Fx Copy
LaTeX Copy
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire. Check FAQs
Vm=2PIcos(Φ)
Vm - Maximum Voltage Underground AC?P - Power Transmitted?I - Current Underground AC?Φ - Phase Difference?

Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

54.4331Edit=2300Edit9Editcos(30Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)

Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
Vm=2PIcos(Φ)
Next Step Substitute values of Variables
Vm=2300W9Acos(30°)
Next Step Convert Units
Vm=2300W9Acos(0.5236rad)
Next Step Prepare to Evaluate
Vm=23009cos(0.5236)
Next Step Evaluate
Vm=54.4331053951817V
LAST Step Rounding Answer
Vm=54.4331V

Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Functions
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Maximum Voltage Underground AC

​Go Maximum Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))RPloss
​Go Maximum Voltage using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))ρLAPloss

Other formulas in Current and Voltage category

​Go Load Current (1-Phase 2-Wire Mid-Point Earthed)
I=2PVmcos(Φ)
​Go Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
I=Ploss2R
​Go RMS Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Vrms=PIcos(Φ)
​Go RMS Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Vrms=(Pcos(Φ))2RPloss

How to Evaluate Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Maximum Voltage Underground AC = (sqrt(2)*Power Transmitted)/(Current Underground AC*cos(Phase Difference)) to evaluate the Maximum Voltage Underground AC, The Maximum Voltage using Load Current (1-phase 2-wire Mid-point Earthed) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition. Maximum Voltage Underground AC is denoted by Vm symbol.

How to evaluate Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed), enter Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ) and hit the calculate button.

FAQs on Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) is expressed as Maximum Voltage Underground AC = (sqrt(2)*Power Transmitted)/(Current Underground AC*cos(Phase Difference)). Here is an example- 54.43311 = (sqrt(2)*300)/(9*cos(0.5235987755982)).
How to calculate Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
With Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ) we can find Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) using the formula - Maximum Voltage Underground AC = (sqrt(2)*Power Transmitted)/(Current Underground AC*cos(Phase Difference)). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Maximum Voltage Underground AC?
Here are the different ways to Calculate Maximum Voltage Underground AC-
  • Maximum Voltage Underground AC=((2*Power Transmitted)/cos(Phase Difference))*sqrt(Resistance Underground AC/Line Losses)OpenImg
  • Maximum Voltage Underground AC=((2*Power Transmitted)/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(Area of Underground AC Wire*Line Losses))OpenImg
Can the Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) be negative?
Yes, the Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed), measured in Electric Potential can be negative.
Which unit is used to measure Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!