Load Voltage of Full Wave Three Phase Uncontrolled Rectifier Formula

Fx Copy
LaTeX Copy
AC Voltage uncontrolled rectifier is also known as the DC output voltage. It is the voltage that is available to the load circuit. Check FAQs
Vac=2nVmaxπ
Vac - AC Voltage?n - Winding Ratio?Vmax - Peak Input Voltage?π - Archimedes' constant?

Load Voltage of Full Wave Three Phase Uncontrolled Rectifier Example

With values
With units
Only example

Here is how the Load Voltage of Full Wave Three Phase Uncontrolled Rectifier equation looks like with Values.

Here is how the Load Voltage of Full Wave Three Phase Uncontrolled Rectifier equation looks like with Units.

Here is how the Load Voltage of Full Wave Three Phase Uncontrolled Rectifier equation looks like.

2100.8452Edit=215Edit220Edit3.1416
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Load Voltage of Full Wave Three Phase Uncontrolled Rectifier

Load Voltage of Full Wave Three Phase Uncontrolled Rectifier Solution

Follow our step by step solution on how to calculate Load Voltage of Full Wave Three Phase Uncontrolled Rectifier?

FIRST Step Consider the formula
Vac=2nVmaxπ
Next Step Substitute values of Variables
Vac=215220Vπ
Next Step Substitute values of Constants
Vac=215220V3.1416
Next Step Prepare to Evaluate
Vac=2152203.1416
Next Step Evaluate
Vac=2100.84524881302V
LAST Step Rounding Answer
Vac=2100.8452V

Load Voltage of Full Wave Three Phase Uncontrolled Rectifier Formula Elements

Variables
Constants
AC Voltage
AC Voltage uncontrolled rectifier is also known as the DC output voltage. It is the voltage that is available to the load circuit.
Symbol: Vac
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Winding Ratio
Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peak Input Voltage
Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Symbol: Vmax
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Full Wave category

​Go Average Load Current of Three Phase Uncontrolled Rectifier
IL(avg)=33nVmax2πRL
​Go Power Delivered to Load in Three Phase Uncontrolled Rectifier
Pout=VacVdc
​Go RMS Load Current of Three Phase Uncontrolled Rectifier
IL(rms)=nVmaxRL21+332π
​Go Average Diode Current of Three Phase Uncontrolled Rectifier
Id(avg)=3nVmax2πRL

How to Evaluate Load Voltage of Full Wave Three Phase Uncontrolled Rectifier?

Load Voltage of Full Wave Three Phase Uncontrolled Rectifier evaluator uses AC Voltage = (2*Winding Ratio*Peak Input Voltage)/pi to evaluate the AC Voltage, Load Voltage of Full Wave Three Phase Uncontrolled Rectifier is the average value of the rectified sinusoidal waveform. The average load voltage of a full-wave three-phase uncontrolled rectifier is also known as the DC output voltage. It is the voltage that is available to the load circuit. It is important to note that the DC output voltage of a full-wave three-phase uncontrolled rectifier is not perfectly constant. It will have a ripple voltage superimposed on it. The ripple voltage is caused by the fact that the rectified sinusoidal waveform is not a pure DC waveform. AC Voltage is denoted by Vac symbol.

How to evaluate Load Voltage of Full Wave Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for Load Voltage of Full Wave Three Phase Uncontrolled Rectifier, enter Winding Ratio (n) & Peak Input Voltage (Vmax) and hit the calculate button.

FAQs on Load Voltage of Full Wave Three Phase Uncontrolled Rectifier

What is the formula to find Load Voltage of Full Wave Three Phase Uncontrolled Rectifier?
The formula of Load Voltage of Full Wave Three Phase Uncontrolled Rectifier is expressed as AC Voltage = (2*Winding Ratio*Peak Input Voltage)/pi. Here is an example- 2100.845 = (2*15*220)/pi.
How to calculate Load Voltage of Full Wave Three Phase Uncontrolled Rectifier?
With Winding Ratio (n) & Peak Input Voltage (Vmax) we can find Load Voltage of Full Wave Three Phase Uncontrolled Rectifier using the formula - AC Voltage = (2*Winding Ratio*Peak Input Voltage)/pi. This formula also uses Archimedes' constant .
Can the Load Voltage of Full Wave Three Phase Uncontrolled Rectifier be negative?
No, the Load Voltage of Full Wave Three Phase Uncontrolled Rectifier, measured in Electric Potential cannot be negative.
Which unit is used to measure Load Voltage of Full Wave Three Phase Uncontrolled Rectifier?
Load Voltage of Full Wave Three Phase Uncontrolled Rectifier is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Load Voltage of Full Wave Three Phase Uncontrolled Rectifier can be measured.
Copied!