Fx Copy
LaTeX Copy
Flux through membrane is defined as the rate of movement or transfer of a substance per unit area across a porous barrier known as a membrane. Check FAQs
JwM=LpPA
JwM - Flux through Membrane?Lp - Water Permeability Through Membrane?PA - Applied Pressure?

Membrane Flux Based on Water Permeability Example

With values
With units
Only example

Here is how the Membrane Flux Based on Water Permeability equation looks like with Values.

Here is how the Membrane Flux Based on Water Permeability equation looks like with Units.

Here is how the Membrane Flux Based on Water Permeability equation looks like.

2.1E-7Edit=2.3E-8Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Membrane Flux Based on Water Permeability

Membrane Flux Based on Water Permeability Solution

Follow our step by step solution on how to calculate Membrane Flux Based on Water Permeability?

FIRST Step Consider the formula
JwM=LpPA
Next Step Substitute values of Variables
JwM=2.3E-8m³/(m²*s*Pa)9Pa
Next Step Prepare to Evaluate
JwM=2.3E-89
Next Step Evaluate
JwM=2.1033E-07m³/(m²*s)
LAST Step Rounding Answer
JwM=2.1E-7m³/(m²*s)

Membrane Flux Based on Water Permeability Formula Elements

Variables
Flux through Membrane
Flux through membrane is defined as the rate of movement or transfer of a substance per unit area across a porous barrier known as a membrane.
Symbol: JwM
Measurement: Membrane FluxUnit: m³/(m²*s)
Note: Value should be greater than 0.
Water Permeability Through Membrane
Water permeability through membrane is the ability of a material to allow water to pass through it. It is a measure of how easily water can flow through a material's pores.
Symbol: Lp
Measurement: Water PermeabilityUnit: m³/(m²*s*Pa)
Note: Value should be greater than 0.
Applied Pressure
Applied Pressure is the pressure that is applied on the object of interest.
Symbol: PA
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.

Other Formulas to find Flux through Membrane

​Go Hagen Poiseuille Based Flux for Membrane Separation
JwM=εd2ΔPm32μΤlmt
​Go Membrane Flux Based on Resistance
JwM=ΔPmRmμ

Other formulas in Basics of Membrane Separation Processes category

​Go Resistance to flow in Membranes
Rm=ΔPmμJwM
​Go Liquid Viscosity based on Membrane Resistance
μ=ΔPmRmJwM
​Go Water Permeability through Membrane
Lp=JwMΔPm
​Go Tortuosity Factor of Pores
Τ=εd2ΔPm32μJwMlmt

How to Evaluate Membrane Flux Based on Water Permeability?

Membrane Flux Based on Water Permeability evaluator uses Flux through Membrane = Water Permeability Through Membrane*Applied Pressure to evaluate the Flux through Membrane, Membrane Flux Based on Water Permeability refers to the rate at which water molecules pass through a semipermeable membrane, driven by the membrane's intrinsic capacity to facilitate water transport and the presence of a driving force. Flux through Membrane is denoted by JwM symbol.

How to evaluate Membrane Flux Based on Water Permeability using this online evaluator? To use this online evaluator for Membrane Flux Based on Water Permeability, enter Water Permeability Through Membrane (Lp) & Applied Pressure (PA) and hit the calculate button.

FAQs on Membrane Flux Based on Water Permeability

What is the formula to find Membrane Flux Based on Water Permeability?
The formula of Membrane Flux Based on Water Permeability is expressed as Flux through Membrane = Water Permeability Through Membrane*Applied Pressure. Here is an example- 2.1E-7 = 2.337E-08*9.
How to calculate Membrane Flux Based on Water Permeability?
With Water Permeability Through Membrane (Lp) & Applied Pressure (PA) we can find Membrane Flux Based on Water Permeability using the formula - Flux through Membrane = Water Permeability Through Membrane*Applied Pressure.
What are the other ways to Calculate Flux through Membrane?
Here are the different ways to Calculate Flux through Membrane-
  • Flux through Membrane=(Membrane Porosity*Pore Diameter^2*Applied Pressure Driving Force)/(32*Liquid Viscosity*Tortuosity*Membrane Thickness)OpenImg
  • Flux through Membrane=Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity)OpenImg
Can the Membrane Flux Based on Water Permeability be negative?
Yes, the Membrane Flux Based on Water Permeability, measured in Membrane Flux can be negative.
Which unit is used to measure Membrane Flux Based on Water Permeability?
Membrane Flux Based on Water Permeability is usually measured using the Cubic Meter per Square Meter per Second[m³/(m²*s)] for Membrane Flux. are the few other units in which Membrane Flux Based on Water Permeability can be measured.
Copied!