Current Underground AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=Ploss2R
I - Current Underground AC?Ploss - Line Losses?R - Resistance Underground AC?

Load Current using Line Losses (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Load Current using Line Losses (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Load Current using Line Losses (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Load Current using Line Losses (2 Phase 4 Wire US) equation looks like.

2.5836Edit=2.67Edit25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Line Losses (2 Phase 4 Wire US)

Load Current using Line Losses (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Load Current using Line Losses (2 Phase 4 Wire US)?

FIRST Step Consider the formula
I=Ploss2R
Next Step Substitute values of Variables
I=2.67W25Ω
Next Step Prepare to Evaluate
I=2.6725
Next Step Evaluate
I=2.58360213655276A
LAST Step Rounding Answer
I=2.5836A

Load Current using Line Losses (2 Phase 4 Wire US) Formula Elements

Variables
Functions
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Underground AC

​Go Load Current using Area of X-Section (2 Phase 4 Wire US)
I=PlossA2ρL
​Go Load Current using Volume of Conductor Material (2 Phase 4 Wire US)
I=VPloss4ρ(L2)
​Go Load Current (2 Phase 4 Wire US)
I=2PVmcos(Φ)

Other formulas in Current and Voltage category

​Go Maximum Voltage using Area of X-Section (2 Phase 4 Wire US)
Vm=(2Pcos(Φ))ρLPlossA
​Go RMS Voltage using Area of X-Section (2 Phase 4 Wire US)
Vrms=(Pcos(Φ))ρLPlossA
​Go Maximum Voltage using Line Losses (2 Phase 4 Wire US)
Vm=(2Pcos(Φ))RPloss
​Go RMS Voltage using Line Losses (2 Phase 4 Wire US)
Vrms=(Pcos(Φ))RPloss

How to Evaluate Load Current using Line Losses (2 Phase 4 Wire US)?

Load Current using Line Losses (2 Phase 4 Wire US) evaluator uses Current Underground AC = sqrt(Line Losses/2*Resistance Underground AC) to evaluate the Current Underground AC, The Load Current using Line Losses (2 phase 4 wire US) formula is defined as the current that flows into the load of the two-phase three-wire underground system. Current Underground AC is denoted by I symbol.

How to evaluate Load Current using Line Losses (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Load Current using Line Losses (2 Phase 4 Wire US), enter Line Losses (Ploss) & Resistance Underground AC (R) and hit the calculate button.

FAQs on Load Current using Line Losses (2 Phase 4 Wire US)

What is the formula to find Load Current using Line Losses (2 Phase 4 Wire US)?
The formula of Load Current using Line Losses (2 Phase 4 Wire US) is expressed as Current Underground AC = sqrt(Line Losses/2*Resistance Underground AC). Here is an example- 2.583602 = sqrt(2.67/2*5).
How to calculate Load Current using Line Losses (2 Phase 4 Wire US)?
With Line Losses (Ploss) & Resistance Underground AC (R) we can find Load Current using Line Losses (2 Phase 4 Wire US) using the formula - Current Underground AC = sqrt(Line Losses/2*Resistance Underground AC). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Current Underground AC?
Here are the different ways to Calculate Current Underground AC-
  • Current Underground AC=sqrt(Line Losses*Area of Underground AC Wire/(2*Resistivity*Length of Underground AC Wire))OpenImg
  • Current Underground AC=sqrt(Volume Of Conductor*Line Losses/(4*Resistivity*(Length of Underground AC Wire^2)))OpenImg
  • Current Underground AC=sqrt(2)*Power Transmitted/(Maximum Voltage Underground AC*cos(Phase Difference))OpenImg
Can the Load Current using Line Losses (2 Phase 4 Wire US) be negative?
Yes, the Load Current using Line Losses (2 Phase 4 Wire US), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Line Losses (2 Phase 4 Wire US)?
Load Current using Line Losses (2 Phase 4 Wire US) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Line Losses (2 Phase 4 Wire US) can be measured.