Maximum Junction Temperature of TRIAC Formula

Fx Copy
LaTeX Copy
Maximum Operating Junction TRIAC (TJmax) of an IGBT is the highest temperature at which the IGBT can safely operate. It is typically specified in degrees Celsius (°C). Check FAQs
Tjmax(triac)=Ta(triac)+P(triac)Rth(j-a)(triac)
Tjmax(triac) - Maximum Operating Junction TRIAC?Ta(triac) - Ambient Temperature TRIAC?P(triac) - Dissipation Power TRIAC?Rth(j-a)(triac) - Junction to Ambient Thermal Resistance TRIAC?

Maximum Junction Temperature of TRIAC Example

With values
With units
Only example

Here is how the Maximum Junction Temperature of TRIAC equation looks like with Values.

Here is how the Maximum Junction Temperature of TRIAC equation looks like with Units.

Here is how the Maximum Junction Temperature of TRIAC equation looks like.

196.12Edit=102.4Edit+0.66Edit0.142Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Maximum Junction Temperature of TRIAC

Maximum Junction Temperature of TRIAC Solution

Follow our step by step solution on how to calculate Maximum Junction Temperature of TRIAC?

FIRST Step Consider the formula
Tjmax(triac)=Ta(triac)+P(triac)Rth(j-a)(triac)
Next Step Substitute values of Variables
Tjmax(triac)=102.4°C+0.66W0.142
Next Step Convert Units
Tjmax(triac)=375.55K+0.66W142Ω
Next Step Prepare to Evaluate
Tjmax(triac)=375.55+0.66142
Next Step Evaluate
Tjmax(triac)=469.27K
LAST Step Convert to Output's Unit
Tjmax(triac)=196.12°C

Maximum Junction Temperature of TRIAC Formula Elements

Variables
Maximum Operating Junction TRIAC
Maximum Operating Junction TRIAC (TJmax) of an IGBT is the highest temperature at which the IGBT can safely operate. It is typically specified in degrees Celsius (°C).
Symbol: Tjmax(triac)
Measurement: TemperatureUnit: °C
Note: Value should be greater than 0.
Ambient Temperature TRIAC
Ambient Temperature TRIAC are designed to operate in high ambient temperatures. They have a higher junction temperature rating than standard triac.
Symbol: Ta(triac)
Measurement: TemperatureUnit: °C
Note: Value should be greater than 0.
Dissipation Power TRIAC
Dissipation Power triac is the amount of heat that is generated by the triac when it is conducting current.
Symbol: P(triac)
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Junction to Ambient Thermal Resistance TRIAC
Junction to Ambient Thermal Resistance TRIAC (R) is the measure of how well the TRIAC dissipates heat from its junction to the ambient air.
Symbol: Rth(j-a)(triac)
Measurement: Electric ResistanceUnit:
Note: Value should be greater than 0.

Other formulas in TRIAC category

​Go Average Load Current of TRIAC
Iavg(triac)=22Irms(triac)π
​Go Power Dissipation of TRIAC
Pmax(triac)=Vknee(triac)Iavg(triac)+Rs(triac)Irms(triac)2
​Go RMS Load Current of TRIAC
Irms(triac)=Ipeak(triac)2

How to Evaluate Maximum Junction Temperature of TRIAC?

Maximum Junction Temperature of TRIAC evaluator uses Maximum Operating Junction TRIAC = Ambient Temperature TRIAC+Dissipation Power TRIAC*Junction to Ambient Thermal Resistance TRIAC to evaluate the Maximum Operating Junction TRIAC, Maximum Junction Temperature of TRIAC is the highest temperature that the triac's junction can withstand without being damaged. The maximum junction temperature is an important parameter to consider when designing a triac circuit, as it determines the maximum power that the triac can dissipate without overheating. If the triac's junction temperature exceeds its maximum rating, it may fail. Maximum Operating Junction TRIAC is denoted by Tjmax(triac) symbol.

How to evaluate Maximum Junction Temperature of TRIAC using this online evaluator? To use this online evaluator for Maximum Junction Temperature of TRIAC, enter Ambient Temperature TRIAC (Ta(triac)), Dissipation Power TRIAC (P(triac)) & Junction to Ambient Thermal Resistance TRIAC (Rth(j-a)(triac)) and hit the calculate button.

FAQs on Maximum Junction Temperature of TRIAC

What is the formula to find Maximum Junction Temperature of TRIAC?
The formula of Maximum Junction Temperature of TRIAC is expressed as Maximum Operating Junction TRIAC = Ambient Temperature TRIAC+Dissipation Power TRIAC*Junction to Ambient Thermal Resistance TRIAC. Here is an example- -76.70462 = 375.55+0.66*142.
How to calculate Maximum Junction Temperature of TRIAC?
With Ambient Temperature TRIAC (Ta(triac)), Dissipation Power TRIAC (P(triac)) & Junction to Ambient Thermal Resistance TRIAC (Rth(j-a)(triac)) we can find Maximum Junction Temperature of TRIAC using the formula - Maximum Operating Junction TRIAC = Ambient Temperature TRIAC+Dissipation Power TRIAC*Junction to Ambient Thermal Resistance TRIAC.
Can the Maximum Junction Temperature of TRIAC be negative?
No, the Maximum Junction Temperature of TRIAC, measured in Temperature cannot be negative.
Which unit is used to measure Maximum Junction Temperature of TRIAC?
Maximum Junction Temperature of TRIAC is usually measured using the Celsius[°C] for Temperature. Kelvin[°C], Fahrenheit[°C], Rankine[°C] are the few other units in which Maximum Junction Temperature of TRIAC can be measured.
Copied!