Discharge in Stream is the volumetric flow rate of water that is transported through a given cross-sectional area. Check FAQs
Qs=k((EdI)+K2)nsystem
Qs - Discharge in Stream?k - System Constant k?E - Signal Output?d - Depth of Flow?I - Current in Coil?K2 - System Constant K2?nsystem - System Constant n?

Measurement for Discharge in Electromagnetic Method Example

With values
With units
Only example

Here is how the Measurement for Discharge in Electromagnetic Method equation looks like with Values.

Here is how the Measurement for Discharge in Electromagnetic Method equation looks like with Units.

Here is how the Measurement for Discharge in Electromagnetic Method equation looks like.

60.0017Edit=2Edit((10Edit3.23Edit50.11Edit)+3Edit)2.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Measurement for Discharge in Electromagnetic Method

Measurement for Discharge in Electromagnetic Method Solution

Follow our step by step solution on how to calculate Measurement for Discharge in Electromagnetic Method?

FIRST Step Consider the formula
Qs=k((EdI)+K2)nsystem
Next Step Substitute values of Variables
Qs=2((103.23m50.11A)+3)2.63
Next Step Prepare to Evaluate
Qs=2((103.2350.11)+3)2.63
Next Step Evaluate
Qs=60.0016909509575m³/s
LAST Step Rounding Answer
Qs=60.0017m³/s

Measurement for Discharge in Electromagnetic Method Formula Elements

Variables
Discharge in Stream
Discharge in Stream is the volumetric flow rate of water that is transported through a given cross-sectional area.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
System Constant k
System Constant k for measuring the discharge rates in flow-measuring structures.
Symbol: k
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Signal Output
Signal Output will be of the order of millivolts and is related to discharge.
Symbol: E
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Depth of Flow
Depth of Flow is the distance from the top or surface of the flow to the bottom of a channel or other waterway or Depth of Flow at the Vertical while measuring Sound Weights.
Symbol: d
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Current in Coil
Current in Coil in the Electro-Magnetic Method of Stream Flow Measurement.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
System Constant K2
System Constant K2 in the Electro-Magnetic Method of Stream Flow Measurement.
Symbol: K2
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
System Constant n
System Constant n in the discharge rate of streamflow measurement.
Symbol: nsystem
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Electromagnetic Method category

​Go Depth of Flow in Electromagnetic Method
d=((Qsk)1nsystem-K2)IE
​Go Current in Coil in Electromagnetic Method
I=Ed(Qsk)1nsystem-K2

How to Evaluate Measurement for Discharge in Electromagnetic Method?

Measurement for Discharge in Electromagnetic Method evaluator uses Discharge in Stream = System Constant k*((Signal Output*Depth of Flow/Current in Coil)+System Constant K2)^(System Constant n) to evaluate the Discharge in Stream, The Measurement for Discharge in Electromagnetic Method formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area based on the Electro-Magnetic Method of Faraday's principle. Discharge in Stream is denoted by Qs symbol.

How to evaluate Measurement for Discharge in Electromagnetic Method using this online evaluator? To use this online evaluator for Measurement for Discharge in Electromagnetic Method, enter System Constant k (k), Signal Output (E), Depth of Flow (d), Current in Coil (I), System Constant K2 (K2) & System Constant n (nsystem) and hit the calculate button.

FAQs on Measurement for Discharge in Electromagnetic Method

What is the formula to find Measurement for Discharge in Electromagnetic Method?
The formula of Measurement for Discharge in Electromagnetic Method is expressed as Discharge in Stream = System Constant k*((Signal Output*Depth of Flow/Current in Coil)+System Constant K2)^(System Constant n). Here is an example- 60.06311 = 2*((10*3.23/50.11)+3)^(2.63).
How to calculate Measurement for Discharge in Electromagnetic Method?
With System Constant k (k), Signal Output (E), Depth of Flow (d), Current in Coil (I), System Constant K2 (K2) & System Constant n (nsystem) we can find Measurement for Discharge in Electromagnetic Method using the formula - Discharge in Stream = System Constant k*((Signal Output*Depth of Flow/Current in Coil)+System Constant K2)^(System Constant n).
Can the Measurement for Discharge in Electromagnetic Method be negative?
No, the Measurement for Discharge in Electromagnetic Method, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Measurement for Discharge in Electromagnetic Method?
Measurement for Discharge in Electromagnetic Method is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Measurement for Discharge in Electromagnetic Method can be measured.
Copied!