Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Formula

Fx Copy
LaTeX Copy
Peak Output Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a thyristor based converter circuit. Check FAQs
Vom(thy)=Vin(thy)π
Vom(thy) - Peak Output Voltage Thyristor Converter?Vin(thy) - Peak Input Voltage Thyristor Converter?π - Archimedes' constant?

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Example

With values
With units
Only example

Here is how the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like with Values.

Here is how the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like with Units.

Here is how the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like.

3.8197Edit=12Edit3.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Solution

Follow our step by step solution on how to calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?

FIRST Step Consider the formula
Vom(thy)=Vin(thy)π
Next Step Substitute values of Variables
Vom(thy)=12Vπ
Next Step Substitute values of Constants
Vom(thy)=12V3.1416
Next Step Prepare to Evaluate
Vom(thy)=123.1416
Next Step Evaluate
Vom(thy)=3.81971863420549V
LAST Step Rounding Answer
Vom(thy)=3.8197V

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Formula Elements

Variables
Constants
Peak Output Voltage Thyristor Converter
Peak Output Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a thyristor based converter circuit.
Symbol: Vom(thy)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Peak Input Voltage Thyristor Converter
Peak Input Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a thyristor based converter circuit.
Symbol: Vin(thy)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Single Phase Thyristor Converter category

​Go Average Output Voltage of Single Phase Thyristor Converter with Resistive Load
Vavg(thy)=(Vin(thy)2π)(1+cos(αd(thy)))
​Go Normalized Voltage of Single Phase Thyristor Converter with Resistive Load
Vn(thy)=0.5(1+cos(αd(thy)))
​Go RMS Output Voltage of Single Phase Thyristor Converter with Resistive Load
Vrms(thy)=(Vin(thy)2)(180-αd(thy)180+(0.5π)sin(2αd(thy)))0.5
​Go Average Load Voltage for Calculus Function
Vavg(thy)=((12π)(Vin(thy)sin(x),x,αf(thy),π))

How to Evaluate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load evaluator uses Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi to evaluate the Peak Output Voltage Thyristor Converter, The Maximum output voltage of single phase thyristor converter with resistive load is the ratio of peak input voltage and pi = 3.14. Peak Output Voltage Thyristor Converter is denoted by Vom(thy) symbol.

How to evaluate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load using this online evaluator? To use this online evaluator for Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load, enter Peak Input Voltage Thyristor Converter (Vin(thy)) and hit the calculate button.

FAQs on Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load

What is the formula to find Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?
The formula of Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load is expressed as Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi. Here is an example- 3.819719 = 12/pi.
How to calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?
With Peak Input Voltage Thyristor Converter (Vin(thy)) we can find Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load using the formula - Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi. This formula also uses Archimedes' constant .
Can the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load be negative?
Yes, the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load, measured in Electric Potential can be negative.
Which unit is used to measure Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?
Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load can be measured.
Copied!