Maximum Controlling Parameter for Angular Distribution Formula

Fx Copy
LaTeX Copy
Controlling Parameter for the Angular Distribution determines how the energy or intensity of a wave or signal is distributed across different angular directions within the model. Check FAQs
s=11.5(2πfpV10[g])-2.5
s - Controlling Parameter for the Angular Distribution?fp - Frequency at Spectral Peak?V10 - Wind Speed at Height of 10 m?[g] - Gravitational acceleration on Earth?π - Archimedes' constant?

Maximum Controlling Parameter for Angular Distribution Example

With values
With units
Only example

Here is how the Maximum Controlling Parameter for Angular Distribution equation looks like with Values.

Here is how the Maximum Controlling Parameter for Angular Distribution equation looks like with Units.

Here is how the Maximum Controlling Parameter for Angular Distribution equation looks like.

2.5E-5Edit=11.5(23.14160.0132Edit22Edit9.8066)-2.5
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Coastal and Ocean Engineering » fx Maximum Controlling Parameter for Angular Distribution

Maximum Controlling Parameter for Angular Distribution Solution

Follow our step by step solution on how to calculate Maximum Controlling Parameter for Angular Distribution?

FIRST Step Consider the formula
s=11.5(2πfpV10[g])-2.5
Next Step Substitute values of Variables
s=11.5(2π0.0132kHz22m/s[g])-2.5
Next Step Substitute values of Constants
s=11.5(23.14160.0132kHz22m/s9.8066m/s²)-2.5
Next Step Convert Units
s=11.5(23.141613.162Hz22m/s9.8066m/s²)-2.5
Next Step Prepare to Evaluate
s=11.5(23.141613.162229.8066)-2.5
Next Step Evaluate
s=2.45294855624336E-05
LAST Step Rounding Answer
s=2.5E-5

Maximum Controlling Parameter for Angular Distribution Formula Elements

Variables
Constants
Controlling Parameter for the Angular Distribution
Controlling Parameter for the Angular Distribution determines how the energy or intensity of a wave or signal is distributed across different angular directions within the model.
Symbol: s
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Frequency at Spectral Peak
Frequency at Spectral Peak is the number of occurrences of a repeating event per unit of time.
Symbol: fp
Measurement: FrequencyUnit: kHz
Note: Value can be positive or negative.
Wind Speed at Height of 10 m
Wind Speed at Height of 10 m refers to the average speed of the wind measured at a height of 10 meters above ground level.
Symbol: V10
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Gravitational acceleration on Earth
Gravitational acceleration on Earth means that the velocity of an object in free fall will increase by 9.8 m/s2 every second.
Symbol: [g]
Value: 9.80665 m/s²
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Parametric Spectrum Models category

​Go Phillip's Equilibrium Range of Spectrum for Fully Developed Sea in Deep Water
Eω=b[g]2ω-5
​Go JONSWAP Spectrum for Fetch-limited Seas
Ef=(α[g]2(2π)4f5)(exp(-1.25(ffp)-4)γ)exp(-((ffp)-1)22σ2)
​Go Frequency at Spectral Peak
fp=3.5([g]2FlV103)-0.33
​Go Fetch Length given Frequency at Spectral Peak
Fl=(V103)((fp3.5)-(10.33))[g]2

How to Evaluate Maximum Controlling Parameter for Angular Distribution?

Maximum Controlling Parameter for Angular Distribution evaluator uses Controlling Parameter for the Angular Distribution = 11.5*((2*pi*Frequency at Spectral Peak*Wind Speed at Height of 10 m)/[g])^-2.5 to evaluate the Controlling Parameter for the Angular Distribution, The Maximum Controlling Parameter for Angular Distribution formula refers to how the energy or intensity of a wave or signal is distributed across different angular directions within the model. Controlling Parameter for the Angular Distribution is denoted by s symbol.

How to evaluate Maximum Controlling Parameter for Angular Distribution using this online evaluator? To use this online evaluator for Maximum Controlling Parameter for Angular Distribution, enter Frequency at Spectral Peak (fp) & Wind Speed at Height of 10 m (V10) and hit the calculate button.

FAQs on Maximum Controlling Parameter for Angular Distribution

What is the formula to find Maximum Controlling Parameter for Angular Distribution?
The formula of Maximum Controlling Parameter for Angular Distribution is expressed as Controlling Parameter for the Angular Distribution = 11.5*((2*pi*Frequency at Spectral Peak*Wind Speed at Height of 10 m)/[g])^-2.5. Here is an example- 2.5E-5 = 11.5*((2*pi*13.162*22)/[g])^-2.5.
How to calculate Maximum Controlling Parameter for Angular Distribution?
With Frequency at Spectral Peak (fp) & Wind Speed at Height of 10 m (V10) we can find Maximum Controlling Parameter for Angular Distribution using the formula - Controlling Parameter for the Angular Distribution = 11.5*((2*pi*Frequency at Spectral Peak*Wind Speed at Height of 10 m)/[g])^-2.5. This formula also uses Gravitational acceleration on Earth, Archimedes' constant .
Copied!