Fx Copy
LaTeX Copy
The Manometric Head of Centrifugal Pump is the head against which the centrifugal pump has to work. Check FAQs
Hm=(hs+hd)+(hfs+hfd)+Vd22[g]
Hm - Manometric Head of Centrifugal Pump?hs - Suction Head of Centrifugal Pump?hd - Delivery Head of Pump?hfs - Friction Head Loss in Pump Suction Pipe?hfd - Friction Head Loss in Pump Delivery Pipe?Vd - Velocity in Delivery Pipe?[g] - Gravitational acceleration on Earth?

Manometric head given static head, friction losses in suction and delivery pipes Example

With values
With units
Only example

Here is how the Manometric head given static head, friction losses in suction and delivery pipes equation looks like with Values.

Here is how the Manometric head given static head, friction losses in suction and delivery pipes equation looks like with Units.

Here is how the Manometric head given static head, friction losses in suction and delivery pipes equation looks like.

25.1946Edit=(7.3Edit+13.7Edit)+(1.2Edit+1.6Edit)+5.23Edit229.8066
You are here -

Manometric head given static head, friction losses in suction and delivery pipes Solution

Follow our step by step solution on how to calculate Manometric head given static head, friction losses in suction and delivery pipes?

FIRST Step Consider the formula
Hm=(hs+hd)+(hfs+hfd)+Vd22[g]
Next Step Substitute values of Variables
Hm=(7.3m+13.7m)+(1.2m+1.6m)+5.23m/s22[g]
Next Step Substitute values of Constants
Hm=(7.3m+13.7m)+(1.2m+1.6m)+5.23m/s229.8066m/s²
Next Step Prepare to Evaluate
Hm=(7.3+13.7)+(1.2+1.6)+5.23229.8066
Next Step Evaluate
Hm=25.1946097800982m
LAST Step Rounding Answer
Hm=25.1946m

Manometric head given static head, friction losses in suction and delivery pipes Formula Elements

Variables
Constants
Manometric Head of Centrifugal Pump
The Manometric Head of Centrifugal Pump is the head against which the centrifugal pump has to work.
Symbol: Hm
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Suction Head of Centrifugal Pump
Suction head of centrifugal pump is the vertical height of the center line of the pump shaft above the liquid surface in the sump from which the liquid is being raised.
Symbol: hs
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Delivery Head of Pump
Delivery head of pump is the vertical height of the liquid surface in the tank/reservoir to which the liquid is delivered above the centre line of the pump shaft.
Symbol: hd
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Friction Head Loss in Pump Suction Pipe
Friction head loss in pump suction pipe is a measure of the reduction in the total head of the fluid due to friction as it moves through the delivery pipe.
Symbol: hfs
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Friction Head Loss in Pump Delivery Pipe
Friction head loss in pump delivery pipe is a measure of the reduction in the total head of the fluid due to friction as it moves through the delivery pipe.
Symbol: hfd
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Velocity in Delivery Pipe
Velocity in Delivery Pipe is the velocity of the liquid flowing through the delivery pipe.
Symbol: Vd
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Gravitational acceleration on Earth
Gravitational acceleration on Earth means that the velocity of an object in free fall will increase by 9.8 m/s2 every second.
Symbol: [g]
Value: 9.80665 m/s²

Other Formulas to find Manometric Head of Centrifugal Pump

​Go Manometric Head using Static Head and Losses in Pipes
Hm=Hst+hfd+hfs+Vd22[g]
​Go Manometric head given head imparted by impeller and loss of head in pump
Hm=(Vw2u2[g])-(hLi+hLc)
​Go Manometric Head using Total Head at Outlet and Inlet of Pump
Hm=((P2w)+(Vd22[g])+Z2)-((P1w)+(Vs22[g])+Z1)
​Go Manometric head given head imparted by impeller if loss of head in pump is zero
Hm=Vw2u2[g]

Other formulas in Manometer Parameter category

​Go Manometric efficiency
ηm=HmHI
​Go Manometric Efficiency using Velocities
ηm=[g]HmVw2u2
​Go Overall Efficiency using Manometric, Volumetric and Mechanical Efficiencies
ηo=ηmηvolηcp

How to Evaluate Manometric head given static head, friction losses in suction and delivery pipes?

Manometric head given static head, friction losses in suction and delivery pipes evaluator uses Manometric Head of Centrifugal Pump = (Suction Head of Centrifugal Pump+Delivery Head of Pump)+(Friction Head Loss in Pump Suction Pipe+Friction Head Loss in Pump Delivery Pipe)+(Velocity in Delivery Pipe^2)/(2*[g]) to evaluate the Manometric Head of Centrifugal Pump, Manometric head given static head, friction losses in suction and delivery pipes formula is defined as the total head developed by a centrifugal pump, considering the static head, friction losses in both suction and delivery pipes, and the velocity head of the fluid at the delivery point. Manometric Head of Centrifugal Pump is denoted by Hm symbol.

How to evaluate Manometric head given static head, friction losses in suction and delivery pipes using this online evaluator? To use this online evaluator for Manometric head given static head, friction losses in suction and delivery pipes, enter Suction Head of Centrifugal Pump (hs), Delivery Head of Pump (hd), Friction Head Loss in Pump Suction Pipe (hfs), Friction Head Loss in Pump Delivery Pipe (hfd) & Velocity in Delivery Pipe (Vd) and hit the calculate button.

FAQs on Manometric head given static head, friction losses in suction and delivery pipes

What is the formula to find Manometric head given static head, friction losses in suction and delivery pipes?
The formula of Manometric head given static head, friction losses in suction and delivery pipes is expressed as Manometric Head of Centrifugal Pump = (Suction Head of Centrifugal Pump+Delivery Head of Pump)+(Friction Head Loss in Pump Suction Pipe+Friction Head Loss in Pump Delivery Pipe)+(Velocity in Delivery Pipe^2)/(2*[g]). Here is an example- 25.19461 = (7.3+13.7)+(1.2+1.6)+(5.23^2)/(2*[g]).
How to calculate Manometric head given static head, friction losses in suction and delivery pipes?
With Suction Head of Centrifugal Pump (hs), Delivery Head of Pump (hd), Friction Head Loss in Pump Suction Pipe (hfs), Friction Head Loss in Pump Delivery Pipe (hfd) & Velocity in Delivery Pipe (Vd) we can find Manometric head given static head, friction losses in suction and delivery pipes using the formula - Manometric Head of Centrifugal Pump = (Suction Head of Centrifugal Pump+Delivery Head of Pump)+(Friction Head Loss in Pump Suction Pipe+Friction Head Loss in Pump Delivery Pipe)+(Velocity in Delivery Pipe^2)/(2*[g]). This formula also uses Gravitational acceleration on Earth constant(s).
What are the other ways to Calculate Manometric Head of Centrifugal Pump?
Here are the different ways to Calculate Manometric Head of Centrifugal Pump-
  • Manometric Head of Centrifugal Pump=Static Head of Centrifugal Pump+Friction Head Loss in Pump Delivery Pipe+Friction Head Loss in Pump Suction Pipe+(Velocity in Delivery Pipe^2)/(2*[g])OpenImg
  • Manometric Head of Centrifugal Pump=(Velocity of Whirl at Outlet*Tangential Velocity of Impeller at Outlet/[g])-(Head Loss in Pump Impeller+Head Loss in Pump Casing)OpenImg
  • Manometric Head of Centrifugal Pump=((Pressure at Pump Outlet/Specific Weight of Fluid in Pump)+((Velocity in Delivery Pipe^2)/(2*[g]))+Datum Head at Pump Outlet)-((Pressure at Pump Inlet/Specific Weight of Fluid in Pump)+((Velocity in Suction Pipe^2)/(2*[g]))+Datum Head at Pump Inlet)OpenImg
Can the Manometric head given static head, friction losses in suction and delivery pipes be negative?
No, the Manometric head given static head, friction losses in suction and delivery pipes, measured in Length cannot be negative.
Which unit is used to measure Manometric head given static head, friction losses in suction and delivery pipes?
Manometric head given static head, friction losses in suction and delivery pipes is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Manometric head given static head, friction losses in suction and delivery pipes can be measured.
Copied!