The Transmissivity refers to the measure of how much water can be transmitted horizontally through an aquifer is the product of the hydraulic conductivity of the aquifer and its saturated thickness. Check FAQs
τ=35qΔs
τ - Transmissivity?q - Pumping Rate?Δs - Drawdown Across One Log Cycle?

Modified equation for transmissivity from time drawdown graphs Example

With values
With units
Only example

Here is how the Modified equation for transmissivity from time drawdown graphs equation looks like with Values.

Here is how the Modified equation for transmissivity from time drawdown graphs equation looks like with Units.

Here is how the Modified equation for transmissivity from time drawdown graphs equation looks like.

5.4994Edit=357Edit44.55Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Modified equation for transmissivity from time drawdown graphs

Modified equation for transmissivity from time drawdown graphs Solution

Follow our step by step solution on how to calculate Modified equation for transmissivity from time drawdown graphs?

FIRST Step Consider the formula
τ=35qΔs
Next Step Substitute values of Variables
τ=357m³/s44.55
Next Step Prepare to Evaluate
τ=35744.55
Next Step Evaluate
τ=5.49943883277217m²/s
LAST Step Rounding Answer
τ=5.4994m²/s

Modified equation for transmissivity from time drawdown graphs Formula Elements

Variables
Transmissivity
The Transmissivity refers to the measure of how much water can be transmitted horizontally through an aquifer is the product of the hydraulic conductivity of the aquifer and its saturated thickness.
Symbol: τ
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Pumping Rate
The Pumping Rate is referred as volume of water (or other fluid) that is pumped per unit of time. It’s typically measured in units like liters per second (L/s) or cubic meters per hour (m³/h).
Symbol: q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Drawdown Across One Log Cycle
The Drawdown Across One Log Cycle is referred as change in water level (or hydraulic head) in an aquifer due to pumping from a well.
Symbol: Δs
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Transmissivity

​Go Transmissivity derived from time drawdown graphs
τ=2.3q4πΔs

Other formulas in Time Drawdown Analysis category

​Go Time at which Steady Shape Conditions Develop
tc=7200r2Sτ
​Go Storage Coefficient given time at which Steady Shape conditions develops
S=τtc7200r2
​Go Equation for pumping rate of transmissivity from time drawdown graphs
q=τ4πΔsD2.3
​Go Equation for drawdown across one log cycle
ΔsD=2.3qτ4π

How to Evaluate Modified equation for transmissivity from time drawdown graphs?

Modified equation for transmissivity from time drawdown graphs evaluator uses Transmissivity = 35*Pumping Rate/Drawdown Across One Log Cycle to evaluate the Transmissivity, The Modified equation for transmissivity from time drawdown graphs is the rate at which groundwater can flow through an aquifer section of unit width under a unit hydraulic gradient. Transmissivity is denoted by τ symbol.

How to evaluate Modified equation for transmissivity from time drawdown graphs using this online evaluator? To use this online evaluator for Modified equation for transmissivity from time drawdown graphs, enter Pumping Rate (q) & Drawdown Across One Log Cycle (Δs) and hit the calculate button.

FAQs on Modified equation for transmissivity from time drawdown graphs

What is the formula to find Modified equation for transmissivity from time drawdown graphs?
The formula of Modified equation for transmissivity from time drawdown graphs is expressed as Transmissivity = 35*Pumping Rate/Drawdown Across One Log Cycle. Here is an example- 5.499439 = 35*7/44.55.
How to calculate Modified equation for transmissivity from time drawdown graphs?
With Pumping Rate (q) & Drawdown Across One Log Cycle (Δs) we can find Modified equation for transmissivity from time drawdown graphs using the formula - Transmissivity = 35*Pumping Rate/Drawdown Across One Log Cycle.
What are the other ways to Calculate Transmissivity?
Here are the different ways to Calculate Transmissivity-
  • Transmissivity=(2.3*Pumping Rate)/(4*pi*Drawdown Across One Log Cycle)OpenImg
Can the Modified equation for transmissivity from time drawdown graphs be negative?
No, the Modified equation for transmissivity from time drawdown graphs, measured in Kinematic Viscosity cannot be negative.
Which unit is used to measure Modified equation for transmissivity from time drawdown graphs?
Modified equation for transmissivity from time drawdown graphs is usually measured using the Square Meter per Second[m²/s] for Kinematic Viscosity. Square Meter per Hour[m²/s], Square Centimeter per Second[m²/s], Square Millimeter per Second[m²/s] are the few other units in which Modified equation for transmissivity from time drawdown graphs can be measured.
Copied!