Current Overhead AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=PlossA4ρL
I - Current Overhead AC?Ploss - Line Losses?A - Area of Overhead AC Wire?ρ - Resistivity?L - Length of Overhead AC Wire?

Load Current using Line Losses (2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Load Current using Line Losses (2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Load Current using Line Losses (2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Load Current using Line Losses (2-Phase 4-Wire OS) equation looks like.

94.8402Edit=8.23Edit0.79Edit41.7E-5Edit10.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Line Losses (2-Phase 4-Wire OS)

Load Current using Line Losses (2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Load Current using Line Losses (2-Phase 4-Wire OS)?

FIRST Step Consider the formula
I=PlossA4ρL
Next Step Substitute values of Variables
I=8.23W0.7941.7E-5Ω*m10.63m
Next Step Prepare to Evaluate
I=8.230.7941.7E-510.63
Next Step Evaluate
I=94.8401811070073A
LAST Step Rounding Answer
I=94.8402A

Load Current using Line Losses (2-Phase 4-Wire OS) Formula Elements

Variables
Functions
Current Overhead AC
Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Overhead AC

​Go Load Current(2-Phase 4-Wire OS)
I=P22Vmcos(Φ)
​Go Load Current using Area of X-Section(2-Phase 4-Wire OS)
I=PlossA(32)ρL

Other formulas in Current and Voltage category

​Go Maximum Voltage(2-Phase 4-Wire OS)
Vm=(2)Vac
​Go Maximum Voltage using Area of X-Section(2-Phase 4-Wire OS)
Vm=Lρ(P2)2APloss((cos(Φ))2)
​Go RMS Voltage using Area of X-Section(2-Phase 4-Wire OS)
Vrms=Lρ(P2)APloss((cos(Φ))2)
​Go Maximum Voltage using Load Current (2-Phase 4-Wire OS)
Vm=P2(2)I(cos(Φ))

How to Evaluate Load Current using Line Losses (2-Phase 4-Wire OS)?

Load Current using Line Losses (2-Phase 4-Wire OS) evaluator uses Current Overhead AC = sqrt(Line Losses*Area of Overhead AC Wire/(4*Resistivity*Length of Overhead AC Wire)) to evaluate the Current Overhead AC, The Load Current using Line Losses (2-Phase 4-Wire OS) formula is defined as the current that flows into the load of the one-phase two-wire underground system. Current Overhead AC is denoted by I symbol.

How to evaluate Load Current using Line Losses (2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Load Current using Line Losses (2-Phase 4-Wire OS), enter Line Losses (Ploss), Area of Overhead AC Wire (A), Resistivity (ρ) & Length of Overhead AC Wire (L) and hit the calculate button.

FAQs on Load Current using Line Losses (2-Phase 4-Wire OS)

What is the formula to find Load Current using Line Losses (2-Phase 4-Wire OS)?
The formula of Load Current using Line Losses (2-Phase 4-Wire OS) is expressed as Current Overhead AC = sqrt(Line Losses*Area of Overhead AC Wire/(4*Resistivity*Length of Overhead AC Wire)). Here is an example- 94.84018 = sqrt(8.23*0.79/(4*1.7E-05*10.63)).
How to calculate Load Current using Line Losses (2-Phase 4-Wire OS)?
With Line Losses (Ploss), Area of Overhead AC Wire (A), Resistivity (ρ) & Length of Overhead AC Wire (L) we can find Load Current using Line Losses (2-Phase 4-Wire OS) using the formula - Current Overhead AC = sqrt(Line Losses*Area of Overhead AC Wire/(4*Resistivity*Length of Overhead AC Wire)). This formula also uses Square Root Function function(s).
What are the other ways to Calculate Current Overhead AC?
Here are the different ways to Calculate Current Overhead AC-
  • Current Overhead AC=Power Transmitted/(2*sqrt(2)*Maximum Voltage Overhead AC*cos(Phase Difference))OpenImg
  • Current Overhead AC=sqrt(Line Losses*Area of Overhead AC Wire/((32)*Resistivity*Length of Overhead AC Wire))OpenImg
Can the Load Current using Line Losses (2-Phase 4-Wire OS) be negative?
Yes, the Load Current using Line Losses (2-Phase 4-Wire OS), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Line Losses (2-Phase 4-Wire OS)?
Load Current using Line Losses (2-Phase 4-Wire OS) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Line Losses (2-Phase 4-Wire OS) can be measured.
Copied!