Maximum Voltage using Area of X-Section(DC Two-Wire OS) Formula

Fx Copy
LaTeX Copy
Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire. Check FAQs
Vm=(P2)ρLAPloss
Vm - Maximum Voltage Overhead DC?P - Power Transmitted?ρ - Resistivity?L - Length of Wire DC?A - Area of Overhead DC Wire?Ploss - Line Losses?

Maximum Voltage using Area of X-Section(DC Two-Wire OS) Example

With values
With units
Only example

Here is how the Maximum Voltage using Area of X-Section(DC Two-Wire OS) equation looks like with Values.

Here is how the Maximum Voltage using Area of X-Section(DC Two-Wire OS) equation looks like with Units.

Here is how the Maximum Voltage using Area of X-Section(DC Two-Wire OS) equation looks like.

19.4913Edit=(920Edit2)1.7E-5Edit12.7Edit0.65Edit0.74Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Maximum Voltage using Area of X-Section(DC Two-Wire OS)

Maximum Voltage using Area of X-Section(DC Two-Wire OS) Solution

Follow our step by step solution on how to calculate Maximum Voltage using Area of X-Section(DC Two-Wire OS)?

FIRST Step Consider the formula
Vm=(P2)ρLAPloss
Next Step Substitute values of Variables
Vm=(920W2)1.7E-5Ω*m12.7m0.650.74W
Next Step Prepare to Evaluate
Vm=(9202)1.7E-512.70.650.74
Next Step Evaluate
Vm=19.4913360997183V
LAST Step Rounding Answer
Vm=19.4913V

Maximum Voltage using Area of X-Section(DC Two-Wire OS) Formula Elements

Variables
Functions
Maximum Voltage Overhead DC
Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Wire DC
Length of Wire DC is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Overhead DC Wire
Area of Overhead DC Wire is defined as the cross-sectional area of the wire of an overhead DC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in 2 Wire System category

​Go Resistance(2-Wire DC OS)
R=ρLA
​Go Load Current using Line Losses(DC Two-Wire OS)
I=Ploss2R
​Go Length using Volume of Conductor Material (DC 2-Wire OS)
L=VPlossVm2(4)ρ(P2)
​Go Line Losses using Volume of Conductor Material (DC 2-Wire OS)
Ploss=4ρ(PL)2V(Vm2)

How to Evaluate Maximum Voltage using Area of X-Section(DC Two-Wire OS)?

Maximum Voltage using Area of X-Section(DC Two-Wire OS) evaluator uses Maximum Voltage Overhead DC = sqrt((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*Line Losses)) to evaluate the Maximum Voltage Overhead DC, The Maximum Voltage using Area of X-section(DC Two-Wire OS) formula is defined as the absolute maximum rated supply voltage is the maximum voltage that can be supplied between the positive supply (VCC) and negative supply (VEE) pins without causing characteristics degradation or damage to the internal circuit. Maximum Voltage Overhead DC is denoted by Vm symbol.

How to evaluate Maximum Voltage using Area of X-Section(DC Two-Wire OS) using this online evaluator? To use this online evaluator for Maximum Voltage using Area of X-Section(DC Two-Wire OS), enter Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Area of Overhead DC Wire (A) & Line Losses (Ploss) and hit the calculate button.

FAQs on Maximum Voltage using Area of X-Section(DC Two-Wire OS)

What is the formula to find Maximum Voltage using Area of X-Section(DC Two-Wire OS)?
The formula of Maximum Voltage using Area of X-Section(DC Two-Wire OS) is expressed as Maximum Voltage Overhead DC = sqrt((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*Line Losses)). Here is an example- 19.49134 = sqrt((920^2)*1.7E-05*12.7/(0.65*0.74)).
How to calculate Maximum Voltage using Area of X-Section(DC Two-Wire OS)?
With Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Area of Overhead DC Wire (A) & Line Losses (Ploss) we can find Maximum Voltage using Area of X-Section(DC Two-Wire OS) using the formula - Maximum Voltage Overhead DC = sqrt((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*Line Losses)). This formula also uses Square Root (sqrt) function(s).
Can the Maximum Voltage using Area of X-Section(DC Two-Wire OS) be negative?
Yes, the Maximum Voltage using Area of X-Section(DC Two-Wire OS), measured in Electric Potential can be negative.
Which unit is used to measure Maximum Voltage using Area of X-Section(DC Two-Wire OS)?
Maximum Voltage using Area of X-Section(DC Two-Wire OS) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Voltage using Area of X-Section(DC Two-Wire OS) can be measured.
Copied!