Fx Copy
LaTeX Copy
The Head Loss is a measure of the reduction in the total head (sum of elevation head, velocity head and pressure head) of the fluid as it moves through a fluid system. Check FAQs
hL=0.0729(v2-u2)
hL - Head Loss?v - Velocity of Flow after Screening?u - Velocity of Flow before Screening?

Minimum Head Loss when screen is fully functional Example

With values
With units
Only example

Here is how the Minimum Head Loss when screen is fully functional equation looks like with Values.

Here is how the Minimum Head Loss when screen is fully functional equation looks like with Units.

Here is how the Minimum Head Loss when screen is fully functional equation looks like.

2.8431Edit=0.0729(8Edit2-5Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Minimum Head Loss when screen is fully functional

Minimum Head Loss when screen is fully functional Solution

Follow our step by step solution on how to calculate Minimum Head Loss when screen is fully functional?

FIRST Step Consider the formula
hL=0.0729(v2-u2)
Next Step Substitute values of Variables
hL=0.0729(8m/s2-5m/s2)
Next Step Prepare to Evaluate
hL=0.0729(82-52)
LAST Step Evaluate
hL=2.8431m

Minimum Head Loss when screen is fully functional Formula Elements

Variables
Head Loss
The Head Loss is a measure of the reduction in the total head (sum of elevation head, velocity head and pressure head) of the fluid as it moves through a fluid system.
Symbol: hL
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Velocity of Flow after Screening
The Velocity of Flow after Screening is the flow of water after the screening which depends upon the clear spacing area within the screen.
Symbol: v
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.
Velocity of Flow before Screening
The Velocity of Flow before Screening is the flow of water before screening which depends upon the cross-section area of the channel.
Symbol: u
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.

Other Formulas to find Head Loss

​Go Head Loss through Screen
hL=0.0729(v2-u2)
​Go Maximum Head Loss when screen is 50 percent clogged
hL=0.0729((2v)2-u2)

Other formulas in Screening category

​Go Velocity through Screen given Head Loss through Screen
v=(hL0.0729)+u2
​Go Velocity above Screen given Head Loss through Screen
u=v2-(hL0.0729)

How to Evaluate Minimum Head Loss when screen is fully functional?

Minimum Head Loss when screen is fully functional evaluator uses Head Loss = 0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2) to evaluate the Head Loss, The Minimum Head Loss when screen is fully functional is defined as the Head Loss through Screen, which measures the reduction in the total head of the fluid as it moves through a fluid system. Head Loss is denoted by hL symbol.

How to evaluate Minimum Head Loss when screen is fully functional using this online evaluator? To use this online evaluator for Minimum Head Loss when screen is fully functional, enter Velocity of Flow after Screening (v) & Velocity of Flow before Screening (u) and hit the calculate button.

FAQs on Minimum Head Loss when screen is fully functional

What is the formula to find Minimum Head Loss when screen is fully functional?
The formula of Minimum Head Loss when screen is fully functional is expressed as Head Loss = 0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2). Here is an example- 2.8431 = 0.0729*(8^2-5^2).
How to calculate Minimum Head Loss when screen is fully functional?
With Velocity of Flow after Screening (v) & Velocity of Flow before Screening (u) we can find Minimum Head Loss when screen is fully functional using the formula - Head Loss = 0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2).
What are the other ways to Calculate Head Loss?
Here are the different ways to Calculate Head Loss-
  • Head Loss=0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2)OpenImg
  • Head Loss=0.0729*((2*Velocity of Flow after Screening)^2-Velocity of Flow before Screening^2)OpenImg
Can the Minimum Head Loss when screen is fully functional be negative?
Yes, the Minimum Head Loss when screen is fully functional, measured in Length can be negative.
Which unit is used to measure Minimum Head Loss when screen is fully functional?
Minimum Head Loss when screen is fully functional is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Minimum Head Loss when screen is fully functional can be measured.
Copied!