Motor Terminal Voltage in Regenerative Braking Formula

Fx Copy
LaTeX Copy
Motor Terminal Voltage refers to the voltage measured at the terminals of the electric motor while it acts as a generator, converting kinetic energy back into electrical energy. Check FAQs
Va=(1T)(Vsx,x,ton,T)
Va - Motor Terminal Voltage?T - Time Taken for Complete Operation?Vs - Source Voltage?ton - On-Period Time?

Motor Terminal Voltage in Regenerative Braking Example

With values
With units
Only example

Here is how the Motor Terminal Voltage in Regenerative Braking equation looks like with Values.

Here is how the Motor Terminal Voltage in Regenerative Braking equation looks like with Units.

Here is how the Motor Terminal Voltage in Regenerative Braking equation looks like.

385.8454Edit=(16.88Edit)(118Editx,x,1.53Edit,6.88Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Utilization of Electrical Energy » fx Motor Terminal Voltage in Regenerative Braking

Motor Terminal Voltage in Regenerative Braking Solution

Follow our step by step solution on how to calculate Motor Terminal Voltage in Regenerative Braking?

FIRST Step Consider the formula
Va=(1T)(Vsx,x,ton,T)
Next Step Substitute values of Variables
Va=(16.88s)(118Vx,x,1.53s,6.88s)
Next Step Prepare to Evaluate
Va=(16.88)(118x,x,1.53,6.88)
Next Step Evaluate
Va=385.845421511628V
LAST Step Rounding Answer
Va=385.8454V

Motor Terminal Voltage in Regenerative Braking Formula Elements

Variables
Functions
Motor Terminal Voltage
Motor Terminal Voltage refers to the voltage measured at the terminals of the electric motor while it acts as a generator, converting kinetic energy back into electrical energy.
Symbol: Va
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Time Taken for Complete Operation
Time Taken for Complete Operation represent the entire duration of operation or a significant portion of it. And it is the duration over which the integral is being calculated.
Symbol: T
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Source Voltage
Source Voltage is defined as the voltage or potential difference of the source which is supplying voltage.
Symbol: Vs
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
On-Period Time
On-Period Time refers to the duration of time during which a system is actively turned on or in an active state within a specified time frame or cycle.
Symbol: ton
Measurement: TimeUnit: s
Note: Value should be greater than 0.
int
The definite integral can be used to calculate net signed area, which is the area above the x -axis minus the area below the x -axis.
Syntax: int(expr, arg, from, to)

Other formulas in Electric Traction Drives category

​Go Torque of Squirrel Cage Induction Motor
τ=KE2Rr(Rs+Rr)2+(Xs+Xr)2
​Go DC Output Voltage of Rectifier in Scherbius Drive Given Maximum Rotor Voltage
EDC=3(Epeakπ)
​Go DC Output Voltage of Rectifier in Scherbius Drive Given Rotor RMS Line Voltage
EDC=(32)(Erπ)
​Go DC Output Voltage of Rectifier in Scherbius Drive Given Rotor RMS Line Voltage at Slip
EDC=1.35Erms

How to Evaluate Motor Terminal Voltage in Regenerative Braking?

Motor Terminal Voltage in Regenerative Braking evaluator uses Motor Terminal Voltage = (1/Time Taken for Complete Operation)*int(Source Voltage*x,x,On-Period Time,Time Taken for Complete Operation) to evaluate the Motor Terminal Voltage, The Motor Terminal Voltage in Regenerative Braking refers to the voltage measured at the terminals of the electric motor while it acts as a generator, converting kinetic energy (motion) back into electrical energy to be fed back into the power source. Motor Terminal Voltage is denoted by Va symbol.

How to evaluate Motor Terminal Voltage in Regenerative Braking using this online evaluator? To use this online evaluator for Motor Terminal Voltage in Regenerative Braking, enter Time Taken for Complete Operation (T), Source Voltage (Vs) & On-Period Time (ton) and hit the calculate button.

FAQs on Motor Terminal Voltage in Regenerative Braking

What is the formula to find Motor Terminal Voltage in Regenerative Braking?
The formula of Motor Terminal Voltage in Regenerative Braking is expressed as Motor Terminal Voltage = (1/Time Taken for Complete Operation)*int(Source Voltage*x,x,On-Period Time,Time Taken for Complete Operation). Here is an example- 385.8454 = (1/6.88)*int(118*x,x,1.53,6.88).
How to calculate Motor Terminal Voltage in Regenerative Braking?
With Time Taken for Complete Operation (T), Source Voltage (Vs) & On-Period Time (ton) we can find Motor Terminal Voltage in Regenerative Braking using the formula - Motor Terminal Voltage = (1/Time Taken for Complete Operation)*int(Source Voltage*x,x,On-Period Time,Time Taken for Complete Operation). This formula also uses Definite Integral (int) function(s).
Can the Motor Terminal Voltage in Regenerative Braking be negative?
No, the Motor Terminal Voltage in Regenerative Braking, measured in Electric Potential cannot be negative.
Which unit is used to measure Motor Terminal Voltage in Regenerative Braking?
Motor Terminal Voltage in Regenerative Braking is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Motor Terminal Voltage in Regenerative Braking can be measured.
Copied!