Current Underground AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=Ploss2R
I - Current Underground AC?Ploss - Line Losses?R - Resistance Underground AC?

Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

0.5167Edit=2.67Edit25Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)

Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
I=Ploss2R
Next Step Substitute values of Variables
I=2.67W25Ω
Next Step Prepare to Evaluate
I=2.6725
Next Step Evaluate
I=0.516720427310553A
LAST Step Rounding Answer
I=0.5167A

Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Functions
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Underground AC

​Go Load Current (1-Phase 2-Wire Mid-Point Earthed)
I=2PVmcos(Φ)

Other formulas in Current and Voltage category

​Go Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Vm=2PIcos(Φ)
​Go RMS Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Vrms=PIcos(Φ)
​Go Maximum Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))RPloss
​Go Maximum Voltage using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))ρLAPloss

How to Evaluate Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)?

Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Current Underground AC = sqrt(Line Losses/(2*Resistance Underground AC)) to evaluate the Current Underground AC, The Load Current using Line Losses (1-phase 2-wire Mid-point Earthed) formula is defined as the current that flows into the load of the single-phase two-wire mid-point earthed underground system. Current Underground AC is denoted by I symbol.

How to evaluate Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed), enter Line Losses (Ploss) & Resistance Underground AC (R) and hit the calculate button.

FAQs on Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) is expressed as Current Underground AC = sqrt(Line Losses/(2*Resistance Underground AC)). Here is an example- 0.51672 = sqrt(2.67/(2*5)).
How to calculate Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)?
With Line Losses (Ploss) & Resistance Underground AC (R) we can find Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) using the formula - Current Underground AC = sqrt(Line Losses/(2*Resistance Underground AC)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Current Underground AC?
Here are the different ways to Calculate Current Underground AC-
  • Current Underground AC=(sqrt(2)*Power Transmitted)/(Maximum Voltage Underground AC*cos(Phase Difference))OpenImg
Can the Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) be negative?
Yes, the Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)?
Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!