Fx Copy
LaTeX Copy
Load current refers to the current that is drawn by the external load connected to the generator's output terminals. The current flows through load and returns to generator via armature winding. Check FAQs
IL=PoutVt
IL - Load Current?Pout - Output Power?Vt - Terminal Voltage?

Load Current of Series DC Generator given Output Power Example

With values
With units
Only example

Here is how the Load Current of Series DC Generator given Output Power equation looks like with Values.

Here is how the Load Current of Series DC Generator given Output Power equation looks like with Units.

Here is how the Load Current of Series DC Generator given Output Power equation looks like.

0.8824Edit=150Edit170Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Load Current of Series DC Generator given Output Power

Load Current of Series DC Generator given Output Power Solution

Follow our step by step solution on how to calculate Load Current of Series DC Generator given Output Power?

FIRST Step Consider the formula
IL=PoutVt
Next Step Substitute values of Variables
IL=150W170V
Next Step Prepare to Evaluate
IL=150170
Next Step Evaluate
IL=0.882352941176471A
LAST Step Rounding Answer
IL=0.8824A

Load Current of Series DC Generator given Output Power Formula Elements

Variables
Load Current
Load current refers to the current that is drawn by the external load connected to the generator's output terminals. The current flows through load and returns to generator via armature winding.
Symbol: IL
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Output Power
Output Power refers to the product of current and voltage at the output terminal of a dc generator.
Symbol: Pout
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Terminal Voltage
Terminal Voltage, electric pressure or electric tension is the difference in electric potential between two points in electrical machines.
Symbol: Vt
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Load Current

​Go Load Current of Series DC Generator given Load Power
IL=PLVt

Other formulas in Current category

​Go Armature Current of Series DC Generator given Output Power
Ia=Pconv-PoutRa
​Go Armature Current of Series DC Generator using Terminal Voltage
Ia=Va-VtRse+Ra
​Go Armature Current of Series DC Generator given Torque
Ia=τωsVa

How to Evaluate Load Current of Series DC Generator given Output Power?

Load Current of Series DC Generator given Output Power evaluator uses Load Current = Output Power/Terminal Voltage to evaluate the Load Current, The Load Current of Series DC Generator given Output Power formula is defined as the load current refers to the current that is drawn by the external load connected to the generator's output terminals. The current flows through load and returns to generator via armature winding. Load Current is denoted by IL symbol.

How to evaluate Load Current of Series DC Generator given Output Power using this online evaluator? To use this online evaluator for Load Current of Series DC Generator given Output Power, enter Output Power (Pout) & Terminal Voltage (Vt) and hit the calculate button.

FAQs on Load Current of Series DC Generator given Output Power

What is the formula to find Load Current of Series DC Generator given Output Power?
The formula of Load Current of Series DC Generator given Output Power is expressed as Load Current = Output Power/Terminal Voltage. Here is an example- 0.882353 = 150/170.
How to calculate Load Current of Series DC Generator given Output Power?
With Output Power (Pout) & Terminal Voltage (Vt) we can find Load Current of Series DC Generator given Output Power using the formula - Load Current = Output Power/Terminal Voltage.
What are the other ways to Calculate Load Current?
Here are the different ways to Calculate Load Current-
  • Load Current=Load Power/Terminal VoltageOpenImg
Can the Load Current of Series DC Generator given Output Power be negative?
No, the Load Current of Series DC Generator given Output Power, measured in Electric Current cannot be negative.
Which unit is used to measure Load Current of Series DC Generator given Output Power?
Load Current of Series DC Generator given Output Power is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current of Series DC Generator given Output Power can be measured.
Copied!