Fx Copy
LaTeX Copy
Peak Frequency is the highest frequency of a band-limited continuous-time signal in an inverter based circuit. Check FAQs
fm=12toff
fm - Peak Frequency?toff - Off Time of Thyristor?

Maximum Output Frequency for Bidirectional Switches Example

With values
With units
Only example

Here is how the Maximum Output Frequency for Bidirectional Switches equation looks like with Values.

Here is how the Maximum Output Frequency for Bidirectional Switches equation looks like with Units.

Here is how the Maximum Output Frequency for Bidirectional Switches equation looks like.

0.25Edit=122Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Maximum Output Frequency for Bidirectional Switches

Maximum Output Frequency for Bidirectional Switches Solution

Follow our step by step solution on how to calculate Maximum Output Frequency for Bidirectional Switches?

FIRST Step Consider the formula
fm=12toff
Next Step Substitute values of Variables
fm=122s
Next Step Prepare to Evaluate
fm=122
LAST Step Evaluate
fm=0.25Hz

Maximum Output Frequency for Bidirectional Switches Formula Elements

Variables
Peak Frequency
Peak Frequency is the highest frequency of a band-limited continuous-time signal in an inverter based circuit.
Symbol: fm
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.
Off Time of Thyristor
Off time of thyristor is the duration for which the thyristor is in the off state and it is also called the dead zone.
Symbol: toff
Measurement: TimeUnit: s
Note: Value should be greater than 0.

Other Formulas to find Peak Frequency

​Go Maximum Output Frequency for Unidirectional Switches
fm=12(toff+(πfο))

Other formulas in Series Resonant Inverter category

​Go Resonant Frequency for Unidirectional Switches
fο=((1LC)+(R24L2))0.5
​Go Time when Current becomes Maximum for Unidirectional Switches
tr=(1fο)atan(fο2LR)

How to Evaluate Maximum Output Frequency for Bidirectional Switches?

Maximum Output Frequency for Bidirectional Switches evaluator uses Peak Frequency = 1/(2*Off Time of Thyristor) to evaluate the Peak Frequency, The Maximum output frequency for bidirectional switches formula is the maximum possible output frequency for the series resonant inverter with bidirectional switches taking into consideration the details of all the equipment used. Peak Frequency is denoted by fm symbol.

How to evaluate Maximum Output Frequency for Bidirectional Switches using this online evaluator? To use this online evaluator for Maximum Output Frequency for Bidirectional Switches, enter Off Time of Thyristor (toff) and hit the calculate button.

FAQs on Maximum Output Frequency for Bidirectional Switches

What is the formula to find Maximum Output Frequency for Bidirectional Switches?
The formula of Maximum Output Frequency for Bidirectional Switches is expressed as Peak Frequency = 1/(2*Off Time of Thyristor). Here is an example- 0.25 = 1/(2*2).
How to calculate Maximum Output Frequency for Bidirectional Switches?
With Off Time of Thyristor (toff) we can find Maximum Output Frequency for Bidirectional Switches using the formula - Peak Frequency = 1/(2*Off Time of Thyristor).
What are the other ways to Calculate Peak Frequency?
Here are the different ways to Calculate Peak Frequency-
  • Peak Frequency=1/(2*(Off Time of Thyristor+(pi/Resonant Frequency)))OpenImg
Can the Maximum Output Frequency for Bidirectional Switches be negative?
No, the Maximum Output Frequency for Bidirectional Switches, measured in Frequency cannot be negative.
Which unit is used to measure Maximum Output Frequency for Bidirectional Switches?
Maximum Output Frequency for Bidirectional Switches is usually measured using the Hertz[Hz] for Frequency. Petahertz[Hz], Terahertz[Hz], Gigahertz[Hz] are the few other units in which Maximum Output Frequency for Bidirectional Switches can be measured.
Copied!