Minimum Frequency to Avoid Saturation Formula

Fx Copy
LaTeX Copy
Frequency is defined as the frequency which is needed to avoid the saturation. Check FAQs
f=Vm2πN2A
f - Frequency?Vm - Peak Voltage?N2 - Secondary Turns of Coil?A - Area of Coil?π - Archimedes' constant?

Minimum Frequency to Avoid Saturation Example

With values
With units
Only example

Here is how the Minimum Frequency to Avoid Saturation equation looks like with Values.

Here is how the Minimum Frequency to Avoid Saturation equation looks like with Units.

Here is how the Minimum Frequency to Avoid Saturation equation looks like.

15.5618Edit=440Edit23.141618Edit0.25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Electrical Circuit » fx Minimum Frequency to Avoid Saturation

Minimum Frequency to Avoid Saturation Solution

Follow our step by step solution on how to calculate Minimum Frequency to Avoid Saturation?

FIRST Step Consider the formula
f=Vm2πN2A
Next Step Substitute values of Variables
f=440V2π180.25
Next Step Substitute values of Constants
f=440V23.1416180.25
Next Step Prepare to Evaluate
f=44023.1416180.25
Next Step Evaluate
f=15.5618166578742Hz
LAST Step Rounding Answer
f=15.5618Hz

Minimum Frequency to Avoid Saturation Formula Elements

Variables
Constants
Frequency
Frequency is defined as the frequency which is needed to avoid the saturation.
Symbol: f
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.
Peak Voltage
Peak Voltage is defined a the maximum amplitude achieved by the voltage wave.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Secondary Turns of Coil
Secondary turns of coil is number of turns of 2nd winding or number of turns of secondary winding of transformer.
Symbol: N2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Area of Coil
The area of coil is the region bounded by the shape of an object. The space covered by the figure or any two-dimensional geometric shape, in a plane, is the area of the shape.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Electrical Specifications category

​Go Forces on Charges Moving in Magnetic Fields
F=quBsin(θ)
​Go Forces on Current Carrying Wires
F=Bilsin(θ)
​Go Voltages Induced in Field Cutting Conductors
e=Blu
​Go Energy Stored in Magnetic Field
E=Bμ2

How to Evaluate Minimum Frequency to Avoid Saturation?

Minimum Frequency to Avoid Saturation evaluator uses Frequency = Peak Voltage/(2*pi*Secondary Turns of Coil*Area of Coil) to evaluate the Frequency, The Minimum Frequency to avoid Saturation formula is defined as the least amount of frequency needs to avoid the saturation of magnetic field. Frequency is denoted by f symbol.

How to evaluate Minimum Frequency to Avoid Saturation using this online evaluator? To use this online evaluator for Minimum Frequency to Avoid Saturation, enter Peak Voltage (Vm), Secondary Turns of Coil (N2) & Area of Coil (A) and hit the calculate button.

FAQs on Minimum Frequency to Avoid Saturation

What is the formula to find Minimum Frequency to Avoid Saturation?
The formula of Minimum Frequency to Avoid Saturation is expressed as Frequency = Peak Voltage/(2*pi*Secondary Turns of Coil*Area of Coil). Here is an example- 15.56182 = 440/(2*pi*18*0.25).
How to calculate Minimum Frequency to Avoid Saturation?
With Peak Voltage (Vm), Secondary Turns of Coil (N2) & Area of Coil (A) we can find Minimum Frequency to Avoid Saturation using the formula - Frequency = Peak Voltage/(2*pi*Secondary Turns of Coil*Area of Coil). This formula also uses Archimedes' constant .
Can the Minimum Frequency to Avoid Saturation be negative?
No, the Minimum Frequency to Avoid Saturation, measured in Frequency cannot be negative.
Which unit is used to measure Minimum Frequency to Avoid Saturation?
Minimum Frequency to Avoid Saturation is usually measured using the Hertz[Hz] for Frequency. Petahertz[Hz], Terahertz[Hz], Gigahertz[Hz] are the few other units in which Minimum Frequency to Avoid Saturation can be measured.
Copied!