Molar Flow Rate of Unreacted Reactant using Reactant Conversion Formula

Fx Copy
LaTeX Copy
Molar Flow Rate of Unreacted Reactant gives the number of moles of unreacted reactant leaving the system per unit time. Check FAQs
FA=FAo(1-XA)
FA - Molar Flow Rate of Unreacted Reactant?FAo - Molar Feed Rate of Reactant?XA - Reactant Conversion?

Molar Flow Rate of Unreacted Reactant using Reactant Conversion Example

With values
With units
Only example

Here is how the Molar Flow Rate of Unreacted Reactant using Reactant Conversion equation looks like with Values.

Here is how the Molar Flow Rate of Unreacted Reactant using Reactant Conversion equation looks like with Units.

Here is how the Molar Flow Rate of Unreacted Reactant using Reactant Conversion equation looks like.

1.5Edit=5Edit(1-0.7Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Molar Flow Rate of Unreacted Reactant using Reactant Conversion

Molar Flow Rate of Unreacted Reactant using Reactant Conversion Solution

Follow our step by step solution on how to calculate Molar Flow Rate of Unreacted Reactant using Reactant Conversion?

FIRST Step Consider the formula
FA=FAo(1-XA)
Next Step Substitute values of Variables
FA=5mol/s(1-0.7)
Next Step Prepare to Evaluate
FA=5(1-0.7)
LAST Step Evaluate
FA=1.5mol/s

Molar Flow Rate of Unreacted Reactant using Reactant Conversion Formula Elements

Variables
Molar Flow Rate of Unreacted Reactant
Molar Flow Rate of Unreacted Reactant gives the number of moles of unreacted reactant leaving the system per unit time.
Symbol: FA
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Molar Feed Rate of Reactant
The Molar Feed Rate of Reactant gives the number of moles of A being fed to the reactor per unit time.
Symbol: FAo
Measurement: Molar Flow RateUnit: mol/s
Note: Value should be greater than 0.
Reactant Conversion
Reactant Conversion gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Symbol: XA
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other formulas in Basic Formulas category

​Go Instantaneous Fractional Yield
φ=dPdR
​Go Number of Moles of Product Formed
dP=dRφ
​Go Number of Moles of Reactant Reacted
dR=dPφ
​Go Overall Fractional Yield
Φ=PR0-Rf

How to Evaluate Molar Flow Rate of Unreacted Reactant using Reactant Conversion?

Molar Flow Rate of Unreacted Reactant using Reactant Conversion evaluator uses Molar Flow Rate of Unreacted Reactant = Molar Feed Rate of Reactant*(1-Reactant Conversion) to evaluate the Molar Flow Rate of Unreacted Reactant, The Molar Flow Rate of Unreacted Reactant using Reactant Conversion gives us the number of moles of A leaving the system per unit time if conversion at the outlet is known. Molar Flow Rate of Unreacted Reactant is denoted by FA symbol.

How to evaluate Molar Flow Rate of Unreacted Reactant using Reactant Conversion using this online evaluator? To use this online evaluator for Molar Flow Rate of Unreacted Reactant using Reactant Conversion, enter Molar Feed Rate of Reactant (FAo) & Reactant Conversion (XA) and hit the calculate button.

FAQs on Molar Flow Rate of Unreacted Reactant using Reactant Conversion

What is the formula to find Molar Flow Rate of Unreacted Reactant using Reactant Conversion?
The formula of Molar Flow Rate of Unreacted Reactant using Reactant Conversion is expressed as Molar Flow Rate of Unreacted Reactant = Molar Feed Rate of Reactant*(1-Reactant Conversion). Here is an example- 1.5 = 5*(1-0.7).
How to calculate Molar Flow Rate of Unreacted Reactant using Reactant Conversion?
With Molar Feed Rate of Reactant (FAo) & Reactant Conversion (XA) we can find Molar Flow Rate of Unreacted Reactant using Reactant Conversion using the formula - Molar Flow Rate of Unreacted Reactant = Molar Feed Rate of Reactant*(1-Reactant Conversion).
Can the Molar Flow Rate of Unreacted Reactant using Reactant Conversion be negative?
No, the Molar Flow Rate of Unreacted Reactant using Reactant Conversion, measured in Molar Flow Rate cannot be negative.
Which unit is used to measure Molar Flow Rate of Unreacted Reactant using Reactant Conversion?
Molar Flow Rate of Unreacted Reactant using Reactant Conversion is usually measured using the Mole per Second[mol/s] for Molar Flow Rate. Kilomole per Second[mol/s], Dekamole per Second[mol/s], Mole per Minute[mol/s] are the few other units in which Molar Flow Rate of Unreacted Reactant using Reactant Conversion can be measured.
Copied!