Fx Copy
LaTeX Copy
The Manometric Head of Centrifugal Pump is the head against which the centrifugal pump has to work. Check FAQs
Hm=(D2ω84.6Ku)2
Hm - Manometric Head of Centrifugal Pump?D2 - Diameter of Centrifugal Pump Impeller at Outlet?ω - Angular Velocity?Ku - Speed Ratio Centrifugal Pump?

Manometric head given outlet impeller diameter, impeller speed and speed ratio Example

With values
With units
Only example

Here is how the Manometric head given outlet impeller diameter, impeller speed and speed ratio equation looks like with Values.

Here is how the Manometric head given outlet impeller diameter, impeller speed and speed ratio equation looks like with Units.

Here is how the Manometric head given outlet impeller diameter, impeller speed and speed ratio equation looks like.

44.3329Edit=(0.28Edit179.07Edit84.60.85Edit)2
You are here -

Manometric head given outlet impeller diameter, impeller speed and speed ratio Solution

Follow our step by step solution on how to calculate Manometric head given outlet impeller diameter, impeller speed and speed ratio?

FIRST Step Consider the formula
Hm=(D2ω84.6Ku)2
Next Step Substitute values of Variables
Hm=(0.28m179.07rad/s84.60.85)2
Next Step Convert Units
Hm=(0.28m1709.9925rev/min84.60.85)2
Next Step Prepare to Evaluate
Hm=(0.281709.992584.60.85)2
Next Step Evaluate
Hm=44.3328770577448m
LAST Step Rounding Answer
Hm=44.3329m

Manometric head given outlet impeller diameter, impeller speed and speed ratio Formula Elements

Variables
Manometric Head of Centrifugal Pump
The Manometric Head of Centrifugal Pump is the head against which the centrifugal pump has to work.
Symbol: Hm
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Diameter of Centrifugal Pump Impeller at Outlet
Diameter of centrifugal pump impeller at outlet is the diameter of the impeller at the outlet of the centrifugal pump.
Symbol: D2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Angular Velocity
The Angular Velocity of Centrifugal Pump refers to how fast the pump impeller rotates.
Symbol: ω
Measurement: Angular VelocityUnit: rad/s
Note: Value should be greater than 0.
Speed Ratio Centrifugal Pump
Speed ratio centrifugal pump is the ratio of the peripheral speed of impeller at exit to the theoretical velocity of the jet corresponding to manometric head.
Symbol: Ku
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Manometric Head of Centrifugal Pump

​Go Manometric Head using Static Head and Losses in Pipes
Hm=Hst+hfd+hfs+Vd22[g]
​Go Manometric head given head imparted by impeller and loss of head in pump
Hm=(Vw2u2[g])-(hLi+hLc)
​Go Manometric Head using Total Head at Outlet and Inlet of Pump
Hm=((P2w)+(Vd22[g])+Z2)-((P1w)+(Vs22[g])+Z1)
​Go Manometric head given static head, friction losses in suction and delivery pipes
Hm=(hs+hd)+(hfs+hfd)+Vd22[g]

Other formulas in Manometer Parameter category

​Go Manometric efficiency
ηm=HmHI
​Go Manometric Efficiency using Velocities
ηm=[g]HmVw2u2
​Go Overall Efficiency using Manometric, Volumetric and Mechanical Efficiencies
ηo=ηmηvolηcp

How to Evaluate Manometric head given outlet impeller diameter, impeller speed and speed ratio?

Manometric head given outlet impeller diameter, impeller speed and speed ratio evaluator uses Manometric Head of Centrifugal Pump = ((Diameter of Centrifugal Pump Impeller at Outlet*Angular Velocity)/(84.6*Speed Ratio Centrifugal Pump))^2 to evaluate the Manometric Head of Centrifugal Pump, Manometric head given outlet impeller diameter, impeller speed and speed ratio formula is defined as a measure of the total head or pressure developed by a centrifugal pump, which is a critical parameter in determining the pump's performance and efficiency in various industrial applications. Manometric Head of Centrifugal Pump is denoted by Hm symbol.

How to evaluate Manometric head given outlet impeller diameter, impeller speed and speed ratio using this online evaluator? To use this online evaluator for Manometric head given outlet impeller diameter, impeller speed and speed ratio, enter Diameter of Centrifugal Pump Impeller at Outlet (D2), Angular Velocity (ω) & Speed Ratio Centrifugal Pump (Ku) and hit the calculate button.

FAQs on Manometric head given outlet impeller diameter, impeller speed and speed ratio

What is the formula to find Manometric head given outlet impeller diameter, impeller speed and speed ratio?
The formula of Manometric head given outlet impeller diameter, impeller speed and speed ratio is expressed as Manometric Head of Centrifugal Pump = ((Diameter of Centrifugal Pump Impeller at Outlet*Angular Velocity)/(84.6*Speed Ratio Centrifugal Pump))^2. Here is an example- 44.33288 = ((0.28*179.07)/(84.6*0.85))^2.
How to calculate Manometric head given outlet impeller diameter, impeller speed and speed ratio?
With Diameter of Centrifugal Pump Impeller at Outlet (D2), Angular Velocity (ω) & Speed Ratio Centrifugal Pump (Ku) we can find Manometric head given outlet impeller diameter, impeller speed and speed ratio using the formula - Manometric Head of Centrifugal Pump = ((Diameter of Centrifugal Pump Impeller at Outlet*Angular Velocity)/(84.6*Speed Ratio Centrifugal Pump))^2.
What are the other ways to Calculate Manometric Head of Centrifugal Pump?
Here are the different ways to Calculate Manometric Head of Centrifugal Pump-
  • Manometric Head of Centrifugal Pump=Static Head of Centrifugal Pump+Friction Head Loss in Pump Delivery Pipe+Friction Head Loss in Pump Suction Pipe+(Velocity in Delivery Pipe^2)/(2*[g])OpenImg
  • Manometric Head of Centrifugal Pump=(Velocity of Whirl at Outlet*Tangential Velocity of Impeller at Outlet/[g])-(Head Loss in Pump Impeller+Head Loss in Pump Casing)OpenImg
  • Manometric Head of Centrifugal Pump=((Pressure at Pump Outlet/Specific Weight of Fluid in Pump)+((Velocity in Delivery Pipe^2)/(2*[g]))+Datum Head at Pump Outlet)-((Pressure at Pump Inlet/Specific Weight of Fluid in Pump)+((Velocity in Suction Pipe^2)/(2*[g]))+Datum Head at Pump Inlet)OpenImg
Can the Manometric head given outlet impeller diameter, impeller speed and speed ratio be negative?
No, the Manometric head given outlet impeller diameter, impeller speed and speed ratio, measured in Length cannot be negative.
Which unit is used to measure Manometric head given outlet impeller diameter, impeller speed and speed ratio?
Manometric head given outlet impeller diameter, impeller speed and speed ratio is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Manometric head given outlet impeller diameter, impeller speed and speed ratio can be measured.
Copied!