Lower Trigger Point Voltage in Square Wave Generator Formula

Fx Copy
LaTeX Copy
Lower Trigger Voltage refers to a specific voltage level in a Schmitt trigger circuit. Check FAQs
Vlt=VoutR3R2+R3
Vlt - Lower Trigger Voltage?Vout - Output Voltage?R3 - Resistance 3?R2 - Resistance 2?

Lower Trigger Point Voltage in Square Wave Generator Example

With values
With units
Only example

Here is how the Lower Trigger Point Voltage in Square Wave Generator equation looks like with Values.

Here is how the Lower Trigger Point Voltage in Square Wave Generator equation looks like with Units.

Here is how the Lower Trigger Point Voltage in Square Wave Generator equation looks like.

1.1571Edit=1.8Edit0.9Edit0.5Edit+0.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Signal Generator and Analyzer » fx Lower Trigger Point Voltage in Square Wave Generator

Lower Trigger Point Voltage in Square Wave Generator Solution

Follow our step by step solution on how to calculate Lower Trigger Point Voltage in Square Wave Generator?

FIRST Step Consider the formula
Vlt=VoutR3R2+R3
Next Step Substitute values of Variables
Vlt=1.8V0.9Ω0.5Ω+0.9Ω
Next Step Prepare to Evaluate
Vlt=1.80.90.5+0.9
Next Step Evaluate
Vlt=1.15714285714286V
LAST Step Rounding Answer
Vlt=1.1571V

Lower Trigger Point Voltage in Square Wave Generator Formula Elements

Variables
Lower Trigger Voltage
Lower Trigger Voltage refers to a specific voltage level in a Schmitt trigger circuit.
Symbol: Vlt
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Output Voltage
Output Voltage is electrical voltage produced by the device after it has processed an input signal.
Symbol: Vout
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Resistance 3
Resistance 3 is the value of resistor 3 of the oscillator which resist the flow of current.
Symbol: R3
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Resistance 2
Resistance 2 is the value of resistor 2 of the oscillator.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Signal Converter category

​Go Output Voltage of Triangle to Sine Converter without Diode 1 and Diode 2
Vout=VinR2R1+R2
​Go Output Voltage of Triangle to Sine Converter with Diode 1
Vout=Vin(R2R3(R1R2)+(R1R3)+(R2R3))
​Go Output Voltage of Triangle to Sine Converter with Diode 2
Vout=Vin(R2R4(R1R2)+(R1R4)+(R2R4))
​Go Upper Trigger Point Voltage in Triangle to Square Converter
Vut=Vout(R3R2+R3)

How to Evaluate Lower Trigger Point Voltage in Square Wave Generator?

Lower Trigger Point Voltage in Square Wave Generator evaluator uses Lower Trigger Voltage = Output Voltage*Resistance 3/(Resistance 2+Resistance 3) to evaluate the Lower Trigger Voltage, The Lower Trigger Point Voltage in Square Wave Generator formula is defined as the specific voltage level at which the output switches from high to low, initiating the falling edge of the square wave. Lower Trigger Voltage is denoted by Vlt symbol.

How to evaluate Lower Trigger Point Voltage in Square Wave Generator using this online evaluator? To use this online evaluator for Lower Trigger Point Voltage in Square Wave Generator, enter Output Voltage (Vout), Resistance 3 (R3) & Resistance 2 (R2) and hit the calculate button.

FAQs on Lower Trigger Point Voltage in Square Wave Generator

What is the formula to find Lower Trigger Point Voltage in Square Wave Generator?
The formula of Lower Trigger Point Voltage in Square Wave Generator is expressed as Lower Trigger Voltage = Output Voltage*Resistance 3/(Resistance 2+Resistance 3). Here is an example- 1.157143 = 1.8*0.9/(0.5+0.9).
How to calculate Lower Trigger Point Voltage in Square Wave Generator?
With Output Voltage (Vout), Resistance 3 (R3) & Resistance 2 (R2) we can find Lower Trigger Point Voltage in Square Wave Generator using the formula - Lower Trigger Voltage = Output Voltage*Resistance 3/(Resistance 2+Resistance 3).
Can the Lower Trigger Point Voltage in Square Wave Generator be negative?
No, the Lower Trigger Point Voltage in Square Wave Generator, measured in Electric Potential cannot be negative.
Which unit is used to measure Lower Trigger Point Voltage in Square Wave Generator?
Lower Trigger Point Voltage in Square Wave Generator is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Lower Trigger Point Voltage in Square Wave Generator can be measured.
Copied!