Fx Copy
LaTeX Copy
The Head Loss is a measure of the reduction in the total head (sum of elevation head, velocity head and pressure head) of the fluid as it moves through a fluid system. Check FAQs
hL=0.0729((2v)2-u2)
hL - Head Loss?v - Velocity of Flow after Screening?u - Velocity of Flow before Screening?

Maximum Head Loss when screen is 50 percent clogged Example

With values
With units
Only example

Here is how the Maximum Head Loss when screen is 50 percent clogged equation looks like with Values.

Here is how the Maximum Head Loss when screen is 50 percent clogged equation looks like with Units.

Here is how the Maximum Head Loss when screen is 50 percent clogged equation looks like.

16.8399Edit=0.0729((28Edit)2-5Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Maximum Head Loss when screen is 50 percent clogged

Maximum Head Loss when screen is 50 percent clogged Solution

Follow our step by step solution on how to calculate Maximum Head Loss when screen is 50 percent clogged?

FIRST Step Consider the formula
hL=0.0729((2v)2-u2)
Next Step Substitute values of Variables
hL=0.0729((28m/s)2-5m/s2)
Next Step Prepare to Evaluate
hL=0.0729((28)2-52)
LAST Step Evaluate
hL=16.8399m

Maximum Head Loss when screen is 50 percent clogged Formula Elements

Variables
Head Loss
The Head Loss is a measure of the reduction in the total head (sum of elevation head, velocity head and pressure head) of the fluid as it moves through a fluid system.
Symbol: hL
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Velocity of Flow after Screening
The Velocity of Flow after Screening is the flow of water after the screening which depends upon the clear spacing area within the screen.
Symbol: v
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.
Velocity of Flow before Screening
The Velocity of Flow before Screening is the flow of water before screening which depends upon the cross-section area of the channel.
Symbol: u
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.

Other Formulas to find Head Loss

​Go Head Loss through Screen
hL=0.0729(v2-u2)
​Go Minimum Head Loss when screen is fully functional
hL=0.0729(v2-u2)

Other formulas in Screening category

​Go Velocity through Screen given Head Loss through Screen
v=(hL0.0729)+u2
​Go Velocity above Screen given Head Loss through Screen
u=v2-(hL0.0729)

How to Evaluate Maximum Head Loss when screen is 50 percent clogged?

Maximum Head Loss when screen is 50 percent clogged evaluator uses Head Loss = 0.0729*((2*Velocity of Flow after Screening)^2-Velocity of Flow before Screening^2) to evaluate the Head Loss, The Maximum Head Loss when screen is 50 percent clogged is defined as the Head Loss through Screen which is 50% clogged is a measure of the reduction in the total head of the fluid as it moves through a fluid system. Head Loss is denoted by hL symbol.

How to evaluate Maximum Head Loss when screen is 50 percent clogged using this online evaluator? To use this online evaluator for Maximum Head Loss when screen is 50 percent clogged, enter Velocity of Flow after Screening (v) & Velocity of Flow before Screening (u) and hit the calculate button.

FAQs on Maximum Head Loss when screen is 50 percent clogged

What is the formula to find Maximum Head Loss when screen is 50 percent clogged?
The formula of Maximum Head Loss when screen is 50 percent clogged is expressed as Head Loss = 0.0729*((2*Velocity of Flow after Screening)^2-Velocity of Flow before Screening^2). Here is an example- 16.8399 = 0.0729*((2*8)^2-5^2).
How to calculate Maximum Head Loss when screen is 50 percent clogged?
With Velocity of Flow after Screening (v) & Velocity of Flow before Screening (u) we can find Maximum Head Loss when screen is 50 percent clogged using the formula - Head Loss = 0.0729*((2*Velocity of Flow after Screening)^2-Velocity of Flow before Screening^2).
What are the other ways to Calculate Head Loss?
Here are the different ways to Calculate Head Loss-
  • Head Loss=0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2)OpenImg
  • Head Loss=0.0729*(Velocity of Flow after Screening^2-Velocity of Flow before Screening^2)OpenImg
Can the Maximum Head Loss when screen is 50 percent clogged be negative?
Yes, the Maximum Head Loss when screen is 50 percent clogged, measured in Length can be negative.
Which unit is used to measure Maximum Head Loss when screen is 50 percent clogged?
Maximum Head Loss when screen is 50 percent clogged is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Maximum Head Loss when screen is 50 percent clogged can be measured.
Copied!