Current Underground AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=VPloss3.53ρ(L2)
I - Current Underground AC?V - Volume Of Conductor?Ploss - Line Losses?ρ - Resistivity?L - Length of Underground AC Wire?

Load Current using Volume of Conductor Material (3 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Load Current using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like with Values.

Here is how the Load Current using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like with Units.

Here is how the Load Current using Volume of Conductor Material (3 Phase 4 Wire US) equation looks like.

39.4731Edit=60Edit2.67Edit3.531.7E-5Edit(24Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Volume of Conductor Material (3 Phase 4 Wire US)

Load Current using Volume of Conductor Material (3 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Load Current using Volume of Conductor Material (3 Phase 4 Wire US)?

FIRST Step Consider the formula
I=VPloss3.53ρ(L2)
Next Step Substitute values of Variables
I=602.67W3.531.7E-5Ω*m(24m2)
Next Step Prepare to Evaluate
I=602.673.531.7E-5(242)
Next Step Evaluate
I=39.4730699249466A
LAST Step Rounding Answer
I=39.4731A

Load Current using Volume of Conductor Material (3 Phase 4 Wire US) Formula Elements

Variables
Functions
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Underground AC

​Go Load Current (3 Phase 4 Wire US)
I=6P3Vmcos(Φ)
​Go Load Current using Line Losses (3 Phase 4 Wire US)
I=Ploss2R

Other formulas in Current and Voltage category

​Go Maximum Voltage using Volume of Conductor Material (3 Phase 4 Wire US)
Vm=7ρ(PL)2PlossV(cos(Φ))2
​Go Maximum Voltage using Load Current (3 Phase 4 Wire US)
Vm=6P3cos(Φ)I
​Go Maximum Voltage using Area of X-Section (3 Phase 4 Wire US)
Vm=(Pcos(Φ))2ρLPlossA
​Go Maximum Voltage using Line Losses (3 Phase 4 Wire US)
Vm=(2Pcos(Φ))RPloss

How to Evaluate Load Current using Volume of Conductor Material (3 Phase 4 Wire US)?

Load Current using Volume of Conductor Material (3 Phase 4 Wire US) evaluator uses Current Underground AC = sqrt((Volume Of Conductor*Line Losses)/(3.5*3*Resistivity*(Length of Underground AC Wire^2))) to evaluate the Current Underground AC, The Load Current using Volume of Conductor Material (3 phase 4 wire US) formula is defined as the current that flows into the load of the three-phase four-wire underground system. Current Underground AC is denoted by I symbol.

How to evaluate Load Current using Volume of Conductor Material (3 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Load Current using Volume of Conductor Material (3 Phase 4 Wire US), enter Volume Of Conductor (V), Line Losses (Ploss), Resistivity (ρ) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Load Current using Volume of Conductor Material (3 Phase 4 Wire US)

What is the formula to find Load Current using Volume of Conductor Material (3 Phase 4 Wire US)?
The formula of Load Current using Volume of Conductor Material (3 Phase 4 Wire US) is expressed as Current Underground AC = sqrt((Volume Of Conductor*Line Losses)/(3.5*3*Resistivity*(Length of Underground AC Wire^2))). Here is an example- 39.47307 = sqrt((60*2.67)/(3.5*3*1.7E-05*(24^2))).
How to calculate Load Current using Volume of Conductor Material (3 Phase 4 Wire US)?
With Volume Of Conductor (V), Line Losses (Ploss), Resistivity (ρ) & Length of Underground AC Wire (L) we can find Load Current using Volume of Conductor Material (3 Phase 4 Wire US) using the formula - Current Underground AC = sqrt((Volume Of Conductor*Line Losses)/(3.5*3*Resistivity*(Length of Underground AC Wire^2))). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Current Underground AC?
Here are the different ways to Calculate Current Underground AC-
  • Current Underground AC=(sqrt(6)*Power Transmitted)/(3*Maximum Voltage Underground AC*cos(Phase Difference))OpenImg
  • Current Underground AC=sqrt(Line Losses/2*Resistance Underground AC)OpenImg
Can the Load Current using Volume of Conductor Material (3 Phase 4 Wire US) be negative?
Yes, the Load Current using Volume of Conductor Material (3 Phase 4 Wire US), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Volume of Conductor Material (3 Phase 4 Wire US)?
Load Current using Volume of Conductor Material (3 Phase 4 Wire US) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Volume of Conductor Material (3 Phase 4 Wire US) can be measured.
Copied!