Fx Copy
LaTeX Copy
The common-mode range is for signal processing devices with differential inputs, such as an op-amp. Check FAQs
Vcmr=Vt+Vov+Vgs-VL
Vcmr - Common-Mode Range?Vt - Threshold Voltage?Vov - Effective Voltage?Vgs - Voltage between Gate and Source?VL - Load Voltage?

Minimum Input Common-Mode Range of MOS Differential Amplifier Example

With values
With units
Only example

Here is how the Minimum Input Common-Mode Range of MOS Differential Amplifier equation looks like with Values.

Here is how the Minimum Input Common-Mode Range of MOS Differential Amplifier equation looks like with Units.

Here is how the Minimum Input Common-Mode Range of MOS Differential Amplifier equation looks like.

3.36Edit=19.5Edit+2.5Edit+4Edit-22.64Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Amplifiers » fx Minimum Input Common-Mode Range of MOS Differential Amplifier

Minimum Input Common-Mode Range of MOS Differential Amplifier Solution

Follow our step by step solution on how to calculate Minimum Input Common-Mode Range of MOS Differential Amplifier?

FIRST Step Consider the formula
Vcmr=Vt+Vov+Vgs-VL
Next Step Substitute values of Variables
Vcmr=19.5V+2.5V+4V-22.64V
Next Step Prepare to Evaluate
Vcmr=19.5+2.5+4-22.64
LAST Step Evaluate
Vcmr=3.36V

Minimum Input Common-Mode Range of MOS Differential Amplifier Formula Elements

Variables
Common-Mode Range
The common-mode range is for signal processing devices with differential inputs, such as an op-amp.
Symbol: Vcmr
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Threshold Voltage
Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals.
Symbol: Vt
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Effective Voltage
Effective voltage or overdrive voltage is excess of voltage across oxide over thermal voltage is termed.
Symbol: Vov
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Voltage between Gate and Source
The voltage between gate and source is the voltage that falls across the gate-source terminal of the transistor.
Symbol: Vgs
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Load Voltage
The Load Voltage is defined as the voltage between two terminals of load.
Symbol: VL
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Common-Mode Range

​Go Maximum Input Common-Mode Range of MOS Differential Amplifier
Vcmr=Vt+VL-(12RL)

Other formulas in Differential Configuration category

​Go Input Voltage of MOS Differential Amplifier on Small-Signal Operation
Vin=Vcm+(12Vis)
​Go Input Offset Voltage of MOS Differential Amplifier
Vos=VoAd
​Go Input Offset Voltage of MOS Differential Amplifier when Aspect Ratio Mismatches
Vos=(Vov2)(WLWL1)
​Go Input Offset Voltage of MOS Differential Amplifier given Saturation Current
Vos=Vt(IscIs)

How to Evaluate Minimum Input Common-Mode Range of MOS Differential Amplifier?

Minimum Input Common-Mode Range of MOS Differential Amplifier evaluator uses Common-Mode Range = Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load Voltage to evaluate the Common-Mode Range, Minimum input common-mode range of MOS differential amplifier formula is for signal processing devices with differential inputs, such as op-amp, CMVR is range of common-mode signal for which amplifier's operation remains linear. Common-Mode Range is denoted by Vcmr symbol.

How to evaluate Minimum Input Common-Mode Range of MOS Differential Amplifier using this online evaluator? To use this online evaluator for Minimum Input Common-Mode Range of MOS Differential Amplifier, enter Threshold Voltage (Vt), Effective Voltage (Vov), Voltage between Gate and Source (Vgs) & Load Voltage (VL) and hit the calculate button.

FAQs on Minimum Input Common-Mode Range of MOS Differential Amplifier

What is the formula to find Minimum Input Common-Mode Range of MOS Differential Amplifier?
The formula of Minimum Input Common-Mode Range of MOS Differential Amplifier is expressed as Common-Mode Range = Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load Voltage. Here is an example- 3.36 = 19.5+2.5+4-22.64.
How to calculate Minimum Input Common-Mode Range of MOS Differential Amplifier?
With Threshold Voltage (Vt), Effective Voltage (Vov), Voltage between Gate and Source (Vgs) & Load Voltage (VL) we can find Minimum Input Common-Mode Range of MOS Differential Amplifier using the formula - Common-Mode Range = Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load Voltage.
What are the other ways to Calculate Common-Mode Range?
Here are the different ways to Calculate Common-Mode Range-
  • Common-Mode Range=Threshold Voltage+Load Voltage-(1/2*Load Resistance)OpenImg
Can the Minimum Input Common-Mode Range of MOS Differential Amplifier be negative?
No, the Minimum Input Common-Mode Range of MOS Differential Amplifier, measured in Electric Potential cannot be negative.
Which unit is used to measure Minimum Input Common-Mode Range of MOS Differential Amplifier?
Minimum Input Common-Mode Range of MOS Differential Amplifier is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Minimum Input Common-Mode Range of MOS Differential Amplifier can be measured.
Copied!