Fx Copy
LaTeX Copy
Maximum Voltage the highest voltage rating for electrical devices. Check FAQs
Vm=6Vrms
Vm - Maximum Voltage?Vrms - Root Mean Square Voltage?

Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) equation looks like with Values.

Here is how the Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) equation looks like with Units.

Here is how the Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) equation looks like.

17.1464Edit=67Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)

Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)?

FIRST Step Consider the formula
Vm=6Vrms
Next Step Substitute values of Variables
Vm=67V
Next Step Prepare to Evaluate
Vm=67
Next Step Evaluate
Vm=17.1464281994822V
LAST Step Rounding Answer
Vm=17.1464V

Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) Formula Elements

Variables
Functions
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Root Mean Square Voltage
Root Mean Square Voltage is the square root of the time average of the voltage squared.
Symbol: Vrms
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Maximum Voltage

​Go Maximum Voltage using Volume of Conductor Material(DC Three-Wire US)
Vm=5ρ(Pl)2PlineV
​Go Maximum Voltage using Area of X-Section (DC Three-Wire US)
Vm=2(P2)ρlPlineA
​Go Maximum Voltage using Line Losses (DC Three-Wire US)
Vm=2(P2)R1Pline
​Go Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US)
Vm=6ρ(Pl)2PlineV(cos(θ))2

Other formulas in Current and Voltage category

​Go Load Current using Line Losses (DC Three-Wire US)
C1=Pline2R1
​Go Maximum Voltage between Each Phase and Neutral (3-Phase 3-Wire US)
Vm(phase)=Vm3
​Go RMS Voltage Per Phase (3-Phase 3-Wire US)
Vrms=Vm6
​Go Load Current Per Phase (3-Phase 3-Wire US)
C1=6P3Vmcos(θ)

How to Evaluate Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)?

Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) evaluator uses Maximum Voltage = sqrt(6)*Root Mean Square Voltage to evaluate the Maximum Voltage, The Maximum Voltage using RMS Voltage Per Phase (3-phase 3-wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition. Maximum Voltage is denoted by Vm symbol.

How to evaluate Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US), enter Root Mean Square Voltage (Vrms) and hit the calculate button.

FAQs on Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)

What is the formula to find Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)?
The formula of Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) is expressed as Maximum Voltage = sqrt(6)*Root Mean Square Voltage. Here is an example- 17.14643 = sqrt(6)*7.
How to calculate Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)?
With Root Mean Square Voltage (Vrms) we can find Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) using the formula - Maximum Voltage = sqrt(6)*Root Mean Square Voltage. This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Maximum Voltage?
Here are the different ways to Calculate Maximum Voltage-
  • Maximum Voltage=sqrt(5*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor))OpenImg
  • Maximum Voltage=sqrt(2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*Area of underground dc wire))OpenImg
  • Maximum Voltage=sqrt(2*(Power Transmitted^2)*Resistance underground DC/(Line Losses))OpenImg
Can the Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) be negative?
Yes, the Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US), measured in Electric Potential can be negative.
Which unit is used to measure Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US)?
Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Voltage using RMS Voltage Per Phase (3-Phase 3-Wire US) can be measured.
Copied!