Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load Formula

Fx Copy
LaTeX Copy
Peak Output Voltage Semi Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a semi converter circuit. Check FAQs
Vom(semi)=2Vm(semi)π
Vom(semi) - Peak Output Voltage Semi Converter?Vm(semi) - Maximum Input Voltage Semi Converter?π - Archimedes' constant?

Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load Example

With values
With units
Only example

Here is how the Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load equation looks like with Values.

Here is how the Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load equation looks like with Units.

Here is how the Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load equation looks like.

14.5149Edit=222.8Edit3.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load

Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load Solution

Follow our step by step solution on how to calculate Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load?

FIRST Step Consider the formula
Vom(semi)=2Vm(semi)π
Next Step Substitute values of Variables
Vom(semi)=222.8Vπ
Next Step Substitute values of Constants
Vom(semi)=222.8V3.1416
Next Step Prepare to Evaluate
Vom(semi)=222.83.1416
Next Step Evaluate
Vom(semi)=14.5149308099809V
LAST Step Rounding Answer
Vom(semi)=14.5149V

Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load Formula Elements

Variables
Constants
Peak Output Voltage Semi Converter
Peak Output Voltage Semi Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a semi converter circuit.
Symbol: Vom(semi)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Maximum Input Voltage Semi Converter
Maximum Input Voltage Semi Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a semi converter circuit.
Symbol: Vm(semi)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Single Phase Semi Converter category

​Go Average Output Voltage of Single Phase Semi-Converter with Highly Inductive Load
Vavg(semi)=(Vm(semi)π)(1+cos(α(semi)))
​Go RMS Output Voltage of Single Phase Semi-Converter with Highly Inductive Load
Vrms(semi)=(Vm(semi)20.5)(180-α(semi)180+(0.5π)sin(2α(semi)))0.5
​Go Displacement Power Factor for Constant Load Current
cosΦdisp(semi)t=cos(α(semi)2)
​Go Distortion Power Factor for Constant Load Current
cosΦdistort=0.9(cos(α(semi)2))(180-α(semi)180)0.5

How to Evaluate Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load?

Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load evaluator uses Peak Output Voltage Semi Converter = (2*Maximum Input Voltage Semi Converter)/pi to evaluate the Peak Output Voltage Semi Converter, The Maximum output voltage of single phase semi-converter with highly inductive load formula is twice the ratio of peak input voltage and pi = 3.14. Peak Output Voltage Semi Converter is denoted by Vom(semi) symbol.

How to evaluate Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load using this online evaluator? To use this online evaluator for Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load, enter Maximum Input Voltage Semi Converter (Vm(semi)) and hit the calculate button.

FAQs on Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load

What is the formula to find Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load?
The formula of Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load is expressed as Peak Output Voltage Semi Converter = (2*Maximum Input Voltage Semi Converter)/pi. Here is an example- 14.45127 = (2*22.8)/pi.
How to calculate Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load?
With Maximum Input Voltage Semi Converter (Vm(semi)) we can find Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load using the formula - Peak Output Voltage Semi Converter = (2*Maximum Input Voltage Semi Converter)/pi. This formula also uses Archimedes' constant .
Can the Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load be negative?
Yes, the Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load, measured in Electric Potential can be negative.
Which unit is used to measure Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load?
Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Output Voltage of Single Phase Semi-Converter with Highly Inductive Load can be measured.
Copied!