Current underground DC is defined as the current flowing through the overhead ac supply wire. Check FAQs
C1=Pline2R1
C1 - Current underground DC?Pline - Line Losses?R1 - Resistance underground DC?

Load Current using Line Losses (DC Three-Wire US) Example

With values
With units
Only example

Here is how the Load Current using Line Losses (DC Three-Wire US) equation looks like with Values.

Here is how the Load Current using Line Losses (DC Three-Wire US) equation looks like with Units.

Here is how the Load Current using Line Losses (DC Three-Wire US) equation looks like.

0.2449Edit=0.6Edit25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Line Losses (DC Three-Wire US)

Load Current using Line Losses (DC Three-Wire US) Solution

Follow our step by step solution on how to calculate Load Current using Line Losses (DC Three-Wire US)?

FIRST Step Consider the formula
C1=Pline2R1
Next Step Substitute values of Variables
C1=0.6W25Ω
Next Step Prepare to Evaluate
C1=0.625
Next Step Evaluate
C1=0.244948974278318A
LAST Step Rounding Answer
C1=0.2449A

Load Current using Line Losses (DC Three-Wire US) Formula Elements

Variables
Functions
Current underground DC
Current underground DC is defined as the current flowing through the overhead ac supply wire.
Symbol: C1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistance underground DC
Resistance underground DC is defined as the time rate of flow of charge through a cross-sectional area.
Symbol: R1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current underground DC

​Go Load Current Per Phase (3-Phase 3-Wire US)
C1=6P3Vmcos(θ)
​Go Current using Line Losses (3-Phase 3-Wire US)
C1=Pline3R1

Other formulas in Current and Voltage category

​Go Maximum Voltage using Volume of Conductor Material(DC Three-Wire US)
Vm=5ρ(Pl)2PlineV
​Go Maximum Voltage using Area of X-Section (DC Three-Wire US)
Vm=2(P2)ρlPlineA
​Go Maximum Voltage using Line Losses (DC Three-Wire US)
Vm=2(P2)R1Pline
​Go Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US)
Vm=6ρ(Pl)2PlineV(cos(θ))2

How to Evaluate Load Current using Line Losses (DC Three-Wire US)?

Load Current using Line Losses (DC Three-Wire US) evaluator uses Current underground DC = sqrt(Line Losses/(2*Resistance underground DC)) to evaluate the Current underground DC, The Load Current using Line Losses (DC Three-Wire US) formula is defined as the current that flows into the load of the DC Three-Wire underground system. Current underground DC is denoted by C1 symbol.

How to evaluate Load Current using Line Losses (DC Three-Wire US) using this online evaluator? To use this online evaluator for Load Current using Line Losses (DC Three-Wire US), enter Line Losses (Pline) & Resistance underground DC (R1) and hit the calculate button.

FAQs on Load Current using Line Losses (DC Three-Wire US)

What is the formula to find Load Current using Line Losses (DC Three-Wire US)?
The formula of Load Current using Line Losses (DC Three-Wire US) is expressed as Current underground DC = sqrt(Line Losses/(2*Resistance underground DC)). Here is an example- 0.244949 = sqrt(0.6/(2*5)).
How to calculate Load Current using Line Losses (DC Three-Wire US)?
With Line Losses (Pline) & Resistance underground DC (R1) we can find Load Current using Line Losses (DC Three-Wire US) using the formula - Current underground DC = sqrt(Line Losses/(2*Resistance underground DC)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Current underground DC?
Here are the different ways to Calculate Current underground DC-
  • Current underground DC=(sqrt(6)*Power Transmitted)/(3*Maximum Voltage*cos(Theta))OpenImg
  • Current underground DC=sqrt(Line Losses/(3*Resistance underground DC))OpenImg
Can the Load Current using Line Losses (DC Three-Wire US) be negative?
Yes, the Load Current using Line Losses (DC Three-Wire US), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Line Losses (DC Three-Wire US)?
Load Current using Line Losses (DC Three-Wire US) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Line Losses (DC Three-Wire US) can be measured.