Maximum Moment for Symmetrical Concrete Wall Footing Formula

Fx Copy
LaTeX Copy
The maximum Moment is the absolute value of the maximum moment in the unbraced beam segment. Check FAQs
M'max=(P8)(b-t)2
M'max - Maximum Moment?P - Uniform Pressure on Soil?b - Width of Footing?t - Wall Thickness?

Maximum Moment for Symmetrical Concrete Wall Footing Example

With values
With units
Only example

Here is how the Maximum Moment for Symmetrical Concrete Wall Footing equation looks like with Values.

Here is how the Maximum Moment for Symmetrical Concrete Wall Footing equation looks like with Units.

Here is how the Maximum Moment for Symmetrical Concrete Wall Footing equation looks like.

85.6411Edit=(11.7686Edit8)(0.2Edit-7.83Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Maximum Moment for Symmetrical Concrete Wall Footing

Maximum Moment for Symmetrical Concrete Wall Footing Solution

Follow our step by step solution on how to calculate Maximum Moment for Symmetrical Concrete Wall Footing?

FIRST Step Consider the formula
M'max=(P8)(b-t)2
Next Step Substitute values of Variables
M'max=(11.7686Pa8)(0.2m-7.83m)2
Next Step Prepare to Evaluate
M'max=(11.76868)(0.2-7.83)2
Next Step Evaluate
M'max=85.641062311875N*m
LAST Step Rounding Answer
M'max=85.6411N*m

Maximum Moment for Symmetrical Concrete Wall Footing Formula Elements

Variables
Maximum Moment
The maximum Moment is the absolute value of the maximum moment in the unbraced beam segment.
Symbol: M'max
Measurement: Moment of ForceUnit: N*m
Note: Value should be greater than 0.
Uniform Pressure on Soil
Uniform Pressure on Soil is described as the pressure incurred at the soil under the wall footing.
Symbol: P
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Width of Footing
Width of Footing is the shorter dimension of the footing.
Symbol: b
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Wall Thickness
Wall Thickness is simply the width of the wall that we are taking under consideration.
Symbol: t
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Footing category

​Go Uniform Pressure on Soil given Maximum Moment
P=8M'max(b-t)2
​Go Tensile Bending Stress at Bottom when Footing is Deep
B=(6MD2)

How to Evaluate Maximum Moment for Symmetrical Concrete Wall Footing?

Maximum Moment for Symmetrical Concrete Wall Footing evaluator uses Maximum Moment = (Uniform Pressure on Soil/8)*(Width of Footing-Wall Thickness)^2 to evaluate the Maximum Moment, The Maximum Moment for Symmetrical Concrete Wall Footing formula is defined as the maximum moment occur due to the uniform pressure on the soil by the wall footing. Maximum Moment is denoted by M'max symbol.

How to evaluate Maximum Moment for Symmetrical Concrete Wall Footing using this online evaluator? To use this online evaluator for Maximum Moment for Symmetrical Concrete Wall Footing, enter Uniform Pressure on Soil (P), Width of Footing (b) & Wall Thickness (t) and hit the calculate button.

FAQs on Maximum Moment for Symmetrical Concrete Wall Footing

What is the formula to find Maximum Moment for Symmetrical Concrete Wall Footing?
The formula of Maximum Moment for Symmetrical Concrete Wall Footing is expressed as Maximum Moment = (Uniform Pressure on Soil/8)*(Width of Footing-Wall Thickness)^2. Here is an example- 85.64106 = (11.76855/8)*(0.2-7.83)^2.
How to calculate Maximum Moment for Symmetrical Concrete Wall Footing?
With Uniform Pressure on Soil (P), Width of Footing (b) & Wall Thickness (t) we can find Maximum Moment for Symmetrical Concrete Wall Footing using the formula - Maximum Moment = (Uniform Pressure on Soil/8)*(Width of Footing-Wall Thickness)^2.
Can the Maximum Moment for Symmetrical Concrete Wall Footing be negative?
No, the Maximum Moment for Symmetrical Concrete Wall Footing, measured in Moment of Force cannot be negative.
Which unit is used to measure Maximum Moment for Symmetrical Concrete Wall Footing?
Maximum Moment for Symmetrical Concrete Wall Footing is usually measured using the Newton Meter[N*m] for Moment of Force. Kilonewton Meter[N*m], Millinewton Meter[N*m], Micronewton Meter[N*m] are the few other units in which Maximum Moment for Symmetrical Concrete Wall Footing can be measured.
Copied!