Make up Liquid Temperature given Energy Discharge Rate Formula

Fx Copy
LaTeX Copy
Temperature of Makeup Liquid is the temperature of the liquid used to top up the thermal storage system to maintain its thermal energy capacity. Check FAQs
Ti=Tl-(qlmlCpk)
Ti - Temperature of Makeup Liquid?Tl - Temperature of Liquid in Tank?ql - Energy Discharge Rate to Load?ml - Mass Flow Rate to Load?Cpk - Specific Heat Capacity at Constant Pressure Per K?

Make up Liquid Temperature given Energy Discharge Rate Example

With values
With units
Only example

Here is how the Make up Liquid Temperature given Energy Discharge Rate equation looks like with Values.

Here is how the Make up Liquid Temperature given Energy Discharge Rate equation looks like with Units.

Here is how the Make up Liquid Temperature given Energy Discharge Rate equation looks like.

300Edit=300.0012Edit-(15250Edit2.5Edit5000Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Solar Energy Systems » fx Make up Liquid Temperature given Energy Discharge Rate

Make up Liquid Temperature given Energy Discharge Rate Solution

Follow our step by step solution on how to calculate Make up Liquid Temperature given Energy Discharge Rate?

FIRST Step Consider the formula
Ti=Tl-(qlmlCpk)
Next Step Substitute values of Variables
Ti=300.0012K-(15250W2.5kg/s5000kJ/kg*K)
Next Step Convert Units
Ti=300.0012K-(15250W2.5kg/s5E+6J/(kg*K))
Next Step Prepare to Evaluate
Ti=300.0012-(152502.55E+6)
Next Step Evaluate
Ti=299.99998K
LAST Step Rounding Answer
Ti=300K

Make up Liquid Temperature given Energy Discharge Rate Formula Elements

Variables
Temperature of Makeup Liquid
Temperature of Makeup Liquid is the temperature of the liquid used to top up the thermal storage system to maintain its thermal energy capacity.
Symbol: Ti
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Temperature of Liquid in Tank
Temperature of Liquid in Tank is the temperature of the liquid stored in a thermal energy storage tank, used to store thermal energy.
Symbol: Tl
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Energy Discharge Rate to Load
Energy Discharge Rate to Load is the rate at which thermal energy is released from the storage system to meet the load requirements.
Symbol: ql
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Mass Flow Rate to Load
Mass Flow Rate to Load is the rate at which thermal energy is transferred to the load from the thermal storage system during discharge.
Symbol: ml
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Specific Heat Capacity at Constant Pressure Per K
Specific Heat Capacity at Constant Pressure per K is the amount of heat energy required to raise the temperature of a unit mass of a substance by one degree Kelvin.
Symbol: Cpk
Measurement: Specific Heat CapacityUnit: kJ/kg*K
Note: Value should be greater than 0.

Other formulas in Thermal Energy Storage category

​Go Useful heat gain in liquid storage tank
qu=mCp molar(Tfo-Tl)
​Go Liquid Temperature given Useful Heat Gain
Tl=Tfo-(qumCp molar)
​Go Energy Discharge Rate to Load
ql=mlCp molar(Tl-Ti)
​Go Liquid Temperature given Energy Discharge Rate
Tl=(qlmlCpk)+Ti

How to Evaluate Make up Liquid Temperature given Energy Discharge Rate?

Make up Liquid Temperature given Energy Discharge Rate evaluator uses Temperature of Makeup Liquid = Temperature of Liquid in Tank-(Energy Discharge Rate to Load/(Mass Flow Rate to Load*Specific Heat Capacity at Constant Pressure Per K)) to evaluate the Temperature of Makeup Liquid, Make up Liquid Temperature given Energy Discharge Rate formula is defined as a thermal property that characterizes the temperature of a liquid in a thermal energy storage system, specifically in solar energy applications, where it plays a crucial role in determining the system's overall efficiency and performance. Temperature of Makeup Liquid is denoted by Ti symbol.

How to evaluate Make up Liquid Temperature given Energy Discharge Rate using this online evaluator? To use this online evaluator for Make up Liquid Temperature given Energy Discharge Rate, enter Temperature of Liquid in Tank (Tl), Energy Discharge Rate to Load (ql), Mass Flow Rate to Load (ml) & Specific Heat Capacity at Constant Pressure Per K (Cpk) and hit the calculate button.

FAQs on Make up Liquid Temperature given Energy Discharge Rate

What is the formula to find Make up Liquid Temperature given Energy Discharge Rate?
The formula of Make up Liquid Temperature given Energy Discharge Rate is expressed as Temperature of Makeup Liquid = Temperature of Liquid in Tank-(Energy Discharge Rate to Load/(Mass Flow Rate to Load*Specific Heat Capacity at Constant Pressure Per K)). Here is an example- 349.9988 = 300.0012-(15250/(2.5*5000000)).
How to calculate Make up Liquid Temperature given Energy Discharge Rate?
With Temperature of Liquid in Tank (Tl), Energy Discharge Rate to Load (ql), Mass Flow Rate to Load (ml) & Specific Heat Capacity at Constant Pressure Per K (Cpk) we can find Make up Liquid Temperature given Energy Discharge Rate using the formula - Temperature of Makeup Liquid = Temperature of Liquid in Tank-(Energy Discharge Rate to Load/(Mass Flow Rate to Load*Specific Heat Capacity at Constant Pressure Per K)).
Can the Make up Liquid Temperature given Energy Discharge Rate be negative?
No, the Make up Liquid Temperature given Energy Discharge Rate, measured in Temperature cannot be negative.
Which unit is used to measure Make up Liquid Temperature given Energy Discharge Rate?
Make up Liquid Temperature given Energy Discharge Rate is usually measured using the Kelvin[K] for Temperature. Celsius[K], Fahrenheit[K], Rankine[K] are the few other units in which Make up Liquid Temperature given Energy Discharge Rate can be measured.
Copied!