Minimum Web Thickness for Symmetrical Flexural Compact Section for LFD of Bridges evaluator uses Web Minimum Thickness = Depth of Section*sqrt(Yield Strength of Steel)/608 to evaluate the Web Minimum Thickness, The Minimum Web Thickness for Symmetrical Flexural Compact Section for LFD of Bridges formula is defined as smallest thickness of web plate used in design. Web Minimum Thickness is denoted by tu symbol.
How to evaluate Minimum Web Thickness for Symmetrical Flexural Compact Section for LFD of Bridges using this online evaluator? To use this online evaluator for Minimum Web Thickness for Symmetrical Flexural Compact Section for LFD of Bridges, enter Depth of Section (d) & Yield Strength of Steel (fy) and hit the calculate button.