Fx Copy
LaTeX Copy
Constant of Machine construction is a constant term which is calculated separately to a make calculation less complex. Check FAQs
Kf=VaΦωsIa
Kf - Constant of Machine Construction?Va - Armature Voltage?Φ - Magnetic Flux?ωs - Angular Speed?Ia - Armature Current?

Machine Construction Constant of Series DC Motor using Armature Induced Voltage Example

With values
With units
Only example

Here is how the Machine Construction Constant of Series DC Motor using Armature Induced Voltage equation looks like with Values.

Here is how the Machine Construction Constant of Series DC Motor using Armature Induced Voltage equation looks like with Units.

Here is how the Machine Construction Constant of Series DC Motor using Armature Induced Voltage equation looks like.

4.2373Edit=180Edit1.187Edit49.43Edit0.724Edit
You are here -

Machine Construction Constant of Series DC Motor using Armature Induced Voltage Solution

Follow our step by step solution on how to calculate Machine Construction Constant of Series DC Motor using Armature Induced Voltage?

FIRST Step Consider the formula
Kf=VaΦωsIa
Next Step Substitute values of Variables
Kf=180V1.187Wb49.43rad/s0.724A
Next Step Prepare to Evaluate
Kf=1801.18749.430.724
Next Step Evaluate
Kf=4.23733313830552
LAST Step Rounding Answer
Kf=4.2373

Machine Construction Constant of Series DC Motor using Armature Induced Voltage Formula Elements

Variables
Constant of Machine Construction
Constant of Machine construction is a constant term which is calculated separately to a make calculation less complex.
Symbol: Kf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Armature Voltage
The Armature Voltage is described by making use of Faraday’s law of induction. Induced voltage of a closed circuit is described as rate of change of magnetic flux through that closed circuit.
Symbol: Va
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Magnetic Flux
Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor.
Symbol: Φ
Measurement: Magnetic FluxUnit: Wb
Note: Value should be greater than 0.
Angular Speed
The angular speed refers to the rate at which the rotor (the rotating part of the motor) rotates. It is typically measured in terms of rotations per minute (RPM) or radians per second (rad/s).
Symbol: ωs
Measurement: Angular VelocityUnit: rad/s
Note: Value should be greater than 0.
Armature Current
The armature current plays a crucial role in determining the performance and operation of a DC motor. It affects the motor's torque production, speed, and efficiency.
Symbol: Ia
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Constant of Machine Construction

​Go Machine Construction Constant of Series DC Motor using Speed
Kf=Vs-Ia(Ra+Rsf)ΦN

Other formulas in Mechanical Specifications category

​Go Magnetic Flux of Series DC Motor given Speed
Φ=Vs-Ia(Ra+Rsf)KfN

How to Evaluate Machine Construction Constant of Series DC Motor using Armature Induced Voltage?

Machine Construction Constant of Series DC Motor using Armature Induced Voltage evaluator uses Constant of Machine Construction = Armature Voltage/(Magnetic Flux*Angular Speed*Armature Current) to evaluate the Constant of Machine Construction, The Machine Construction Constant of Series DC Motor using Armature Induced Voltage formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine. Constant of Machine Construction is denoted by Kf symbol.

How to evaluate Machine Construction Constant of Series DC Motor using Armature Induced Voltage using this online evaluator? To use this online evaluator for Machine Construction Constant of Series DC Motor using Armature Induced Voltage, enter Armature Voltage (Va), Magnetic Flux (Φ), Angular Speed s) & Armature Current (Ia) and hit the calculate button.

FAQs on Machine Construction Constant of Series DC Motor using Armature Induced Voltage

What is the formula to find Machine Construction Constant of Series DC Motor using Armature Induced Voltage?
The formula of Machine Construction Constant of Series DC Motor using Armature Induced Voltage is expressed as Constant of Machine Construction = Armature Voltage/(Magnetic Flux*Angular Speed*Armature Current). Here is an example- 2.524423 = 180/(1.187*49.43*0.724).
How to calculate Machine Construction Constant of Series DC Motor using Armature Induced Voltage?
With Armature Voltage (Va), Magnetic Flux (Φ), Angular Speed s) & Armature Current (Ia) we can find Machine Construction Constant of Series DC Motor using Armature Induced Voltage using the formula - Constant of Machine Construction = Armature Voltage/(Magnetic Flux*Angular Speed*Armature Current).
What are the other ways to Calculate Constant of Machine Construction?
Here are the different ways to Calculate Constant of Machine Construction-
  • Constant of Machine Construction=(Supply Voltage-Armature Current*(Armature Resistance+Series Field Resistance))/(Magnetic Flux*Motor Speed)OpenImg
Copied!