Maximum Moment for Symmetrical Concrete Wall Footing evaluator uses Maximum Moment = (Uniform Pressure on Soil/8)*(Width of Footing-Wall Thickness)^2 to evaluate the Maximum Moment, The Maximum Moment for Symmetrical Concrete Wall Footing formula is defined as the maximum moment occur due to the uniform pressure on the soil by the wall footing. Maximum Moment is denoted by M'max symbol.
How to evaluate Maximum Moment for Symmetrical Concrete Wall Footing using this online evaluator? To use this online evaluator for Maximum Moment for Symmetrical Concrete Wall Footing, enter Uniform Pressure on Soil (P), Width of Footing (b) & Wall Thickness (t) and hit the calculate button.