Current Underground AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=PlossAρL2
I - Current Underground AC?Ploss - Line Losses?A - Area of Underground AC Wire?ρ - Resistivity?L - Length of Underground AC Wire?

Load Current using Area of X-section (1 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Load Current using Area of X-section (1 Phase 3 Wire US) equation looks like with Values.

Here is how the Load Current using Area of X-section (1 Phase 3 Wire US) equation looks like with Units.

Here is how the Load Current using Area of X-section (1 Phase 3 Wire US) equation looks like.

64.7166Edit=2.67Edit1.28Edit1.7E-5Edit24Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current using Area of X-section (1 Phase 3 Wire US)

Load Current using Area of X-section (1 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Load Current using Area of X-section (1 Phase 3 Wire US)?

FIRST Step Consider the formula
I=PlossAρL2
Next Step Substitute values of Variables
I=2.67W1.281.7E-5Ω*m24m2
Next Step Prepare to Evaluate
I=2.671.281.7E-5242
Next Step Evaluate
I=64.7165766563533A
LAST Step Rounding Answer
I=64.7166A

Load Current using Area of X-section (1 Phase 3 Wire US) Formula Elements

Variables
Functions
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Underground AC

​Go Load Current using Line Losses (1 Phase 3 Wire US)
I=Ploss2R

Other formulas in Current and Voltage category

​Go Maximum Voltage using Volume of Conductor Material(1 Phase 3 Wire US)
Vm=10ρ(PL)2PlossV(cos(Φ))2
​Go RMS Voltage using Volume of Conductor Material(1 Phase 3 Wire US)
Vrms=5ρ(PL)2PlossV((cos(Φ))2)
​Go Maximum Voltage using Load Current (1 Phase 3 Wire US)
Vm=2Pcos(Φ)I
​Go RMS Voltage using Load Current (1 Phase 3 Wire US)
Vrms=2Pcos(Φ)I

How to Evaluate Load Current using Area of X-section (1 Phase 3 Wire US)?

Load Current using Area of X-section (1 Phase 3 Wire US) evaluator uses Current Underground AC = sqrt((Line Losses*Area of Underground AC Wire)/(Resistivity*Length of Underground AC Wire*2)) to evaluate the Current Underground AC, The Load Current using Area of X-section (1 phase 3 wire US) formula is defined as the current that flows into the load of the single-phase two-wire underground system. Current Underground AC is denoted by I symbol.

How to evaluate Load Current using Area of X-section (1 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Load Current using Area of X-section (1 Phase 3 Wire US), enter Line Losses (Ploss), Area of Underground AC Wire (A), Resistivity (ρ) & Length of Underground AC Wire (L) and hit the calculate button.

FAQs on Load Current using Area of X-section (1 Phase 3 Wire US)

What is the formula to find Load Current using Area of X-section (1 Phase 3 Wire US)?
The formula of Load Current using Area of X-section (1 Phase 3 Wire US) is expressed as Current Underground AC = sqrt((Line Losses*Area of Underground AC Wire)/(Resistivity*Length of Underground AC Wire*2)). Here is an example- 64.71658 = sqrt((2.67*1.28)/(1.7E-05*24*2)).
How to calculate Load Current using Area of X-section (1 Phase 3 Wire US)?
With Line Losses (Ploss), Area of Underground AC Wire (A), Resistivity (ρ) & Length of Underground AC Wire (L) we can find Load Current using Area of X-section (1 Phase 3 Wire US) using the formula - Current Underground AC = sqrt((Line Losses*Area of Underground AC Wire)/(Resistivity*Length of Underground AC Wire*2)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Current Underground AC?
Here are the different ways to Calculate Current Underground AC-
  • Current Underground AC=sqrt(Line Losses/2*Resistance Underground AC)OpenImg
Can the Load Current using Area of X-section (1 Phase 3 Wire US) be negative?
Yes, the Load Current using Area of X-section (1 Phase 3 Wire US), measured in Electric Current can be negative.
Which unit is used to measure Load Current using Area of X-section (1 Phase 3 Wire US)?
Load Current using Area of X-section (1 Phase 3 Wire US) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current using Area of X-section (1 Phase 3 Wire US) can be measured.
Copied!