Measured Position at Nth Scan Formula

Fx Copy
LaTeX Copy
Measured position at Nth scan is the measured or actual position of target at the nth scan by the track-while-scan surveillance radar. Check FAQs
xn=(Xin-xpnα)+xpn
xn - Measured Position at Nth Scan?Xin - Smoothed Position?xpn - Target Predicted Position?α - Position Smoothing Parameter?

Measured Position at Nth Scan Example

With values
With units
Only example

Here is how the Measured Position at Nth Scan equation looks like with Values.

Here is how the Measured Position at Nth Scan equation looks like with Units.

Here is how the Measured Position at Nth Scan equation looks like.

6Edit=(40Edit-74Edit0.5Edit)+74Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Radar System » fx Measured Position at Nth Scan

Measured Position at Nth Scan Solution

Follow our step by step solution on how to calculate Measured Position at Nth Scan?

FIRST Step Consider the formula
xn=(Xin-xpnα)+xpn
Next Step Substitute values of Variables
xn=(40m-74m0.5)+74m
Next Step Prepare to Evaluate
xn=(40-740.5)+74
LAST Step Evaluate
xn=6m

Measured Position at Nth Scan Formula Elements

Variables
Measured Position at Nth Scan
Measured position at Nth scan is the measured or actual position of target at the nth scan by the track-while-scan surveillance radar.
Symbol: xn
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Smoothed Position
Smoothed Position is defined as the estimated present position of target by track-while-scan surveillance radar.
Symbol: Xin
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Target Predicted Position
Target Predicted Position is the predicted or estimated position of target at the nth scan by the track-while-scan surveillance radar.
Symbol: xpn
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Position Smoothing Parameter
Position Smoothing Parameter is the tuning parameter which is used to improve the quality of smoothed position estimated by the track-while-scan surveillance radar to avoid noisy measurements.
Symbol: α
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Special Purpose Radars category

​Go Doppler Frequency Shift
Δfd=2vtλ
​Go Reference Voltage of CW Oscillator
Vref=Arefsin(2πωT)
​Go Amplitude of Reference Signal
Aref=Vrefsin(2πωT)
​Go Amplitude of Signal Received from Target at Range
Arec=Vechosin((2π(fc+Δfd)T)-(4πfcRo[c]))

How to Evaluate Measured Position at Nth Scan?

Measured Position at Nth Scan evaluator uses Measured Position at Nth Scan = ((Smoothed Position-Target Predicted Position)/Position Smoothing Parameter)+Target Predicted Position to evaluate the Measured Position at Nth Scan, The Measured position at nth scan formula is defined as last position or nth position scanned in radar system. Measured Position at Nth Scan is denoted by xn symbol.

How to evaluate Measured Position at Nth Scan using this online evaluator? To use this online evaluator for Measured Position at Nth Scan, enter Smoothed Position (Xin), Target Predicted Position (xpn) & Position Smoothing Parameter (α) and hit the calculate button.

FAQs on Measured Position at Nth Scan

What is the formula to find Measured Position at Nth Scan?
The formula of Measured Position at Nth Scan is expressed as Measured Position at Nth Scan = ((Smoothed Position-Target Predicted Position)/Position Smoothing Parameter)+Target Predicted Position. Here is an example- 6 = ((40-74)/0.5)+74.
How to calculate Measured Position at Nth Scan?
With Smoothed Position (Xin), Target Predicted Position (xpn) & Position Smoothing Parameter (α) we can find Measured Position at Nth Scan using the formula - Measured Position at Nth Scan = ((Smoothed Position-Target Predicted Position)/Position Smoothing Parameter)+Target Predicted Position.
Can the Measured Position at Nth Scan be negative?
No, the Measured Position at Nth Scan, measured in Length cannot be negative.
Which unit is used to measure Measured Position at Nth Scan?
Measured Position at Nth Scan is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Measured Position at Nth Scan can be measured.
Copied!