Fx Copy
LaTeX Copy
Flux through membrane is defined as the rate of movement or transfer of a substance per unit area across a porous barrier known as a membrane. Check FAQs
JwM=ΔPmRmμ
JwM - Flux through Membrane?ΔPm - Applied Pressure Driving Force?Rm - Membrane Flow Resistance of Unit Area?μ - Liquid Viscosity?

Membrane Flux Based on Resistance Example

With values
With units
Only example

Here is how the Membrane Flux Based on Resistance equation looks like with Values.

Here is how the Membrane Flux Based on Resistance equation looks like with Units.

Here is how the Membrane Flux Based on Resistance equation looks like.

0.0069Edit=300000Edit4.8E+10Edit0.0009Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Membrane Flux Based on Resistance

Membrane Flux Based on Resistance Solution

Follow our step by step solution on how to calculate Membrane Flux Based on Resistance?

FIRST Step Consider the formula
JwM=ΔPmRmμ
Next Step Substitute values of Variables
JwM=300000Pa4.8E+10m⁻¹0.0009Kg/ms
Next Step Convert Units
JwM=300000Pa4.8E+10m⁻¹0.0009Pa*s
Next Step Prepare to Evaluate
JwM=3000004.8E+100.0009
Next Step Evaluate
JwM=0.00694399999951114m³/(m²*s)
LAST Step Rounding Answer
JwM=0.0069m³/(m²*s)

Membrane Flux Based on Resistance Formula Elements

Variables
Flux through Membrane
Flux through membrane is defined as the rate of movement or transfer of a substance per unit area across a porous barrier known as a membrane.
Symbol: JwM
Measurement: Membrane FluxUnit: m³/(m²*s)
Note: Value should be greater than 0.
Applied Pressure Driving Force
Applied Pressure Driving Force is defined as the force or pressure that is intentionally exerted or applied to induce or facilitate process.
Symbol: ΔPm
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Membrane Flow Resistance of Unit Area
Membrane flow resistance of unit area is defined as the measure of the resistance that a membrane presents to the flow of a substance through it, normalized by the area of the membrane.
Symbol: Rm
Measurement: Reciprocal LengthUnit: m⁻¹
Note: Value should be greater than 0.
Liquid Viscosity
Liquid viscosity is defined as the measure of a fluid's resistance to flow or its internal friction when subjected to an external force.
Symbol: μ
Measurement: Dynamic ViscosityUnit: Kg/ms
Note: Value should be greater than 0.

Other Formulas to find Flux through Membrane

​Go Hagen Poiseuille Based Flux for Membrane Separation
JwM=εd2ΔPm32μΤlmt
​Go Membrane Flux Based on Water Permeability
JwM=LpPA

Other formulas in Basics of Membrane Separation Processes category

​Go Resistance to flow in Membranes
Rm=ΔPmμJwM
​Go Liquid Viscosity based on Membrane Resistance
μ=ΔPmRmJwM
​Go Water Permeability through Membrane
Lp=JwMΔPm
​Go Tortuosity Factor of Pores
Τ=εd2ΔPm32μJwMlmt

How to Evaluate Membrane Flux Based on Resistance?

Membrane Flux Based on Resistance evaluator uses Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity) to evaluate the Flux through Membrane, The Membrane Flux Based on Resistance formula is defined as is the rate of substance flow through a membrane, determined by the resistance the substance encounters while crossing the membrane. Flux through Membrane is denoted by JwM symbol.

How to evaluate Membrane Flux Based on Resistance using this online evaluator? To use this online evaluator for Membrane Flux Based on Resistance, enter Applied Pressure Driving Force (ΔPm), Membrane Flow Resistance of Unit Area (Rm) & Liquid Viscosity (μ) and hit the calculate button.

FAQs on Membrane Flux Based on Resistance

What is the formula to find Membrane Flux Based on Resistance?
The formula of Membrane Flux Based on Resistance is expressed as Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity). Here is an example- 0.017361 = 300000/(48003072200*0.0009).
How to calculate Membrane Flux Based on Resistance?
With Applied Pressure Driving Force (ΔPm), Membrane Flow Resistance of Unit Area (Rm) & Liquid Viscosity (μ) we can find Membrane Flux Based on Resistance using the formula - Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity).
What are the other ways to Calculate Flux through Membrane?
Here are the different ways to Calculate Flux through Membrane-
  • Flux through Membrane=(Membrane Porosity*Pore Diameter^2*Applied Pressure Driving Force)/(32*Liquid Viscosity*Tortuosity*Membrane Thickness)OpenImg
  • Flux through Membrane=Water Permeability Through Membrane*Applied PressureOpenImg
Can the Membrane Flux Based on Resistance be negative?
Yes, the Membrane Flux Based on Resistance, measured in Membrane Flux can be negative.
Which unit is used to measure Membrane Flux Based on Resistance?
Membrane Flux Based on Resistance is usually measured using the Cubic Meter per Square Meter per Second[m³/(m²*s)] for Membrane Flux. are the few other units in which Membrane Flux Based on Resistance can be measured.
Copied!