Mass flux given mass flowrate Formula

Fx Copy
LaTeX Copy
Mass flux(g) is defined as the amount of mass transported per unit time across a unit area that is perpendicular to the direction of mass transport. Check FAQs
G=mNTPhc
G - Mass Flux(g)?m - Mass Flow Rate?N - Number of Tubes?TP - Distance between two Consequent Tubes?hc - Height of Crack?

Mass flux given mass flowrate Example

With values
With units
Only example

Here is how the Mass flux given mass flowrate equation looks like with Values.

Here is how the Mass flux given mass flowrate equation looks like with Units.

Here is how the Mass flux given mass flowrate equation looks like.

0.5051Edit=4Edit11Edit0.06Edit12000Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Mass flux given mass flowrate

Mass flux given mass flowrate Solution

Follow our step by step solution on how to calculate Mass flux given mass flowrate?

FIRST Step Consider the formula
G=mNTPhc
Next Step Substitute values of Variables
G=4kg/s110.06m12000mm
Next Step Convert Units
G=4kg/s110.06m12m
Next Step Prepare to Evaluate
G=4110.0612
Next Step Evaluate
G=0.505050505050505kg/s/m²
LAST Step Rounding Answer
G=0.5051kg/s/m²

Mass flux given mass flowrate Formula Elements

Variables
Mass Flux(g)
Mass flux(g) is defined as the amount of mass transported per unit time across a unit area that is perpendicular to the direction of mass transport.
Symbol: G
Measurement: Mass FluxUnit: kg/s/m²
Note: Value can be positive or negative.
Mass Flow Rate
Mass flow rate is the mass of a substance that passes per unit of time. Its unit is kilogram per second in SI units.
Symbol: m
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Number of Tubes
Number of tubes is the total count of the tubes.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Distance between two Consequent Tubes
Distance between two consequent tubes is the centre distance between the two tubes in a heat exchanger.
Symbol: TP
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Height of Crack
Height of Crack is the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Symbol: hc
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other formulas in Convection Coefficient category

​Go Height of tube tank given convection coefficient
hc=((ηAs)+AB)hoeπhiadi
​Go Inner diameter of tube given convection coefficient
di=((ηAs)+AB)hoehiaπhc
​Go Overall heat transfer coefficient given convection coefficient
Uoverall=hiahiehia+hie
​Go Surface area of fin given convection coefficient
As=(hiaπdihchoe)-ABη

How to Evaluate Mass flux given mass flowrate?

Mass flux given mass flowrate evaluator uses Mass Flux(g) = Mass Flow Rate/(Number of Tubes*Distance between two Consequent Tubes*Height of Crack) to evaluate the Mass Flux(g), The Mass flux given mass flowrate formula is defined as the contaminant mass moving across a unit area of porous media. Mass Flux(g) is denoted by G symbol.

How to evaluate Mass flux given mass flowrate using this online evaluator? To use this online evaluator for Mass flux given mass flowrate, enter Mass Flow Rate (m), Number of Tubes (N), Distance between two Consequent Tubes (TP) & Height of Crack (hc) and hit the calculate button.

FAQs on Mass flux given mass flowrate

What is the formula to find Mass flux given mass flowrate?
The formula of Mass flux given mass flowrate is expressed as Mass Flux(g) = Mass Flow Rate/(Number of Tubes*Distance between two Consequent Tubes*Height of Crack). Here is an example- 0.505051 = 4/(11*0.06*12).
How to calculate Mass flux given mass flowrate?
With Mass Flow Rate (m), Number of Tubes (N), Distance between two Consequent Tubes (TP) & Height of Crack (hc) we can find Mass flux given mass flowrate using the formula - Mass Flux(g) = Mass Flow Rate/(Number of Tubes*Distance between two Consequent Tubes*Height of Crack).
Can the Mass flux given mass flowrate be negative?
Yes, the Mass flux given mass flowrate, measured in Mass Flux can be negative.
Which unit is used to measure Mass flux given mass flowrate?
Mass flux given mass flowrate is usually measured using the Kilogram per Second per Square Meter[kg/s/m²] for Mass Flux. Kilogram per Hour per Square Meter[kg/s/m²], Kilogram per Hour per Square Foot[kg/s/m²], Pound per Hour per Square Foot[kg/s/m²] are the few other units in which Mass flux given mass flowrate can be measured.
Copied!