Fx Copy
LaTeX Copy
Mean Velocity Gradient refers to the rate of change of velocity within a fluid over a specified distance or depth. Check FAQs
G=PμviscosityV
G - Mean Velocity Gradient?P - Power Requirement?μviscosity - Dynamic Viscosity?V - Volume of Tank?

Mean Velocity Gradient given Power Requirement for Flocculation Example

With values
With units
Only example

Here is how the Mean Velocity Gradient given Power Requirement for Flocculation equation looks like with Values.

Here is how the Mean Velocity Gradient given Power Requirement for Flocculation equation looks like with Units.

Here is how the Mean Velocity Gradient given Power Requirement for Flocculation equation looks like.

2Edit=3Edit833.33Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Mean Velocity Gradient given Power Requirement for Flocculation

Mean Velocity Gradient given Power Requirement for Flocculation Solution

Follow our step by step solution on how to calculate Mean Velocity Gradient given Power Requirement for Flocculation?

FIRST Step Consider the formula
G=PμviscosityV
Next Step Substitute values of Variables
G=3kJ/s833.33P9
Next Step Convert Units
G=3000W83.333Pa*s9
Next Step Prepare to Evaluate
G=300083.3339
Next Step Evaluate
G=2.000004000012s⁻¹
LAST Step Rounding Answer
G=2s⁻¹

Mean Velocity Gradient given Power Requirement for Flocculation Formula Elements

Variables
Functions
Mean Velocity Gradient
Mean Velocity Gradient refers to the rate of change of velocity within a fluid over a specified distance or depth.
Symbol: G
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value should be greater than 0.
Power Requirement
Power Requirement refers to the amount of energy needed to operate various processes, systems, or equipment involved in environmental management.
Symbol: P
Measurement: PowerUnit: kJ/s
Note: Value should be greater than 0.
Dynamic Viscosity
Dynamic Viscosity refers to a measure of a fluid's resistance to flow under an applied force or shear stress.
Symbol: μviscosity
Measurement: Dynamic ViscosityUnit: P
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank refers to the total capacity or size of a tank used for storing liquids, such as water, chemicals, or wastewater.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Mean Velocity Gradient

​Go Mean Velocity Gradient given Power Requirement
G=PμviscosityV
​Go Mean Velocity Gradient given Power Requirement for Rapid Mixing Operations
G=PμviscosityV

Other formulas in Design of Rapid Mix Basin and Flocculation Basin category

​Go Volume of Rapid Mix Basin
Vrapid=θW
​Go Hydraulic Retention Time given Volume of Rapid Mix Basin
θs=VrapidQFr'
​Go Wastewater Flow given Volume of Rapid Mix Basin
W=Vrapidθ
​Go Power Requirement given Mean Velocity Gradient
P=(G)2μviscosityV

How to Evaluate Mean Velocity Gradient given Power Requirement for Flocculation?

Mean Velocity Gradient given Power Requirement for Flocculation evaluator uses Mean Velocity Gradient = sqrt(Power Requirement/(Dynamic Viscosity*Volume of Tank)) to evaluate the Mean Velocity Gradient, The Mean Velocity Gradient given Power Requirement for Flocculation is defined as the rate of energy dissipation within the system, influencing the formation and stability of flocs, when we have prior information of the power requirement. Mean Velocity Gradient is denoted by G symbol.

How to evaluate Mean Velocity Gradient given Power Requirement for Flocculation using this online evaluator? To use this online evaluator for Mean Velocity Gradient given Power Requirement for Flocculation, enter Power Requirement (P), Dynamic Viscosity viscosity) & Volume of Tank (V) and hit the calculate button.

FAQs on Mean Velocity Gradient given Power Requirement for Flocculation

What is the formula to find Mean Velocity Gradient given Power Requirement for Flocculation?
The formula of Mean Velocity Gradient given Power Requirement for Flocculation is expressed as Mean Velocity Gradient = sqrt(Power Requirement/(Dynamic Viscosity*Volume of Tank)). Here is an example- 18.07754 = sqrt(3000/(83.333*9)).
How to calculate Mean Velocity Gradient given Power Requirement for Flocculation?
With Power Requirement (P), Dynamic Viscosity viscosity) & Volume of Tank (V) we can find Mean Velocity Gradient given Power Requirement for Flocculation using the formula - Mean Velocity Gradient = sqrt(Power Requirement/(Dynamic Viscosity*Volume of Tank)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Mean Velocity Gradient?
Here are the different ways to Calculate Mean Velocity Gradient-
  • Mean Velocity Gradient=sqrt(Power Requirement/(Dynamic Viscosity*Volume of Tank))OpenImg
  • Mean Velocity Gradient=sqrt(Power Requirement/(Dynamic Viscosity*Volume of Tank))OpenImg
Can the Mean Velocity Gradient given Power Requirement for Flocculation be negative?
No, the Mean Velocity Gradient given Power Requirement for Flocculation, measured in First Order Reaction Rate Constant cannot be negative.
Which unit is used to measure Mean Velocity Gradient given Power Requirement for Flocculation?
Mean Velocity Gradient given Power Requirement for Flocculation is usually measured using the 1 Per Second[s⁻¹] for First Order Reaction Rate Constant. 1 Per Millisecond[s⁻¹], 1 Per Day[s⁻¹], 1 Per Hour[s⁻¹] are the few other units in which Mean Velocity Gradient given Power Requirement for Flocculation can be measured.
Copied!