voltmeter.
Symbol: Rs
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Voltage RMS Value
Voltage RMS Value is the effective value of an alternating voltage, representing the equivalent direct current (DC) voltage that would produce the same power dissipation in a resistive load.
Symbol: Vrms
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
DC Meter Sensitivity
DC Meter Sensitivity refers to the ability of a DC measuring instrument to detect and accurately measure small direct current (DC) voltages or currents.
Symbol: Sdc
Measurement: Meter SensitivityUnit: Ω/V
Note: Value should be greater than 0.
Half Wave Shunt Meter Resistance
Half Wave Shunt Meter Resistance is the value of Shunt Meter resistance connected parallel to each other attached to the permanent magnet moving coil-based voltmeter.
Symbol: Rh
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Diode Resistance
Diode Resistance refers to the resistance a diode presents to the flow of electric current.
Symbol: Rd
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Multiplier Resistance

​Go Multiplier Resistance for DC Operation Full Wave Rectifier
Rs=VrmsSdc-Rf-2Rd
​Go Multiplier Resistance for AC Operation Half Wave Rectifier
Rs=VrmsSac-Rh-Rd
​Go Multiplier Resistance for AC Operation Full Wave Rectifier
Rs=VrmsSac-Rf-2Rd

Other formulas in Rectifier Type Voltmeter category

​Go AC Voltage
V=Vpsin(ωt)
​Go Vrms value
Vrms=Vp2
​Go Average Voltage of Half Wave Rectifier
Vh=0.45Vrms
​Go Average Voltage of Full Wave Rectifier
Vf=0.9Vrms

How to Evaluate Multiplier Resistance for DC Operation Half Wave Rectifier?

Multiplier Resistance for DC Operation Half Wave Rectifier evaluator uses Multiplier Resistance = Voltage RMS Value*DC Meter Sensitivity-Half Wave Shunt Meter Resistance-Diode Resistance to evaluate the Multiplier Resistance, The Multiplier Resistance for DC Operation Half Wave Rectifier formula is defined as the series resistor used to extend the voltage range of the rectifier circuit by limiting the current flow to the rectifier and the load. Multiplier Resistance is denoted by Rs symbol.

How to evaluate Multiplier Resistance for DC Operation Half Wave Rectifier using this online evaluator? To use this online evaluator for Multiplier Resistance for DC Operation Half Wave Rectifier, enter Voltage RMS Value (Vrms), DC Meter Sensitivity (Sdc), Half Wave Shunt Meter Resistance (Rh) & Diode Resistance (Rd) and hit the calculate button.

FAQs on Multiplier Resistance for DC Operation Half Wave Rectifier

What is the formula to find Multiplier Resistance for DC Operation Half Wave Rectifier?
The formula of Multiplier Resistance for DC Operation Half Wave Rectifier is expressed as Multiplier Resistance = Voltage RMS Value*DC Meter Sensitivity-Half Wave Shunt Meter Resistance-Diode Resistance. Here is an example- 19.363 = 7.07*8.6-43.517-0.75.
How to calculate Multiplier Resistance for DC Operation Half Wave Rectifier?
With Voltage RMS Value (Vrms), DC Meter Sensitivity (Sdc), Half Wave Shunt Meter Resistance (Rh) & Diode Resistance (Rd) we can find Multiplier Resistance for DC Operation Half Wave Rectifier using the formula - Multiplier Resistance = Voltage RMS Value*DC Meter Sensitivity-Half Wave Shunt Meter Resistance-Diode Resistance.
What are the other ways to Calculate Multiplier Resistance?
Here are the different ways to Calculate Multiplier Resistance-
  • Multiplier Resistance=Voltage RMS Value*DC Meter Sensitivity-Full Wave Shunt Meter Resistance-2*Diode ResistanceOpenImg
  • Multiplier Resistance=Voltage RMS Value*AC Meter Sensitivity-Half Wave Shunt Meter Resistance-Diode ResistanceOpenImg
  • Multiplier Resistance=Voltage RMS Value*AC Meter Sensitivity-Full Wave Shunt Meter Resistance-2*Diode ResistanceOpenImg
Can the Multiplier Resistance for DC Operation Half Wave Rectifier be negative?
No, the Multiplier Resistance for DC Operation Half Wave Rectifier, measured in Electric Resistance cannot be negative.
Which unit is used to measure Multiplier Resistance for DC Operation Half Wave Rectifier?
Multiplier Resistance for DC Operation Half Wave Rectifier is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Multiplier Resistance for DC Operation Half Wave Rectifier can be measured.
Copied!