Mixed Liquor Suspended Solids refers to the concentration of suspended solids in the mixed liquor of an aeration tank during the activated sludge process. Check FAQs
X'=θcQXrV
X' - Mixed Liquor Suspended Solids?θc - Mean Cell Residence Time?Q - WAS Pumping Rate from Return Line mlss?Xr - Sludge Concentration in Return Line?V - Reactor Volume?

MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Example

With values
With units
Only example

Here is how the MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like with Values.

Here is how the MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like with Units.

Here is how the MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low equation looks like.

420Edit=7Edit300Edit200Edit1000Edit
You are here -

MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Solution

Follow our step by step solution on how to calculate MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?

FIRST Step Consider the formula
X'=θcQXrV
Next Step Substitute values of Variables
X'=7d300m³/d200mg/L1000
Next Step Convert Units
X'=604800s0.0035m³/s0.2kg/m³1000
Next Step Prepare to Evaluate
X'=6048000.00350.21000
Next Step Evaluate
X'=0.42kg/m³
LAST Step Convert to Output's Unit
X'=420mg/L

MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low Formula Elements

Variables
Mixed Liquor Suspended Solids
Mixed Liquor Suspended Solids refers to the concentration of suspended solids in the mixed liquor of an aeration tank during the activated sludge process.
Symbol: X'
Measurement: DensityUnit: mg/L
Note: Value should be less than 6500.
Mean Cell Residence Time
Mean Cell Residence Time is the average time that the sludge remains in the reactor.
Symbol: θc
Measurement: TimeUnit: d
Note: Value should be between 5 to 15.
WAS Pumping Rate from Return Line mlss
WAS Pumping Rate from Return Line mlss is the flow rate of waste sludge from the return line.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/d
Note: Value should be greater than 0.
Sludge Concentration in Return Line
Sludge Concentration in Return Line refers to the concentration of suspended solids in the sludge that is being pumped back from the secondary clarifier to the aeration tank.
Symbol: Xr
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Reactor Volume
Reactor Volume refers to the physical volume of a reactor used in chemical processes.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.

Other Formulas to find Mixed Liquor Suspended Solids

​Go Mixed Liquor Suspended Solids given Wasting Rate from Return Line
X'=θc(QXr)+(QeXe)V
​Go MLSS given RAS Pumping Rate from Aeration Tank
X'=XrQr+QQa+Qr

Other formulas in MLSS and MLVSS category

​Go Mixed Liquor Volatile Suspended Solids given Reactor Volume
Xa'=θcQaY(Xa-S)V(1+(kdθc))

How to Evaluate MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?

MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low evaluator uses Mixed Liquor Suspended Solids = Mean Cell Residence Time*WAS Pumping Rate from Return Line mlss*Sludge Concentration in Return Line/Reactor Volume to evaluate the Mixed Liquor Suspended Solids, The MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low formula is defined as a measure of the concentration of suspended solids in the mixed liquor of an aeration tank, typically part of an activated sludge process in wastewater treatment. MLSS is crucial because it indicates the amount of biomass (microorganisms) available to break down organic matter in the wastewater. Mixed Liquor Suspended Solids is denoted by X' symbol.

How to evaluate MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low using this online evaluator? To use this online evaluator for MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low, enter Mean Cell Residence Time c), WAS Pumping Rate from Return Line mlss (Q), Sludge Concentration in Return Line (Xr) & Reactor Volume (V) and hit the calculate button.

FAQs on MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low

What is the formula to find MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
The formula of MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low is expressed as Mixed Liquor Suspended Solids = Mean Cell Residence Time*WAS Pumping Rate from Return Line mlss*Sludge Concentration in Return Line/Reactor Volume. Here is an example- 420000 = 604800*0.00347222222222222*0.2/1000.
How to calculate MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
With Mean Cell Residence Time c), WAS Pumping Rate from Return Line mlss (Q), Sludge Concentration in Return Line (Xr) & Reactor Volume (V) we can find MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low using the formula - Mixed Liquor Suspended Solids = Mean Cell Residence Time*WAS Pumping Rate from Return Line mlss*Sludge Concentration in Return Line/Reactor Volume.
What are the other ways to Calculate Mixed Liquor Suspended Solids?
Here are the different ways to Calculate Mixed Liquor Suspended Solids-
  • Mixed Liquor Suspended Solids=Mean Cell Residence Time*((WAS Pumping Rate from Return Line mlss*Sludge Concentration in Return Line)+(Effluent Flow Rate*Solid Concentration in Effluent))/Reactor VolumeOpenImg
  • Mixed Liquor Suspended Solids=Sludge Concentration in Return Line*(Return Activated Sludge MLSS MLVSS+WAS Pumping Rate from Return Line mlss)/(Average Daily Influent Flow Rate+Return Activated Sludge MLSS MLVSS)OpenImg
Can the MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low be negative?
No, the MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low, measured in Density cannot be negative.
Which unit is used to measure MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low?
MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which MLSS using Wasting Rate from Return Line when Concentration of Solid in Effluent is Low can be measured.
Copied!