Current Underground AC is defined as the current flowing through the overhead ac supply wire. Check FAQs
I=2PVmcos(Φ)
I - Current Underground AC?P - Power Transmitted?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?

Load Current (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

2.13Edit=2300Edit230Editcos(30Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Load Current (1-Phase 2-Wire Mid-Point Earthed)

Load Current (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Load Current (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
I=2PVmcos(Φ)
Next Step Substitute values of Variables
I=2300W230Vcos(30°)
Next Step Convert Units
I=2300W230Vcos(0.5236rad)
Next Step Prepare to Evaluate
I=2300230cos(0.5236)
Next Step Evaluate
I=2.12999108068102A
LAST Step Rounding Answer
I=2.13A

Load Current (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Functions
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Current Underground AC

​Go Load Current using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
I=Ploss2R

Other formulas in Current and Voltage category

​Go Maximum Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Vm=2PIcos(Φ)
​Go RMS Voltage using Load Current (1-Phase 2-Wire Mid-Point Earthed)
Vrms=PIcos(Φ)
​Go Maximum Voltage using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))RPloss
​Go Maximum Voltage using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
Vm=(2Pcos(Φ))ρLAPloss

How to Evaluate Load Current (1-Phase 2-Wire Mid-Point Earthed)?

Load Current (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Current Underground AC = (sqrt(2)*Power Transmitted)/(Maximum Voltage Underground AC*cos(Phase Difference)) to evaluate the Current Underground AC, The Load Current (1-phase 2-wire Mid-point Earthed) formula is defined as the current that flows into the load of the single-phase two-wire mid-point earthed underground system. Current Underground AC is denoted by I symbol.

How to evaluate Load Current (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Load Current (1-Phase 2-Wire Mid-Point Earthed), enter Power Transmitted (P), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ) and hit the calculate button.

FAQs on Load Current (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Load Current (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Load Current (1-Phase 2-Wire Mid-Point Earthed) is expressed as Current Underground AC = (sqrt(2)*Power Transmitted)/(Maximum Voltage Underground AC*cos(Phase Difference)). Here is an example- 2.129991 = (sqrt(2)*300)/(230*cos(0.5235987755982)).
How to calculate Load Current (1-Phase 2-Wire Mid-Point Earthed)?
With Power Transmitted (P), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ) we can find Load Current (1-Phase 2-Wire Mid-Point Earthed) using the formula - Current Underground AC = (sqrt(2)*Power Transmitted)/(Maximum Voltage Underground AC*cos(Phase Difference)). This formula also uses Cosine, Square Root Function function(s).
What are the other ways to Calculate Current Underground AC?
Here are the different ways to Calculate Current Underground AC-
  • Current Underground AC=sqrt(Line Losses/(2*Resistance Underground AC))OpenImg
Can the Load Current (1-Phase 2-Wire Mid-Point Earthed) be negative?
Yes, the Load Current (1-Phase 2-Wire Mid-Point Earthed), measured in Electric Current can be negative.
Which unit is used to measure Load Current (1-Phase 2-Wire Mid-Point Earthed)?
Load Current (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Load Current (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!