Fx Copy
LaTeX Copy
Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes. Check FAQs
Mt=BODQQiVX
Mt - Total Microbial Mass?BOD - Daily BOD?Q - Sewage Flow?Qi - Influent BOD?V - Volume of Tank?X - MLSS?

Microbial Mass in Aeration System given MLSS Example

With values
With units
Only example

Here is how the Microbial Mass in Aeration System given MLSS equation looks like with Values.

Here is how the Microbial Mass in Aeration System given MLSS equation looks like with Units.

Here is how the Microbial Mass in Aeration System given MLSS equation looks like.

3.003Edit=3Edit3.33Edit0.0009Edit1.5Edit2Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Microbial Mass in Aeration System given MLSS

Microbial Mass in Aeration System given MLSS Solution

Follow our step by step solution on how to calculate Microbial Mass in Aeration System given MLSS?

FIRST Step Consider the formula
Mt=BODQQiVX
Next Step Substitute values of Variables
Mt=3mg3.330.0009mg/L1.52mg/L
Next Step Convert Units
Mt=3E-6kg3.339E-7kg/m³1.50.002kg/m³
Next Step Prepare to Evaluate
Mt=3E-63.339E-71.50.002
Next Step Evaluate
Mt=0.003003003003003kg
Next Step Convert to Output's Unit
Mt=3.003003003003g
LAST Step Rounding Answer
Mt=3.003g

Microbial Mass in Aeration System given MLSS Formula Elements

Variables
Total Microbial Mass
Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes.
Symbol: Mt
Measurement: WeightUnit: g
Note: Value should be greater than 0.
Daily BOD
Daily BOD load measures the amount of oxygen that microorganisms will consume while decomposing organic matter in a water sample over a 24-hour period.
Symbol: BOD
Measurement: WeightUnit: mg
Note: Value should be greater than 0.
Sewage Flow
Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
Symbol: Q
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
MLSS
MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
Symbol: X
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other Formulas to find Total Microbial Mass

​Go Total Microbial Mass given Food to Microorganism Ratio
Mt=BODFM

Other formulas in Food is to Microorganism Ratio or F is to M Ratio category

​Go Food to Microorganism Ratio
FM=BODMt
​Go Daily BOD Load given Food to Microorganism Ratio
BOD=FMMt
​Go BOD Load applied to Aeration System
BODa=QQi
​Go Sewage Flow into Aeration System given BOD Load Applied
Q=BODQi

How to Evaluate Microbial Mass in Aeration System given MLSS?

Microbial Mass in Aeration System given MLSS evaluator uses Total Microbial Mass = Daily BOD/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS)) to evaluate the Total Microbial Mass, The Microbial Mass in Aeration System given MLSS formula is defined as the concentration of microorganisms, primarily bacteria, present within the aeration tank of a wastewater treatment plant, considering MLSS. Total Microbial Mass is denoted by Mt symbol.

How to evaluate Microbial Mass in Aeration System given MLSS using this online evaluator? To use this online evaluator for Microbial Mass in Aeration System given MLSS, enter Daily BOD (BOD), Sewage Flow (Q), Influent BOD (Qi), Volume of Tank (V) & MLSS (X) and hit the calculate button.

FAQs on Microbial Mass in Aeration System given MLSS

What is the formula to find Microbial Mass in Aeration System given MLSS?
The formula of Microbial Mass in Aeration System given MLSS is expressed as Total Microbial Mass = Daily BOD/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS)). Here is an example- 18018.02 = 3E-06/((3.33*9E-07)/(1.5*0.002)).
How to calculate Microbial Mass in Aeration System given MLSS?
With Daily BOD (BOD), Sewage Flow (Q), Influent BOD (Qi), Volume of Tank (V) & MLSS (X) we can find Microbial Mass in Aeration System given MLSS using the formula - Total Microbial Mass = Daily BOD/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS)).
What are the other ways to Calculate Total Microbial Mass?
Here are the different ways to Calculate Total Microbial Mass-
  • Total Microbial Mass=Daily BOD/Food to Microorganism RatioOpenImg
Can the Microbial Mass in Aeration System given MLSS be negative?
No, the Microbial Mass in Aeration System given MLSS, measured in Weight cannot be negative.
Which unit is used to measure Microbial Mass in Aeration System given MLSS?
Microbial Mass in Aeration System given MLSS is usually measured using the Gram[g] for Weight. Kilogram[g], Milligram[g], Ton (Metric)[g] are the few other units in which Microbial Mass in Aeration System given MLSS can be measured.
Copied!