Fx Copy
LaTeX Copy
The load impedance is defined as the impedance of the load of the Transmission line during transient. Check FAQs
Il=Z01-ρiρi-1
Il - Load Impedance?Z0 - Characteristic Impedance?ρi - Reflection Coefficient of Current?

Load Impedance using Reflected Coefficient of Current Example

With values
With units
Only example

Here is how the Load Impedance using Reflected Coefficient of Current equation looks like with Values.

Here is how the Load Impedance using Reflected Coefficient of Current equation looks like with Units.

Here is how the Load Impedance using Reflected Coefficient of Current equation looks like.

-55.5Edit=55.5Edit1-8Edit8Edit-1
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Impedance using Reflected Coefficient of Current

Load Impedance using Reflected Coefficient of Current Solution

Follow our step by step solution on how to calculate Load Impedance using Reflected Coefficient of Current?

FIRST Step Consider the formula
Il=Z01-ρiρi-1
Next Step Substitute values of Variables
Il=55.5Ω1-88-1
Next Step Prepare to Evaluate
Il=55.51-88-1
LAST Step Evaluate
Il=-55.5Ω

Load Impedance using Reflected Coefficient of Current Formula Elements

Variables
Load Impedance
The load impedance is defined as the impedance of the load of the Transmission line during transient.
Symbol: Il
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Characteristic Impedance
The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
Symbol: Z0
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Reflection Coefficient of Current
Reflection Coefficient Of Current is defined as the ratio of the reflected current to the incident current of the Transmission line.
Symbol: ρi
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Load Impedance

​Go Load Impedance using Reflected Coefficient of Voltage
Il=Z0ρv+11-ρv
​Go Load Impedance using Reflected Current
Il=Z0Vi+ErEr-Vi
​Go Load Impedance for Transmitted Waves
Il=VtIt
​Go Load Impedance using Transmitted Voltage
Il=VtZ02Vi-Vt

Other formulas in Transient category

​Go Characteristic Impedance (Line SC)
Z0=ViIi
​Go Incident Voltage using Transmitted Voltage (Load OC)
Vi=Vt2
​Go Reflection Coefficient for Voltage
ρv=ErVi
​Go Reflected Voltage using Reflection Coefficient of Voltage
Er=ρvVi

How to Evaluate Load Impedance using Reflected Coefficient of Current?

Load Impedance using Reflected Coefficient of Current evaluator uses Load Impedance = Characteristic Impedance*(1-Reflection Coefficient of Current)/(Reflection Coefficient of Current-1) to evaluate the Load Impedance, The Load Impedance using Reflected Coefficient of Current formula is defined as the apparent opposition in an electrical circuit to the flow of an alternating current that is analogous to the actual electrical resistance to a direct current and that is the ratio of effective electromotive force to the effective current. Load Impedance is denoted by Il symbol.

How to evaluate Load Impedance using Reflected Coefficient of Current using this online evaluator? To use this online evaluator for Load Impedance using Reflected Coefficient of Current, enter Characteristic Impedance (Z0) & Reflection Coefficient of Current i) and hit the calculate button.

FAQs on Load Impedance using Reflected Coefficient of Current

What is the formula to find Load Impedance using Reflected Coefficient of Current?
The formula of Load Impedance using Reflected Coefficient of Current is expressed as Load Impedance = Characteristic Impedance*(1-Reflection Coefficient of Current)/(Reflection Coefficient of Current-1). Here is an example- -55.5 = 55.5*(1-8)/(8-1).
How to calculate Load Impedance using Reflected Coefficient of Current?
With Characteristic Impedance (Z0) & Reflection Coefficient of Current i) we can find Load Impedance using Reflected Coefficient of Current using the formula - Load Impedance = Characteristic Impedance*(1-Reflection Coefficient of Current)/(Reflection Coefficient of Current-1).
What are the other ways to Calculate Load Impedance?
Here are the different ways to Calculate Load Impedance-
  • Load Impedance=Characteristic Impedance*(Reflection Coefficient of Voltage+1)/(1-Reflection Coefficient of Voltage)OpenImg
  • Load Impedance=Characteristic Impedance*(Incident Voltage+Reflected Voltage)/(Reflected Voltage-Incident Voltage)OpenImg
  • Load Impedance=Transmitted Voltage/Transmitted CurrentOpenImg
Can the Load Impedance using Reflected Coefficient of Current be negative?
Yes, the Load Impedance using Reflected Coefficient of Current, measured in Electric Resistance can be negative.
Which unit is used to measure Load Impedance using Reflected Coefficient of Current?
Load Impedance using Reflected Coefficient of Current is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Load Impedance using Reflected Coefficient of Current can be measured.
Copied!