Mass Flowrate of Fluid in Storage type Heat Exchanger Formula

Fx Copy
LaTeX Copy
Mass flowrate is the mass moved in unit amount of time. Check FAQs
m=hConvSAxcE
m - Mass Flowrate?hConv - Convective Heat Transfer Coefficient?SA - Surface Area?x - Distance from Point to YY Axis?c - Specific heat of fluid?E - Location factor?

Mass Flowrate of Fluid in Storage type Heat Exchanger Example

With values
With units
Only example

Here is how the Mass Flowrate of Fluid in Storage type Heat Exchanger equation looks like with Values.

Here is how the Mass Flowrate of Fluid in Storage type Heat Exchanger equation looks like with Units.

Here is how the Mass Flowrate of Fluid in Storage type Heat Exchanger equation looks like.

0.135Edit=0.5Edit18Edit1.5Edit10Edit10Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Mass Flowrate of Fluid in Storage type Heat Exchanger

Mass Flowrate of Fluid in Storage type Heat Exchanger Solution

Follow our step by step solution on how to calculate Mass Flowrate of Fluid in Storage type Heat Exchanger?

FIRST Step Consider the formula
m=hConvSAxcE
Next Step Substitute values of Variables
m=0.5W/m²*K181.5m10J/(kg*K)10
Next Step Prepare to Evaluate
m=0.5181.51010
LAST Step Evaluate
m=0.135kg/s

Mass Flowrate of Fluid in Storage type Heat Exchanger Formula Elements

Variables
Mass Flowrate
Mass flowrate is the mass moved in unit amount of time.
Symbol: m
Measurement: Mass Flow RateUnit: kg/s
Note: Value can be positive or negative.
Convective Heat Transfer Coefficient
Convective Heat Transfer Coefficient is the heat transfer due to convection.
Symbol: hConv
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value can be positive or negative.
Surface Area
The Surface Area of a three-dimensional shape is the sum of all of the surface areas of each of the sides.
Symbol: SA
Measurement: AreaUnit:
Note: Value can be positive or negative.
Distance from Point to YY Axis
Distance from Point to YY Axis is the distance from the point to the YY axis where stress is to be computed.
Symbol: x
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Specific heat of fluid
Specific heat of fluid is the amount f heat required to increase the temperature of the fluid by one degree.
Symbol: c
Measurement: Specific Heat CapacityUnit: J/(kg*K)
Note: Value can be positive or negative.
Location factor
Location factor the sum of all factors that an enterprise considers when choosing a location, for setting up a heat exchanger.
Symbol: E
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Physical Parameters of Heat Exchanger category

​Go Correction factor in heat exchanger
f=QUAΔTm
​Go Area of heat exchanger
A=QUΔTmf
​Go Mass flow rate of hot fluid
mh=(ϵCminch)(1T1-t2T1-t1)
​Go Mass flow rate of cold fluid
mc=(ϵCmincc)(1t2-t1T1-t1)

How to Evaluate Mass Flowrate of Fluid in Storage type Heat Exchanger?

Mass Flowrate of Fluid in Storage type Heat Exchanger evaluator uses Mass Flowrate = (Convective Heat Transfer Coefficient*Surface Area*Distance from Point to YY Axis)/(Specific heat of fluid*Location factor) to evaluate the Mass Flowrate, The Mass flowrate of fluid in storage type heat exchanger formula is defined as the amount of fluid transferred or moved within the area in unit time. Mass Flowrate is denoted by m symbol.

How to evaluate Mass Flowrate of Fluid in Storage type Heat Exchanger using this online evaluator? To use this online evaluator for Mass Flowrate of Fluid in Storage type Heat Exchanger, enter Convective Heat Transfer Coefficient (hConv), Surface Area (SA), Distance from Point to YY Axis (x), Specific heat of fluid (c) & Location factor (E) and hit the calculate button.

FAQs on Mass Flowrate of Fluid in Storage type Heat Exchanger

What is the formula to find Mass Flowrate of Fluid in Storage type Heat Exchanger?
The formula of Mass Flowrate of Fluid in Storage type Heat Exchanger is expressed as Mass Flowrate = (Convective Heat Transfer Coefficient*Surface Area*Distance from Point to YY Axis)/(Specific heat of fluid*Location factor). Here is an example- 0.135 = (0.5*18*1.5)/(10*10).
How to calculate Mass Flowrate of Fluid in Storage type Heat Exchanger?
With Convective Heat Transfer Coefficient (hConv), Surface Area (SA), Distance from Point to YY Axis (x), Specific heat of fluid (c) & Location factor (E) we can find Mass Flowrate of Fluid in Storage type Heat Exchanger using the formula - Mass Flowrate = (Convective Heat Transfer Coefficient*Surface Area*Distance from Point to YY Axis)/(Specific heat of fluid*Location factor).
Can the Mass Flowrate of Fluid in Storage type Heat Exchanger be negative?
Yes, the Mass Flowrate of Fluid in Storage type Heat Exchanger, measured in Mass Flow Rate can be negative.
Which unit is used to measure Mass Flowrate of Fluid in Storage type Heat Exchanger?
Mass Flowrate of Fluid in Storage type Heat Exchanger is usually measured using the Kilogram per Second[kg/s] for Mass Flow Rate. Gram per Second[kg/s], Gram per Hour[kg/s], Milligram per Minute[kg/s] are the few other units in which Mass Flowrate of Fluid in Storage type Heat Exchanger can be measured.
Copied!