Vcmr=Vt+VL-(12RL)
Vcmr - Common-Mode Range?Vt - Threshold Voltage?VL - Load Voltage?RL - Load Resistance?

Maximum Input Common-Mode Range of MOS Differential Amplifier Example

With values
With units
Only example

Here is how the Maximum Input Common-Mode Range of MOS Differential Amplifier equation looks like with Values.

Here is how the Maximum Input Common-Mode Range of MOS Differential Amplifier equation looks like with Units.

Here is how the Maximum Input Common-Mode Range of MOS Differential Amplifier equation looks like.

3.34Edit=19.5Edit+22.64Edit-(120.0776Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Amplifiers » fx Maximum Input Common-Mode Range of MOS Differential Amplifier

Maximum Input Common-Mode Range of MOS Differential Amplifier Solution

Follow our step by step solution on how to calculate Maximum Input Common-Mode Range of MOS Differential Amplifier?

FIRST Step Consider the formula
Vcmr=Vt+VL-(12RL)
Next Step Substitute values of Variables
Vcmr=19.5V+22.64V-(120.0776)
Next Step Convert Units
Vcmr=19.5V+22.64V-(1277.6Ω)
Next Step Prepare to Evaluate
Vcmr=19.5+22.64-(1277.6)
LAST Step Evaluate
Vcmr=3.34V

Maximum Input Common-Mode Range of MOS Differential Amplifier Formula Elements

Variables
Common-Mode Range
The common-mode range is for signal processing devices with differential inputs, such as an op-amp.
Symbol: Vcmr
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Threshold Voltage
Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals.
Symbol: Vt
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Load Voltage
The Load Voltage is defined as the voltage between two terminals of load.
Symbol: VL
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Load Resistance
Load resistance of MOSFET is the effective resistance of all of the circuit elements excluding the emf source.
Symbol: RL
Measurement: Electric ResistanceUnit:
Note: Value should be greater than 0.

Other Formulas to find Common-Mode Range

​Go Minimum Input Common-Mode Range of MOS Differential Amplifier
Vcmr=Vt+Vov+Vgs-VL

Other formulas in Differential Configuration category

​Go Input Voltage of MOS Differential Amplifier on Small-Signal Operation
Vin=Vcm+(12Vis)
​Go Input Offset Voltage of MOS Differential Amplifier
Vos=VoAd
​Go Input Offset Voltage of MOS Differential Amplifier when Aspect Ratio Mismatches
Vos=(Vov2)(WLWL1)
​Go Input Offset Voltage of MOS Differential Amplifier given Saturation Current
Vos=Vt(IscIs)

How to Evaluate Maximum Input Common-Mode Range of MOS Differential Amplifier?

Maximum Input Common-Mode Range of MOS Differential Amplifier evaluator uses Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance) to evaluate the Common-Mode Range, maximum input common-mode range of MOS differential amplifier formula is for signal processing devices with differential inputs, such as op-amp, CMVR is range of common-mode signal for which amplifier's operation remains linear. Common-Mode Range is denoted by Vcmr symbol.

How to evaluate Maximum Input Common-Mode Range of MOS Differential Amplifier using this online evaluator? To use this online evaluator for Maximum Input Common-Mode Range of MOS Differential Amplifier, enter Threshold Voltage (Vt), Load Voltage (VL) & Load Resistance (RL) and hit the calculate button.

FAQs on Maximum Input Common-Mode Range of MOS Differential Amplifier

What is the formula to find Maximum Input Common-Mode Range of MOS Differential Amplifier?
The formula of Maximum Input Common-Mode Range of MOS Differential Amplifier is expressed as Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance). Here is an example- 13.34 = 19.5+22.64-(1/2*77.6).
How to calculate Maximum Input Common-Mode Range of MOS Differential Amplifier?
With Threshold Voltage (Vt), Load Voltage (VL) & Load Resistance (RL) we can find Maximum Input Common-Mode Range of MOS Differential Amplifier using the formula - Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance).
What are the other ways to Calculate Common-Mode Range?
Here are the different ways to Calculate Common-Mode Range-
  • Common-Mode Range=Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load VoltageOpenImg
Can the Maximum Input Common-Mode Range of MOS Differential Amplifier be negative?
No, the Maximum Input Common-Mode Range of MOS Differential Amplifier, measured in Electric Potential cannot be negative.
Which unit is used to measure Maximum Input Common-Mode Range of MOS Differential Amplifier?
Maximum Input Common-Mode Range of MOS Differential Amplifier is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Maximum Input Common-Mode Range of MOS Differential Amplifier can be measured.
Copied!