Maximum Height of Water Table Formula

Fx Copy
LaTeX Copy
The Maximum Height of Water Table refers to the water table refers to the highest level at which the water table can be found in a given area. Check FAQs
hm=(L2)RK
hm - Maximum Height of Water Table?L - Length between Tile Drain?R - Natural Recharge?K - Coefficient of Permeability?

Maximum Height of Water Table Example

With values
With units
Only example

Here is how the Maximum Height of Water Table equation looks like with Values.

Here is how the Maximum Height of Water Table equation looks like with Units.

Here is how the Maximum Height of Water Table equation looks like.

40Edit=(6Edit2)16Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Maximum Height of Water Table

Maximum Height of Water Table Solution

Follow our step by step solution on how to calculate Maximum Height of Water Table?

FIRST Step Consider the formula
hm=(L2)RK
Next Step Substitute values of Variables
hm=(6m2)16m³/s9cm/s
Next Step Convert Units
hm=(6m2)16m³/s0.09m/s
Next Step Prepare to Evaluate
hm=(62)160.09
LAST Step Evaluate
hm=40m

Maximum Height of Water Table Formula Elements

Variables
Functions
Maximum Height of Water Table
The Maximum Height of Water Table refers to the water table refers to the highest level at which the water table can be found in a given area.
Symbol: hm
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Length between Tile Drain
The Length between Tile Drain refers to the approximate expression to the water table profile on a horizontal impervious boundary.
Symbol: L
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Natural Recharge
The Natural Recharge is a process by which groundwater is replenished naturally when precipitation infiltrates the ground, moving through the soil and rock layers until it reaches the water table.
Symbol: R
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability
The Coefficient of Permeability of soil describes how easily a liquid will move through the soil.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Unconfined Flow by Dupit's Assumption category

​Go Mass Flux Entering Element
Mx1=ρwaterVxHwΔy
​Go Discharge per Unit Width of Aquifer considering Permeability
Q=(ho2-h12)K2Lstream
​Go Water Table Profile Neglecting Depths of Water in Drains
h=(RK)(L-x)x
​Go Length when Discharge entering per Unit Length of Drain is Considered
L=QR

How to Evaluate Maximum Height of Water Table?

Maximum Height of Water Table evaluator uses Maximum Height of Water Table = (Length between Tile Drain/2)*sqrt(Natural Recharge/Coefficient of Permeability) to evaluate the Maximum Height of Water Table, The Maximum Height of Water Table is defined as the overall maximum height of the upper surface of the zone of saturation. The zone of saturation is where the pores and fractures of the ground are saturated with water. Maximum Height of Water Table is denoted by hm symbol.

How to evaluate Maximum Height of Water Table using this online evaluator? To use this online evaluator for Maximum Height of Water Table, enter Length between Tile Drain (L), Natural Recharge (R) & Coefficient of Permeability (K) and hit the calculate button.

FAQs on Maximum Height of Water Table

What is the formula to find Maximum Height of Water Table?
The formula of Maximum Height of Water Table is expressed as Maximum Height of Water Table = (Length between Tile Drain/2)*sqrt(Natural Recharge/Coefficient of Permeability). Here is an example- 40 = (6/2)*sqrt(16/0.09).
How to calculate Maximum Height of Water Table?
With Length between Tile Drain (L), Natural Recharge (R) & Coefficient of Permeability (K) we can find Maximum Height of Water Table using the formula - Maximum Height of Water Table = (Length between Tile Drain/2)*sqrt(Natural Recharge/Coefficient of Permeability). This formula also uses Square Root (sqrt) function(s).
Can the Maximum Height of Water Table be negative?
Yes, the Maximum Height of Water Table, measured in Length can be negative.
Which unit is used to measure Maximum Height of Water Table?
Maximum Height of Water Table is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Maximum Height of Water Table can be measured.
Copied!