Mechanical Efficiency the ratio of the power delivered by a mechanical system to the power supplied to it. Check FAQs
ηm=VaIaωsτ
ηm - Mechanical Efficiency?Va - Armature Voltage?Ia - Armature Current?ωs - Angular Speed?τ - Torque?

Mechanical Efficiency of DC Generator using Armature Voltage Example

With values
With units
Only example

Here is how the Mechanical Efficiency of DC Generator using Armature Voltage equation looks like with Values.

Here is how the Mechanical Efficiency of DC Generator using Armature Voltage equation looks like with Units.

Here is how the Mechanical Efficiency of DC Generator using Armature Voltage equation looks like.

0.6824Edit=200Edit0.75Edit314Edit0.7Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Mechanical Efficiency of DC Generator using Armature Voltage

Mechanical Efficiency of DC Generator using Armature Voltage Solution

Follow our step by step solution on how to calculate Mechanical Efficiency of DC Generator using Armature Voltage?

FIRST Step Consider the formula
ηm=VaIaωsτ
Next Step Substitute values of Variables
ηm=200V0.75A314rad/s0.7N*m
Next Step Prepare to Evaluate
ηm=2000.753140.7
Next Step Evaluate
ηm=0.682438580527753
LAST Step Rounding Answer
ηm=0.6824

Mechanical Efficiency of DC Generator using Armature Voltage Formula Elements

Variables
Mechanical Efficiency
Mechanical Efficiency the ratio of the power delivered by a mechanical system to the power supplied to it.
Symbol: ηm
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Armature Voltage
Armature Voltage is defined as voltage developed at the terminals of the armature winding of an AC or DC machine during the generation of power.
Symbol: Va
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Armature Current
Armature Current is defined as the current developed in the armature of an electrical DC generator due to movement of rotor.
Symbol: Ia
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Angular Speed
Angular speed is the rate of rotation about an axis, measuring how the angle changes with time. It is measured in radian/sec.
Symbol: ωs
Measurement: Angular VelocityUnit: rad/s
Note: Value should be greater than 0.
Torque
Torque is the measure of the turning force produced by the armature. It is produced by the interaction between the magnetic field of the stator and the current flowing through armature.
Symbol: τ
Measurement: TorqueUnit: N*m
Note: Value should be greater than 0.

Other Formulas to find Mechanical Efficiency

​Go Mechanical Efficiency of DC Generator using Converted Power
ηm=PconvPin

Other formulas in DC Generator Characteristics category

​Go Converted Power in DC Generator
Pconv=VoIL
​Go Field Copper Loss in DC Generator
Pcu=If2Rf
​Go Output Voltage in DC Generator using Converted Power
Vo=PconvIL
​Go Back EMF of DC Generator given Flux
E=KeωsΦp

How to Evaluate Mechanical Efficiency of DC Generator using Armature Voltage?

Mechanical Efficiency of DC Generator using Armature Voltage evaluator uses Mechanical Efficiency = (Armature Voltage*Armature Current)/(Angular Speed*Torque) to evaluate the Mechanical Efficiency, Mechanical Efficiency of DC Generator using Armature Voltage is dependent on the power in the armature and mechanical power applied at the input. Mechanical Efficiency is denoted by ηm symbol.

How to evaluate Mechanical Efficiency of DC Generator using Armature Voltage using this online evaluator? To use this online evaluator for Mechanical Efficiency of DC Generator using Armature Voltage, enter Armature Voltage (Va), Armature Current (Ia), Angular Speed s) & Torque (τ) and hit the calculate button.

FAQs on Mechanical Efficiency of DC Generator using Armature Voltage

What is the formula to find Mechanical Efficiency of DC Generator using Armature Voltage?
The formula of Mechanical Efficiency of DC Generator using Armature Voltage is expressed as Mechanical Efficiency = (Armature Voltage*Armature Current)/(Angular Speed*Torque). Here is an example- 0.682439 = (200*0.75)/(314*0.7).
How to calculate Mechanical Efficiency of DC Generator using Armature Voltage?
With Armature Voltage (Va), Armature Current (Ia), Angular Speed s) & Torque (τ) we can find Mechanical Efficiency of DC Generator using Armature Voltage using the formula - Mechanical Efficiency = (Armature Voltage*Armature Current)/(Angular Speed*Torque).
What are the other ways to Calculate Mechanical Efficiency?
Here are the different ways to Calculate Mechanical Efficiency-
  • Mechanical Efficiency=Converted Power/Input PowerOpenImg